41 research outputs found
O ENSAIO DE PIEZOCONE E DE MINICONE NA INVESTIGAÇÃO DO SUBSOLO: ALGUNS EXEMPLOS DE APLICAÇÃO.
The electrical cone penetration and piezocone testing have become increasingly popular for in situ testing in site investigation and geotechnical design. The advances in electronics and computer engineering created smaller, stronger and cheaper devices that have been incorporated to some investigation tools. It contributed for the piezocone testing to be an unequaled logging tool with respect to the delineation of stratigraphy and the continuous quick estimative of soil mechanical parameters. This paper briefly presents the piezocone and the minecone testing. At the last years the piezocone has been used as a logging tool for geo-environmental site investigation, and the mini-cone gives finer details compared to the standard cone, making it more attractive for transportation infrastructure investigation. Some cases histories, where the piezocone were used to identify zones from the soil mass contaminated by salt, and the mini-cone were used to detect failure surface to assess slope stability of a landfill based on back-analysis technique, are presented and discussed. This paper is finished with some comments about the necessity of additional research to adjust this recent and modern technology for site investigation of Brazilian tropical soils.O ensaio de penetração do cone elétrico e do piezocone pertence a um grupo de ensaios de campo, cuja utilização vem sendo cada vez mais difundida. Tanto o avanço da eletrônica como a rápida evolução da informática têm proporcionado equipamentos mais apropriados, menores, mais robustos e mais econômicos, permitindo a incorporação de diversos sensores a essa ferramenta de investigação. Isto contribuiu para que esse ensaio se consagrasse para a descrição contÃnua do perfil geotécnico, a definição do nÃvel de água e para estimativa de parâmetros mecânicos do solo. Neste artigo faz-se uma breve apresentação do piezocone e do minicone elétrico: o primeiro vem sendo utilizado nos últimos anos, especialmente em geotecnia ambiental, e o segundo, na investigação da infra-estrutura de transportes. Apresentam-se e discutem-se exemplos de emprego do piezocone para identificação de regiões do maciço contaminadas e do minicone para detectar a superfÃcie de ruptura de uma seção de um talude de aterro, para avaliar sua estabilidade através de retroanálises. Concluise o trabalho fazendo-se algumas considerações sobre a utilização dessa tecnologia moderna e recente em solos tropicais que ocorrem no Brasil
Aplicação integrada de métodos geofÃsicos em uma área de disposição de resÃduos sólidos urbanos em Bauru-SP
Experimental study of dynamic parameters of some tropical soils in the state of São Paulo
O módulo cisalhante e a razão de amortecimento interno de alguns solos tropicais do Estado de São Paulo foram estudados, iniciando com um levantamento e uma análise crÃtica de resultados de ensaios dinâmicos já realizados em solos brasileiros. Foram realizados ensaios sÃsmicos \"cross-hole\" e de coluna ressonante em diferentes solos tropicais que ocorrem nas cidades de Bauru, São Carlos e Campinas. Os resultados obtidos por estas técnicas são confrontados e comparados com aqueles estimados por expressões empÃricas disponÃveis. Especialmente para os solos de comportamento laterÃtico, o módulo cisalhante máximo medido foi superior à quele estimado, o mesmo ocorrendo com a degradação do módulo. Estas discrepâncias foram atribuÃdas à s caracterÃsticas genéticas destes solos e a condição não saturada, comum em maciços terrosos de regiões tropicais. Novas expressões são propostas para estimativa dos parâmetros dinâmicos dos solos estudados.The shear modulus and the material damping ratio for some tropical soils in the São Paulo State are studied in the present work research. A literature survey and a critica! analysis of the available results related to dynamic tests for brazilian soils were carried out. A serie of cross hole and resonant column tests were performed for tropical soils ocurring in Bauru, São Carlos and Campinas cities. The results obtained with these techniques are confronted and compared wi th those evaluated from empirical relationships which are documented in the geotechnical li terature. The values of maximum shear modulus and the modulus reduction measured were greater than those estimated empirically, mainly for the soils with lateritic behaviour. These disagreements were attributed to genetic characteristics of these soils and unsatured condition, which is quite common in soil masses of tropical regions. New relationships are proposed to estimate the dynamic parameters of the studied soils
Avaliação comparativa de métodos laboratoriais de medição de resistividade elétrica do solo: Uma abordagem teórica
Site Characterization of a Tropical Soil by In Situ Tests
