    Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study

    Get PDF
    BACKGROUND: This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. METHODS: The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. RESULTS: In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p < 0.001). The trend for better outcomes for the novel technique in terms of stiffness and yield load did not reach statistical significance (p > 0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. CONCLUSIONS: The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone

    RECOVERY OF DAILY ACTIVITY PATTERNS IN PATIENTS AFTER ACL RECONSTRUCTION

    Get PDF
    Injuries of the anterior cruciate ligament are one of the most often occurring injuries during sports activities. For young active patients, surgical treatment with repair, augmentation or replacement of the involved structure(s) is advised. The present study compared the outcome after Ligamys repair and Semitendinosus reconstruction during the first six postoperative weeks with objective measurements of the activity/inactivity behavior in daily life

    Surgeon experience with dynamic intraligamentary stabilization does not influence risk of failure

    Get PDF
    Purpose: Studies on dynamic intraligamentary stabilization (DIS) of acute anterior cruciate ligament (ACL) ruptures reported failure rates similar to those of conventional ACL reconstruction. This study aimed to determine whether surgeon experience with DIS is associated with revision rates or patient-reported outcomes. The hypothesis was that more experienced surgeons achieved better outcomes following DIS due to substantial learning curve. Methods: The authors prospectively enrolled 110 consecutive patients that underwent DIS and evaluated them at a minimum of 2 years. The effects of independent variables (surgeon experience, gender, age, adjuvant procedures, tear location, preinjury Tegner score, time from injury to surgery, and follow-up) on four principal outcomes (revision ACL surgery, any re-operation, IKDC and Lysholm score) were analyzed using univariable and multivariable regressions. Results: From the 110 patients enrolled, 14 patients (13%) were lost to follow-up. Of the remaining 96 patients, 11 underwent revision ACL surgery, leaving 85 patients for clinical assessment at a mean of 2.2 +/- 0.4 years (range 2.0-3.8). Arthroscopic reoperations were performed in 26 (27%) patients, including 11 (11%) revision ACL surgeries. Multivariable regressions revealed: (1) no associations between the reoperation rate and the independent variables, (2) better IKDC scores for 'designer surgeons' (b = 10.7; CI 4.9-16.5; p < 0.001), higher preinjury Tegner scores (b = 2.5, CI 0.8-4.2; p = 0.005), and younger patients (b = 0.3, CI 0.0-0.6; p = 0.039), and (3) better Lysholm scores for 'designer surgeons' (b = 7.8, CI 2.8-12.8; p = 0.005) and preinjury Tegner score (b = 1.9, CI 0.5-3.4; p = 0.010). Conclusion: Surgeon experience with DIS was not associated with rates of revision ACL surgery or general re-operations. Future, larger-scaled studies are needed to confirm these findings. Patients operated by 'designer surgeons' had slightly better IKDC and Lysholm scores, which could be due to better patient selection and/or positively biased attitudes of both surgeons and patients

    Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study

    Full text link
    Background: This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. Methods: The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. Results: In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p  0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. Conclusions: The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone.<br

    Effectiveness of a home-based re-injury prevention program on motor control, return to sport and recurrence rates after anterior cruciate ligament reconstruction: study protocol for a multicenter, single-blind, randomized controlled trial (PReP)

