505 research outputs found

    Recommendations for the use of endoscopic lung volume reduction in South Africa: Role in the treatment of emphysema

    Get PDF
    Emphysema is a very common cause of morbidity and mortality in South Africa (SA). Therapeutic options in severe emphysema are limited. Endoscopic lung volume reduction (ELVR) is increasingly being used internationally for the treatment of advanced emphysema in a subset of patients with advanced disease, aiming to obtain the same functional advantages as surgical lung volume reduction while reducing risks and costs. In addition to endobronchial valves, ELVR using endobronchial coils is now available in SA. The high cost of these interventions underscores the need for careful patient selection to best identify those who may or may not benefit from ELVR-related procedures. The Assembly on Interventional Pulmonology of the South African Thoracic Society appointed a committee comprising both local and international experts to extensively review all relevant evidence and provide advice on the use of ELVR in SA based on published evidence, expert opinion and local access to the various devices

    Endoscopic Lung Volume Reduction: An Expert Panel Recommendation

    Get PDF
    Chronic obstructive pulmonary disease (COPD) is a progressive condition comprising a constellation of disorders from chronic bronchitis, airflow obstruction through to emphysema. The global burden of COPD is estimated at more than 6% of the population. The standard of care is based on a combination of smoking cessation, immunization, pharmacological treatments and pulmonary rehabilitation. However, the more advanced stages of COPD are challenging to manage. In this situation, our current standards of care do not adequately control patient symptoms nor halt the progressive decline. For the emphysema phenotype, lung volume reduction surgery has shown a beneficial effect in selected patients but is counterbalanced by the morbidity experienced by some patients. Bronchoscopic volume reduction technologies have been developed to improve the clinical situation of emphysema patients. This expert statement provides broad guidance regarding patient selection and the current position of the available techniques for patients with advanced emphysema

    Influence of airway‐occluding instruments on airway pressure during jet ventilation for rigid bronchoscopy

    Get PDF
    We measured changes in airway pressure (Paw) caused by microsurgical instruments introduced into a rigid bronchoscope during high frequency jet ventilation (HFJV). With approval of the institutional Ethics Committee, 10 adults undergoing elective tracheobronchial endoscopy and endosonography during general anaesthesia were investigated. Inflation of an endosonography probe balloon in the left main stem bronchus caused airway obstruction. Pressure measurements proximal and distal to the obstruction were compared after three degrees of obstruction (0%, 50% and 90%) and with two different driving pressure settings. Airway obstruction increased the mean (sd) peak inspiratory pressure (PIP) from 7.5 (2.6) to 9.5 (3.5) mm Hg for 2 atm (P=0.0008) and from 9.7 (3.7) to 13.0 (5.1) mm Hg for 3 atm (P=0.0001). Airway obstruction did not alter peripheral PIP (7.2 (4.1) to 7.1 (3.7) mm Hg for 2 atm and 8.8 (4.3) to 9.4 (5.2) mm for 3 atm), but resulted in an end‐expiratory pressure (EEP) beyond the narrowing being significantly greater than in the unobstructed airway (2.5 (3.4) to 5.5 (3.7) mm Hg for 2 atm; P=0.0005) and 3.2 (3.6) to 8.0 (4.3) mm for 3 atm; P<0.0001). Severe airway narrowing increases inspiratory pressure proximal and expiratory pressure distal to the obstruction in relation to the applied driving pressure. Since the distal EEP never exceeded PIP, even near‐total airway obstruction should not cause severe lung distension or barotrauma in subjects with normal lungs. Br J Anaesth 2000; 85: 463-

    Endobronchial coils for emphysema:Dual mechanism of action on lobar residual volume reduction

    Get PDF
    BACKGROUND AND OBJECTIVE: The RENEW trial demonstrated that bronchoscopic lung volume reduction using endobronchial coils improves quality of life, pulmonary function and exercise performance. In this post hoc analysis of RENEW, we examine the mechanism of action of endobronchial coils that drives improvement in clinical outcomes. METHODS: A total of 78 patients from the RENEW coil-treated group who were treated in one or both lobes that were deemed as the most destroyed were included in this retrospective analysis. Expiratory and inspiratory HRCT scans were used to assess lobar volume change from baseline to 12 months post coil treatment in treated and untreated lobes. RESULTS: Reduction in lobar RV in treated lobes was significantly associated with favourable clinical improvement. Independent predictor of the change in RV and FEV1 was the change in lobar RV reduction in the treated lobes and for change in 6MWD the absence of cardiac disease and the change in SGRQ, while the independent predictor of change in SGRQ was the change in 6MWD. CONCLUSION: Our results suggest that residual lobar volume reduction in treated lobes measured by QCT is the driving mechanism of action of endobronchial coils leading to positive clinical outcomes. However, the improvement in exercise capacity and quality of life seems to be affected by the presence of cardiac disease

    Smoking-related lung diseases: a clinical perspective

    Full text link

    Successful treatment of a recurrent granulation polyp in the airways with high-dose-rate brachytherapy: a case report

