38 research outputs found

    Diagnostic accuracy of the response to the brief tachycardia provoked by standing in children suspected for long QT syndrome

    Get PDF
    BACKGROUND Adult long QT syndrome (LQTS) patients have inadequate corrected QT interval (QTc) shortening and an abnormal T-wave response to the sudden heart rate acceleration provoked by standing. In adults, this knowledge can be used to aid an LQTS diagnosis and, possibly, for risk stratification. However, data on the diagnostic value of the standing test in children are currently limited. OBJECTIVE To determine the potential value of the standing test to aid LQTS diagnostics in children. METHODS In a prospective cohort including children (= 490 ms after standing only slightly increased sensitivity (91%, 95% confidence interval [CI]: 80%-98%) and slightly decreased specificity (58%, 95% CI: 47%-70%). Sensitivity increased slightly more when T-wave abnormalities were present (94%, 95% CI: 82%-99%; specificity 53%, 95% CI: 42%-65%). When a baseline QTc >= 440 ms was accompanied by a QTc >= 490 ms and T-wave abnormalities after standing, sensitivity further increased (96%, 95% CI: 85%-99%) at the expense of a further specificity decrease (41%, 95% CI: 30%-52%). Beat-to-beat analysis showed that 30 seconds after standing, LQTS children had a greater increase in heart rate compared to controls, which was more evidently present in LQTS boys and LQTS type 1 children. CONCLUSION In children, the standing test has limited additive diagnostic value for LQTS over a baseline electrocardiogram, while T-wave abnormalities after standing also have limited additional value. The standing test for LQTS should only be used with caution in children.Developmen

    Complex relationships among personality traits, job characteristics, and work behaviors

    Get PDF
    The aim of the study was to investigate the additive, mediating, and moderating effects of personality traits and job characteristics on work behaviors. Job applicants (N = 161) completed personality questionnaires measuring extraversion, neuroticism, achievement motivation, and experience seeking. One and a half years later, supervisors rated the applicants' job performance, and the job incumbents completed questionnaires about skill variety, autonomy, and feedback, work stress, job satisfaction, work self-efficacy, and propensity to leave. LISREL was used to test 15 hypotheses. Perceived feedback mediated the relationship between achievement motivation and job performance. Extraversion predicted work self-efficacy and job satisfaction. Work stress mediated the relationship between neuroticism and job satisfaction. Job satisfaction and experience seeking were related to propensity to leave. Autonomy, skill variety, and feedback were related to job satisfaction

    Irish cardiac society - Proceedings of annual general meeting held 20th & 21st November 1992 in Dublin Castle

    Get PDF

    Manual vs. automatic assessment of the QT-interval and corrected QT

    Get PDF
    AimsSudden cardiac death (SCD) is challenging to predict. Electrocardiogram (ECG)-derived heart rate-corrected QT-interval (QTc) is used for SCD-risk assessment. QTc is preferably determined manually, but vendor-provided automatic results from ECG recorders are convenient. Agreement between manual and automatic assessments is unclear for populations with aberrant QTc. We aimed to systematically assess pairwise agreement of automatic and manual QT-intervals and QTc.Methods and resultsA multi-centre cohort enriching aberrant QTc comprised ECGs of healthy controls and long-QT syndrome (LQTS) patients. Manual QT-intervals and QTc were determined by the tangent and threshold methods and compared to automatically generated, vendor-provided values. We assessed agreement globally by intra-class correlation coefficients and pairwise by Bland–Altman analyses and 95% limits of agreement (LoA). Further, manual results were compared to a novel automatic QT-interval algorithm. ECGs of 1263 participants (720 LQTS patients; 543 controls) were available [median age 34 (inter-quartile range 35) years, 55% women]. Comparing cohort means, automatic and manual QT-intervals and QTc were similar. However, pairwise Bland–Altman-based agreement was highly discrepant. For QT-interval, LoAs spanned 95 (tangent) and 92 ms (threshold), respectively. For QTc, the spread was 108 and 105 ms, respectively. LQTS patients exhibited more pronounced differences. For automatic QTc results from 440–540 ms (tangent) and 430–530 ms (threshold), misassessment risk was highest. Novel automatic QT-interval algorithms may narrow this range.ConclusionPairwise vendor-provided automatic and manual QT-interval and QTc results can be highly discrepant. Novel automatic algorithms may improve agreement. Within the above ranges, automatic QT-interval and QTc results require manual confirmation, particularly if T-wave morphology is challenging.Developmen

    High-resolution structural-functional substrate-trigger characterization: Future roadmap for catheter ablation of ventricular tachycardia

    No full text
    Introduction Patients with ventricular tachyarrhythmias (VT) are at high risk of sudden cardiac death. When appropriate, catheter ablation is modestly effective, with relatively high VT recurrence and complication rates. Personalized models that incorporate imaging and computational approaches have advanced VT management. However, 3D patient-specific functional electrical information is typically not considered. We hypothesize that incorporating non-invasive 3D electrical and structural characterization in a patient-specific model improves VT-substrate recognition and ablation targeting.Materials and methods In a 53-year-old male with ischemic cardiomyopathy and recurrent monomorphic VT, we built a structural-functional model based on high-resolution 3D late-gadolinium enhancement (LGE) cardiac magnetic resonance imaging (3D-LGE CMR), multi-detector computed tomography (CT), and electrocardiographic imaging (ECGI). Invasive data from high-density contact and pace mapping obtained during endocardial VT-substrate modification were also incorporated. The integrated 3D electro-anatomic model was analyzed off-line.Results Merging the invasive voltage maps and 3D-LGE CMR endocardial geometry led to a mean Euclidean node-to-node distance of 5 & PLUSMN; 2 mm. Inferolateral and apical areas of low bipolar voltage ( 0.4) and with higher transmurality of fibrosis. Areas of functional conduction delay or block (evoked delayed potentials, EDPs) were in close proximity to 3D-LGE CMR-derived heterogeneous tissue corridors. ECGI pinpointed the epicardial VT exit at & SIM;10 mm from the endocardial site of origin, both juxtaposed to the distal ends of two heterogeneous tissue corridors in the inferobasal left ventricle. Radiofrequency ablation at the entrances of these corridors, eliminating all EDPs, and at the VT site of origin rendered the patient non-inducible and arrhythmia-free until the present day (20 months follow-up). Off-line analysis in our model uncovered dynamic electrical instability of the LV inferolateral heterogeneous scar region which set the stage for an evolving VT circuit.Discussion and conclusion We developed a personalized 3D model that integrates high-resolution structural and electrical information and allows the investigation of their dynamic interaction during arrhythmia formation. This model enhances our mechanistic understanding of scar-related VT and provides an advanced, non-invasive roadmap for catheter ablation

    Diagnostic accuracy of the standing test in adults suspected for congenital long-QT syndrome

    Get PDF
    BackgroundAn elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS.Methods and ResultsIn adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T‐wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate–corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47–74) in men and 54% (95% CI, 42–66) in women, with a specificity of 90% (95% CI, 80–96) and 89% (95% CI, 81–95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83–94]) but decreased specificity (49% [95% CI, 41–57]). Sensitivity further increased (PConclusionsDespite earlier retrospective studies, a baseline ECG and the standing test in a prospective evaluation displayed a different diagnostic profile for congenital LQTS but no unequivocal synergism or advantage. This suggests that there is markedly reduced penetrance and incomplete expression in genetically confirmed LQTS with retention of repolarization reserve in response to the brief tachycardia provoked by standing.Developmen
    corecore