15 research outputs found
Investigating sensitivity improvement methods for quadrupolar nuclei in solid-state nuclear magnetic resonance
The study of quadrupolar nuclei using NMR spectroscopy in the solid state significantly increased in popularity from the end of the 20th century, with the introduction of specific methods to acquire
spectra free from the effects of the quadrupolar interaction, that results in broadened lineshapes
that cannot be completely removed by spinning the sample at the magic angle (MAS), unlike most
of the other interactions present in the solid state. The first technique which allows, without any
specific hardware, the removal of this broadening has been the Multiple-Quantum MQMAS experiment. The method quickly gained a popularity within the NMR community, with numerous successful applications published. However, the multiple-quantum filtration step in this experiment relies on severely limits sensitivity, restricting application to the most sensitive nuclei.
Extending the applicability of MQMAS to less receptive nuclei requires the use of signal improvement techniques. There are multiple examples of such approaches in the literature, but most of these require additional optimisation that may be time-consuming, or simply impossible, on less receptive nuclei. This work introduces a novel signal improvement technique for MQMAS, called FAM-N. Its optimisation is solely based on density matrix simulations using SIMPSON, implying no additional experimental optimisation is required, while improving the signal in MQMAS spectra by equivalent or higher amounts than other common methods. In order to prove the applicability of this method on virtually any system, FAM-N has been investigated by simulation, and tested experimentally using a number of model samples, as well as samples known to be challenging to study by NMR.
This work also explores other aspects of NMR spectroscopy on quadrupolar nuclei. Adiabatic inversion of the satellite populations can be performed to improve the central transition signal in static or MAS spectra. A range of methods has been tested and compared, with particular attention given to hyperbolic secant-shaped pulses, for which its performance have been described. Finally, cross-polarisation from a spin I = 1/2 nucleus to a quadrupolar nucleus has been investigated. After reviewing the theory for the static case, simulations have been performed under MAS in order to identify the conditions for efficient magnetisation transfer, with applications in spectral editing or for the combination with MQMAS
Investigating FAM-N pulses for signal enhancement in MQMAS NMR of quadrupolar nuclei
The authors would like to thank EPSRC (EP/K503162/1) for the award of a studentship to HFC and the ERC (EU FP7 Consolidator Grant 614290 “EXONMR”) for support. SEA would also like to thank the Royal Society and Wolfson Foundation for a merit award. The UK 850 MHz solid-state NMR Facility used in this research was funded by EPSRC and BBSRC (contract reference PR140003), as well as the University of Warwick including via part funding through Birmingham Science City Advanced Materials Projects 1 and 2 supported by Advantage West Midlands (AWM) and the European Regional Development Fund (ERDF). Financial support from the TGIR-RMN-THC Fr3050 CNRS to access the 800 MHz spectrometer (Lille) is gratefully acknowledged.Although a popular choice for obtaining high-resolution solid-state NMR spectra of quadrupolar nuclei, the inherently low sensitivity of the multiple-quantum magic-angle spinning (MQMAS) experiment has limited its application for nuclei with low receptivity or when the available sample volume is limited. A number of methods have been introduced in the literature to attempt to address this problem. Recently, we have introduced an alternative, automated approach, based on numerical simulations, for generating amplitude-modulated pulses (termed FAM-N pulses) to enhance the efficiency of the triple- to single-quantum conversion step within MQMAS. This results in efficient pulses that can be used without experimental reoptimisation, ensuring that this method is particularly suitable for challenging nuclei and systems. In this work, we investigate the applicability of FAM-N pulses to a wider variety of systems, and their robustness under more challenging experimental conditions. These include experiments performed under fast MAS, nuclei with higher spin quantum numbers, samples with multiple distinct sites, low-γ nuclei and nuclei subject to large quadrupolar interactions.Publisher PDFPeer reviewe
Sensitivity improvement in 5QMAS NMR Experiments Using FAM-N Pulses
We would like to thank the ERC (EU FP7 Consolidator Grant 614290 “EXONMR”) and EPSRC (award of a studentship to HC through EP/K503162/1). SEA would also like to thank the Royal Society and Wolfson Foundation for a merit award. The UK 850 MHz solid-state NMR Facility used in this research was funded by EPSRC and BBSRC (contract reference PR140003), as well as the University of Warwick including via part funding through Birmingham Science City Advanced Materials Projects 1 and 2 supported by Advantage West Midlands (AWM) and the European Regional Development Fund (ERDF). Collaborative assistance from the 850 MHz Facility Manager (Dinu Iuga, University of Warwick) is acknowledged. The research data supporting this publication can be accessed at DOI: 10.17630/04b0c37f-b803-4dd7-b13a-2004b0b5c482.