    Get PDF
    Background Benign central airway tumors are very rare diseases. Their unspecific symptoms are responsible for late diagnosis. Endoscopic interventions with different techniques and tools are widely used for their treatment. However, in certain cases interventional endoscopy might be unsuccessful and therefore other methods such as high-dose-rate brachytherapy could be a therapeutic option. Case presentation A 76-year-old white German woman was referred to our clinic for an endoscopic treatment of a recurrent granulation polyp in her left main bronchus. She had dyspnea, coughing, and mucus retention. Three times resections via bronchoscopy were performed within less than a year. After each intervention the polyp regrew inside her left main bronchus causing a repeat of the initial symptoms. She presented to our clinic less than 1 month since the last intervention. Twice we performed a rigid bronchoscopy in total anesthesia where we resected the granulation polyp with a snare wire loop and did an argon plasma coagulation of its base. Due to the recurrent growing of the granuloma, we performed a high-dose-rate brachytherapy in conscious sedation after another interventional bronchoscopy with a resection of the polyp and argon plasma coagulation of the base. Three months after brachytherapy our patient came to our clinic for a follow-up with none of the initial symptoms. Only a small remnant of the polyp without a significant occlusion of her bronchus was visualized by bronchoscopy. Furthermore, 6 months after brachytherapy she was not presenting any of the initial symptoms. Conclusions This case report shows that high-dose-rate brachytherapy is a therapeutic option for the treatment of benign airway stenosis when other interventional treatments are not or are less than successful. However, further investigations are needed to prove the effectiveness and reliability of the method

    Treatment of Advanced Emphysema with Emphysematous Lung Sealant (AeriSeal (R))

    Get PDF
    Background: This report summarizes initial tests of an emphysematous lung synthetic polymer sealant (ELS) designed to reduce lung volume in patients with advanced emphysema. Objectives: The primary study objective was to define a therapeutic strategy to optimize treatment safety and effectiveness. Methods: ELS therapy was administered bronchoscopically to 25 patients with heterogeneous emphysema in an open-label, noncontrolled study at 6 centers in Germany. Treatment was performed initially at 2-4 subsegments. After 12 weeks, patients were eligible for repeat therapy to a total of 6 sites. Safety and efficacy were assessed after 6 months. Responses were evaluated in terms of changes from baseline in lung physiology, functional capacity, and health-related quality of life. Follow-up is available for 21 of 25 patients. Results: Treatment was well tolerated. There were no treatment-related deaths (i.e. within 90 days of treatment), and an acceptable short-and long-term safety profile. Physiological and clinical benefits were observed at 24 weeks. Efficacy responses were better among Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage III patients {[}n = 14; change in residual volume/total lung capacity (Delta RV/TLC) = -7.4 +/- 10.3%; Delta forced expiratory volume in 1 s (Delta FEV(1)) = +15.9 +/- 22.6%; change in forced vital capacity (Delta FVC) = +24.1 +/- 22.7%; change in carbon monoxide lung diffusion capacity (Delta DLCO) = +19.3 +/- 34.8%; change in 6-min walk test (Delta 6MWD) = +28.7 +/- 59.6 m; change in Medical Research Council Dyspnea (Delta MRCD) score = -1.0 +/- 1.04 units; change in St. George's Respiratory Questionnaire (Delta SGRQ) score = -9.9 +/- 15.3 units] than for GOLD stage IV patients (n = 7; Delta RV/TLC = -0.5 +/- 6.4%; Delta FEV 1 = +2.3 +/- 12.3%; Delta FVC = +2.6 +/- 21.1%; Delta DLCO = -2.8 +/- 17.2%; Delta 6MWD = +28.3 +/- 58.4 m; Delta MRCD = 0.3 +/- 0.81 units; Delta SGRQ = -6.7 +/- 7.0 units). Conclusions: ELS therapy shows promise for treating patients with advanced heterogeneous emphysema. Additional studies to assess responses in a larger cohort with a longer follow-up are warranted. Copyright (C) 2011 S. Karger AG, Base

    Motion monitoring during a course of lung radiotherapy with anchored electromagnetic transponders : Quantification of inter- and intrafraction motion and variability of relative transponder positions.

    Get PDF
    Purpose Anchored electromagnetic transponders for tumor motion monitoring during lung radiotherapy were clinically evaluated. First, intrafractional motion patterns were analyzed as well as their interfractional variations. Second, intra- and interfractional changes of the geometric transponder positions were investigated.Materials and methods Intrafractional motion data from 7 patients with an upper or middle lobe tumor and three implanted transponders each was used to calculate breathing amplitudes, overall motion amount and motion midlines in three mutual perpendicular directions and three-dimensionally (3D) for 162 fractions. For 6 patients intra- and interfractional variations in transponder distances and in the size of the triangle defined by the transponder locations over the treatment course were determined.Results Mean 3D values of all fractions were up to 4.0, 4.6 and 3.4 mm per patient for amplitude, overall motion amount and midline deviation, respectively. Intrafractional transponder distances varied with standard deviations up to 3.2 mm, while a maximal triangle shrinkage of 36.5% over 39 days was observed.Conclusions Electromagnetic real-time motion monitoring was feasible for all patients. Detected respiratory motion was on average modest in this small cohort without lower lobe tumors, but changes in motion midline were of the same size as the amplitudes and greater midline motion can be observed in some fractions. Intra- and interfractional variations of the geometric transponder positions can be large, so for reliable motion management correlation between transponder and tumor motion needs to be evaluated per patient
    corecore