31 research outputs found

    Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Get PDF
    Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures

    Magnetic resonance imaging versus echocardiography to ascertain the regression of left ventricular hypertrophy after bioprosthetic aortic valve replacement: Results of the REST study.

    Get PDF
    OBJECTIVES: To compare the decrease in left ventricular mass index (LVMI) by magnetic resonance imaging (MRI) versus transthoracic echocardiography (TTE) after aortic valve replacement (AVR) for severe aortic stenosis with Epic and Epic Supra stented porcine bioprostheses (St Jude Medical, Inc, St Paul, Minn). METHODS: This prospective multicenter study enrolled 149 patients who underwent AVR between January 2006 and February 2008. TTE and cardiac MRI measurements of LVMI were made at baseline and at 6 months of follow-up and were compared. Changes in mean pressure gradients were examined using TTE. RESULTS: TTE measurements of LVMI were 48% to 63% higher than the MRI measurements. A decrease in LVMI from 137 \ub1 32 to 95 \ub1 16 g/m(2) with the Epic and from 139 \ub1 29 to 104 \ub1 28 g/m(2) with the Epic Supra valves (P < .0001 for both comparisons) was measured by TTE. Cardiac MRI revealed decreases in LVMI from 84 \ub1 20 to 64 \ub1 12 g/m(2) and from 86 \ub1 27 to 64 \ub1 17 g/m(2) with the Epic and Epic Supra valves, respectively (P < .0001 for both comparisons). TTE revealed a significant regression of mean pressure gradients from 51.6 \ub1 15.3 to 15.5 \ub1 5.2 mm Hg with the Epic and from 46.7 \ub1 19.4 to 17.9 \ub1 12.8 mm Hg with the Epic supra (P < .0001 for both comparisons). CONCLUSIONS: A significant decrease in LVMI was measured after AVR with all sizes of both bioprosthetic models. Because of the overestimation of the decrease in LVMI by the Devereux formula, as well as the higher accuracy and reproducibility of cardiac MRI measurements, the latter should be preferred to TTE. An ultimate validation of this thesis could only be done comparing each of these modalities with pathologic examination
    corecore