    Get PDF
    Background: Although anterior cruciate ligament (ACL) tear-prevention programs may be effective in the (secondary) prevention of a subsequent ACL injury, little is known, yet, on their effectiveness and feasibility. This study assesses the effects and implementation capacity of a secondary preventive motor-control training (the Stop-X program) after ACL reconstruction. Methods and design: A multicenter, single-blind, randomized controlled, prospective, superiority, two-arm design is adopted. Subsequent patients (18–35 years) with primary arthroscopic unilateral ACL reconstruction with autologous hamstring graft are enrolled. Postoperative guideline rehabilitation plus Classic follow-up treatment and guideline rehabilitation plus the Stop-X intervention will be compared. The onset of the Stop-X program as part of the postoperative follow-up treatment is individualized and function based. The participants must be released for the training components. The endpoint is the unrestricted return to sport (RTS) decision. Before (where applicable) reconstruction and after the clearance for the intervention (aimed at 4–8 months post surgery) until the unrestricted RTS decision (but at least until 12 months post surgery), all outcomes will be assessed once a month. Each participant is consequently measured at least five times to a maximum of 12 times. Twelve, 18 and 24 months after the surgery, follow-up-measurements and recurrence monitoring will follow. The primary outcome assessement (normalized knee-separation distance at the Drop Jump Screening Test (DJST)) is followed by the functional secondary outcomes assessements. The latter consist of quality assessments during simple (combined) balance side, balance front and single-leg hops for distance. All hop/jump tests are self-administered and filmed from the frontal view (3-m distance). All videos are transferred using safe big content transfer and subsequently (and blinded) expertly video-rated. Secondary outcomes are questionnaires on patient-reported knee function, kinesiophobia, RTS after ACL injury and training/therapy volume (frequency – intensity – type and time). All questionnaires are completed online using the participants’ pseudonym only. Group allocation is executed randomly. The training intervention (Stop-X arm) consists of self-administered home-based exercises. The exercises are step-wise graduated and follow wound healing and functional restoration criteria. The training frequency for both arms is scheduled to be three times per week, each time for a 30 min duration. The program follows current (secondary) prevention guidelines. Repeated measurements gain-score analyses using analyses of (co-)variance are performed for all outcomes. Trial registration: German Clinical Trials Register, identification number DRKS00015313. Registered on 1 October 2018

    Minimally Invasive Harvest of a Quadriceps Tendon Graft With or Without a Bone Block

    No full text
    The quadriceps tendon (QT) as a graft source for anterior cruciate ligament (ACL) and posterior cruciate ligament reconstruction has recently achieved increased attention. Although many knee surgeons have been using the QT as a graft for ACL revision surgery, it has never gained universal acceptance for primary ACL reconstruction. The QT is a very versatile graft that can be harvested in different widths, thicknesses, and lengths. Conventionally, the QT graft is harvested by an open technique, requiring a 6 to 8 cm longitudinal incision, which often leads to unpleasant scars. We describe a new, minimally invasive, standardized approach in which the QT graft can be harvested through a 2- to 3-cm skin incision and a new option of using the graft without a bone block

    Minimally Invasive Reconstruction of the Medial Patellofemoral Ligament Using Quadriceps Tendon

    No full text
    Reconstruction of the medial patellofemoral ligament (MPFL) for the treatment of patellar instability has received increased attention over the past few years. Most operative techniques use hamstring grafts fixed with bone tunnels and/or anchors on the patella. Despite good clinical results using these techniques, complications such as implant breakage, patellar fractures through bone tunnels, and loss of knee motion have occurred. We present a minimally invasive technique for MPFL reconstruction using a strip of quadriceps tendon. With the use of specially designed instruments, the graft is harvested through a 3-cm transverse incision at the proximal pole of the patella. The tendon strip is then dissected distally on the patella, left attached, and diverged 90° medially underneath the medial prepatellar tissue. The graft is fixed on the femur in 20° of knee flexion in a bone tunnel with a bioabsorbable interference screw (adults) or a bone anchor (children). We think that this technique presents a valuable alternative to common hamstring techniques for primary MPFL reconstruction in children and adults, as well as for MPFL revision surgery

    Anterior Cruciate Ligament Reconstruction Using a Ribbon-Like Graft With a C-Shaped Tibial Bone Tunnel

    No full text
    According to recent anatomic studies, the anterior cruciate ligament (ACL) appears to be a flat, “ribbon-like” structure, with a thin, oval-shaped insertion on the femur and a C-shaped tibial insertion. According to this anatomy, we describe an ACL-reconstruction technique that aims to approximate this natural anatomy. The basic principle of this technique is not to use conventional round tunnels but create tunnel shapes that resemble more closely the original ACL insertion sites. Using either a rectangular quadriceps tendon graft or a “flat” hamstring graft may not only provide a biomechanical advantage with increased rotational stability but also improve bone–tendon healing due to increased bone–tendon contact and decreased diffusion length. Creating a C-shaped tibial tunnel also avoids laceration of the anterior horn of the lateral meniscus, which is frequently harmed during conventional tibial tunnel drilling