13 research outputs found

    Perioperative Levosimendan Infusion in Patients With End-Stage Heart Failure Undergoing Left Ventricular Assist Device Implantation

    Get PDF
    Left ventricular assist device (LVAD) therapy has been instrumental in saving lives of patients with end-stage heart failure (HF). Recent generation devices have short-to-mid-term survival rates close to heart transplantation. Unfortunately, up to 1 in 4 patients develop a life-threatening right-sided HF (RHF) early post LVAD implantation, with high morbidity and mortality rate, necessitating prolonged ICU stay, prolonged inotropic support, and implantation of a right-ventricular assist device. Pre-operative optimization of HF therapy could help in prevention, and/or mitigation of RHF. Levosimendan (LEVO) is a non-conventional inotropic agent that works by amplifying calcium sensitivity of troponin C in cardiac myocytes, without increasing the intra-cellular calcium or exacerbating ischemia. LEVO acts as an inodilator, which reduces the cardiac pre-, and after-load. LEVO administration is associated with hemodynamic improvements. Despite decades long of the use of LVAD and more than two decades of the use of LEVO for HF, the literature on LEVO use in LVAD is very limited. In this paper, we sought to conduct a systematic review to synthesize evidence related to the use of LEVO for the mitigation and/or prevention of RHF in patients undergoing LVAD implantation

    The effect of iterative model reconstruction on coronary artery calcium quantification

    Get PDF
    Coronary artery calcium (CAC) scoring with computed tomography (CT) is an established tool for quantifying calcified atherosclerotic plaque burden. Despite the widespread use of novel image reconstruction techniques in CT, the effect of iterative model reconstruction on CAC score remains unclear. We sought to assess the impact of iterative model based reconstruction (IMR) on coronary artery calcium quantification as compared to the standard filtered back projection (FBP) algorithm and hybrid iterative reconstruction (HIR). In addition, we aimed to simulate the impact of iterative reconstruction techniques on calcium scoring based risk stratification of a larger asymptomatic population. We studied 63 individuals who underwent CAC scoring. Images were reconstructed with FBP, HIR and IMR and CAC scores were measured. We estimated the cardiovascular risk reclassification rate of IMR versus HIR and FBP in a larger asymptomatic population (n = 504). The median CAC scores were 147.7 (IQR 9.6-582.9), 107.0 (IQR 5.9-526.6) and 115.1 (IQR 9.3-508.3) for FBP, HIR and IMR, respectively. The HIR and IMR resulted in lower CAC scores as compared to FBP (both p < 0.001), however there was no difference between HIR and IMR (p = 0.855). The CAC score decreased by 7.2 % in HIR and 7.3 % in IMR as compared to FBP, resulting in a risk reclassification rate of 2.4 % for both HIR and IMR. The utilization of IMR for CAC scoring reduces the measured calcium quantity. However, the CAC score based risk stratification demonstrated modest reclassification in IMR and HIR versus FBP

    Quantitative aortography for assessment of aortic regurgitation in the era of percutaneous aortic valve replacement

    Get PDF
    Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries

    Quantitative aortography for assessment of aortic regurgitation in the era of percutaneous aortic valve replacement

    Get PDF
    Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR &gt; 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries

    Temporary Right Ventricular Assist Devices: A Systematic Review

    Get PDF
    Acute right-sided heart failure (RHF) is a complex clinical syndrome, with a wide range of clinical presentations, associated with increased mortality and morbidity, but about which there is a scarcity of evidence-based literature. A temporary right ventricular assist device (t-RVAD) is a potential treatment option for selected patients with severe right ventricular dysfunction as a bridge-to-recovery or as a permanent solution. We sought to conduct a systematic review to determine the safety and efficacy of t-RVAD implantation. Thirty-one studies met the inclusion criteria, from which data were extracted. Successful t-RVAD weaning ranged between 23% and 100%. Moreover, 30-day survival post-temporary RAVD implantation ranged from 46% to 100%. Bleeding, acute kidney injury, stroke, and device malfunction were the most commonly reported complications. Notwithstanding this, t-RVAD is a lifesaving option for patients with severe RHF, but the evidence stems from small non-randomized heterogeneous studies utilizing a variety of devices. Both the etiology of RHF and time of intervention might play a major role in determining the t-RVAD outcome. Standardized endpoints definitions, design and methodology for t-RVAD trials is needed. Furthermore, efforts should continue in improving the technology as well as improving the timely provision of a t-RVAD

    Heart Failure Association-International Cardio-Oncology Society Risk Score Validation in HER2-Positive Breast Cancer

    No full text
    Background: This paper looks to validate the risk score from the Heart Failure Association of the European Society of Cardiology and the International Cardio-Oncology Society (HFA-ICOS) for predicting potential cardiotoxicity from anticancer therapy for patients positive for human epidermal growth factor receptor 2. Methods: A total of 507 patients with at least five years since index diagnosis of breast cancer were retrospectively divided according to the HFA-ICOS risk proforma. According to level of risk, these groups were assessed for rates of cardiotoxicity via mixed-effect Bayesian logistic regression model. Results: A follow-up of five years observed cardiotoxicity of 3.3% (n = 3) in the low-risk, 3.3% (n = 10) in the medium-risk, 4.4% (n = 6) in the high-risk, and 38% (n = 6) in the very-high-risk groups respectively. For cardiac events related to treatment, the risk was significantly higher for the very-high-risk category of HFA-ICOS compared to other categories (Beta = 3.1, 95% CrI: 1.5, 4.8). For overall cardiotoxicity related to treatment, the area under the curve was 0.643 (CI 95%: 0.51, 0.76), with 26.1% (95% CI: 8%, 44%) sensitivity and 97.9% (95% CI: 96%, 99%) specificity. Conclusions: The HFA-ICOS risk score has moderate power in predicting cancer therapy–related cardiotoxicity in HER2-positive breast cancer patients

    Core Lab Adjudication of the ACURATE neo2 Hemodynamic Performance Using Computed-Tomography-Corrected Left Ventricular Outflow Tract Area

    No full text
    (1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Dopplerderived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 62.04 mm2 vs. 405.22 81.32 mm2) (95% Credible interval (CrI) of differences: 55.15, 36.09), which resulted in smaller EOA (2.25 0.59 vs. 2.58 0.63 cm2) (Beta = 0.642 (95%CrI of differences: 0.85, 0.43), and lower SV (73.88 21.41 vs. 84.47 22.66 mL), (Beta = 7.29 (95% CrI: 14.45, 0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies
    corecore