This paper compiles experimental site characterization of an unsaturated tropical soil profile in an experimental research site in Bauru, São Paulo, Brazil. Several in situ campaigns comprised geophysical borehole tests (cross-hole, down-hole and up-hole together with the SPT), as well as mechanical tests (SPT, CPT and SDMT) have been performed. There is an unsaturated sandy soil at the studied site and, according to the MCT Classification System for tropical soils, the first 13 m depth is a colluvium with lateritic soil behavior (LA’) over the residual soil with non-lateritic behavior (NA’). The ratio between seismic (Go) and mechanical (qn, N60, ED, KD and MDMT) parameters was useful to identify the existence of microstructure and to confirm unusual soil behavior for this tropical soil site. CPT and SDMT were efficient for detailed stratigraphic logging, however, the estimative of geotechnical parameters cannot be solely been done base on just conventional correlations defined for sedimentary soil
Site Characterization of a Tropical Soil by In Situ Tests
This paper compiles experimental site characterization of an unsaturated tropical soil profile in an experimental research site in Bauru, São Paulo, Brazil. Several in situ campaigns comprised geophysical borehole tests (cross-hole, down-hole and up-hole together with the SPT), as well as mechanical tests (SPT, CPT and SDMT) have been performed. There is an unsaturated sandy soil at the studied site and, according to the MCT Classification System for tropical soils, the first 13 m depth is a colluvium with lateritic soil behavior (LA’) over the residual soil with non-lateritic behavior (NA’). The ratio between seismic (Go) and mechanical (qn, N60, ED, KD and MDMT) parameters was useful to identify the existence of microstructure and to confirm unusual soil behavior for this tropical soil site. CPT and SDMT were efficient for detailed stratigraphic logging, however, the estimative of geotechnical parameters cannot be solely been done base on just conventional correlations defined for sedimentary soilEste artÃculo presenta la caracterización geotécnica de un perfil de suelo tropical no saturado de un campo experimental localizado en la ciudad de Bauru, São Paulo, Brasil. Fueron ejecutadas varias campañas in-situ, que incluyen ensayos geofÃsicos (cross-hole, down-hole y up-hole con ensayos SPT) y ensayos mecánicos (SPT, CPT e SDMT). Según el sistema de clasificación MCT, los primeros 13 m del sitio de estudio corresponden a un colúvio de matriz arenosa con comportamiento laterÃtico (LA'), seguido por un suelo residual de comportamiento no laterÃtico (NA'). La relación obtenida entre los parámetros sÃsmicos (Go) y mecánicos (qn, N60, ED, KD e MDMT) permitió identificar la presencia de microestructuras y confirmar el comportamiento especÃfico de este material. Los ensayos de CPT y SDMT fueron eficientes para definir detalladamente el perfil estratigráfico; no obstante, la estimativa de los parámetros geotécnicos no puede ser realizada basada únicamente en correlaciones convencionales definidas para suelos sedimentare
O ENSAIO DE PIEZOCONE E DE MINICONE NA INVESTIGAÇÃO DO SUBSOLO: ALGUNS EXEMPLOS DE APLICAÇÃO.
O ensaio de penetração do cone elétrico e do piezocone pertence a um grupo de ensaios de campo, cuja utilização vem sendo cada vez mais difundida. Tanto o avanço da eletrônica como a rápida evolução da informática têm proporcionado equipamentos mais apropriados, menores, mais robustos e mais econômicos, permitindo a incorporação de diversos sensores a essa ferramenta de investigação. Isto contribuiu para que esse ensaio se consagrasse para a descrição contÃnua do perfil geotécnico, a definição do nÃvel de água e para estimativa de parâmetros mecânicos do solo. Neste artigo faz-se uma breve apresentação do piezocone e do minicone elétrico: o primeiro vem sendo utilizado nos últimos anos, especialmente em geotecnia ambiental, e o segundo, na investigação da infra-estrutura de transportes. Apresentam-se e discutem-se exemplos de emprego do piezocone para identificação de regiões do maciço contaminadas e do minicone para detectar a superfÃcie de ruptura de uma seção de um talude de aterro, para avaliar sua estabilidade através de retroanálises. Concluise o trabalho fazendo-se algumas considerações sobre a utilização dessa tecnologia moderna e recente em solos tropicais que ocorrem no Brasil.The electrical cone penetration and piezocone testing have become increasingly popular for in situ testing in site investigation and geotechnical design. The advances in electronics and computer engineering created smaller, stronger and cheaper devices that have been incorporated to some investigation tools. It contributed for the piezocone testing to be an unequaled logging tool with respect to the delineation of stratigraphy and the continuous quick estimative of soil mechanical parameters. This paper briefly presents the piezocone and the minecone testing. At the last years the piezocone has been used as a logging tool for geo-environmental site investigation, and the mini-cone gives finer details compared to the standard cone, making it more attractive for transportation infrastructure investigation. Some cases histories, where the piezocone were used to identify zones from the soil mass contaminated by salt, and the mini-cone were used to detect failure surface to assess slope stability of a landfill based on back-analysis technique, are presented and discussed. This paper is finished with some comments about the necessity of additional research to adjust this recent and modern technology for site investigation of Brazilian tropical soils