[49]The multiple-quantum magic-angle spinning (MQMAS) experiment is a popular choice for obtaining high-resolution solid-state NMR spectra of quadrupolar nuclei with half-integer spin quantum number. However, its inherently poor sensitivity limits its application in more challenging systems. In particular, the use of higher-order multiple-quantum coherences, which have the potential to provide higher resolution in the isotropic spectrum, results in a further decrease in sensitivity. Here we extend our recent work, which introduced an automated, high-throughput approach to generate amplitude-modulated composite pulses (termed FAM-N) to improve the efficiency of the conversion of three-quantum coherences, and explore the use of similar pulses in five-quantum MAS experiments. We consider three different approaches, and are able to demonstrate that all three provide good enhancements over single pulse conversion in all but the most extreme cases, and work well at a range of spinning rates. We show that FAM-N pulses are robust to variation in the quadrupolar coupling and rf nutation rate, demonstrating their applicability in multisite systems and systems where direct experimental optimisation of complex composite pulses is not feasible. This work will ease the implementation of higher-order MQMAS experiments and enable their application to materials and systems that were previously deemed to difficult to study.Publisher PDFPeer reviewe
Investigating FAM-N pulses for signal enhancement in MQMAS NMR of quadrupolar nuclei
Although a popular choice for obtaining high-resolution solid-state NMR spectra of quadrupolar nuclei, the inherently low sensitivity of the multiple-quantum magic-angle spinning (MQMAS) experiment has limited its application for nuclei with low receptivity or when the available sample volume is limited. A number of methods have been introduced in the literature to attempt to address this problem. Recently, we have introduced an alternative, automated approach, based on numerical simulations, for generating amplitude-modulated pulses (termed FAM-N pulses) to enhance the efficiency of the triple- to single-quantum conversion step within MQMAS. This results in efficient pulses that can be used without experimental reoptimisation, ensuring that this method is particularly suitable for challenging nuclei and systems. In this work, we investigate the applicability of FAM-N pulses to a wider variety of systems, and their robustness under more challenging experimental conditions. These include experiments performed under fast MAS, nuclei with higher spin quantum numbers, samples with multiple distinct sites, low-Îł nuclei and nuclei subject to large quadrupolar interactions
Efficient amplitude-modulated pulses for triple- to single-quantum coherence conversion in MQMAS NMR
The conversion between multiple- and single-quantum coherences is integral to many nuclear magnetic resonance (NMR) experiments of quadrupolar nuclei. This conversion is relatively inefficient when effected by a single pulse, and many composite pulse schemes have been developed to improve this efficiency. To provide the maximum improvement, such schemes typically require time-consuming experimental optimization. Here, we demonstrate an approach for generating amplitude-modulated pulses to enhance the efficiency of the triple- to single-quantum conversion. The optimization is performed using the SIMPSON and MATLAB packages and results in efficient pulses that can be used without experimental reoptimisation. Most significant signal enhancements are obtained when good estimates of the inherent radio-frequency nutation rate and the magnitude of the quadrupolar coupling are used as input to the optimization, but the pulses appear robust to reasonable variations in either parameter, producing significant enhancements compared to a single-pulse conversion, and also comparable or improved efficiency over other commonly used approaches. In all cases, the ease of implementation of our method is advantageous, particularly for cases with low sensitivity, where the improvement is most needed (e.g., low gyromagnetic ratio or high quadrupolar coupling). Our approach offers the potential to routinely improve the sensitivity of high-resolution NMR spectra of nuclei and systems that would, perhaps, otherwise be deemed "too challenging"
Sensitivity improvement in 5QMAS NMR Experiments Using FAM-N Pulses
The multiple-quantum magic-angle spinning (MQMAS) experiment is a popular choice for obtaining high-resolution solid-state NMR spectra of quadrupolar nuclei with half-integer spin quantum number. However, its inherently poor sensitivity limits its application in more challenging systems. In particular, the use of higher-order multiple-quantum coherences, which have the potential to provide higher resolution in the isotropic spectrum, results in a further decrease in sensitivity. Here we extend our recent work, which introduced an automated, high-throughput approach to generate amplitude-modulated composite pulses (termed FAM-N) to improve the efficiency of the conversion of three-quantum coherences, and explore the use of similar pulses in five-quantum MAS experiments. We consider three different approaches, and are able to demonstrate that all three provide good enhancements over single pulse conversion in all but the most extreme cases, and work well at a range of spinning rates. We show that FAM-N pulses are robust to variation in the quadrupolar coupling and rf nutation rate, demonstrating their applicability in multisite systems and systems where direct experimental optimisation of complex composite pulses is not feasible. This work will ease the implementation of higher-order MQMAS experiments and enable their application to materials and systems that were previously deemed to difficult to study
Nuclear overhauser spectroscopy of chiral CHD methylene groups
Nuclear magnetic resonance spectroscopy (NMR) can provide a great deal of information about structure and dynamics of biomolecules. The quality of an NMR structure strongly depends on the number of experimental observables and on their accurate conversion into geometric restraints. When distance restraints are derived from nuclear Overhauser effect spectroscopy (NOESY), stereo-specific assignments of prochiral atoms can contribute significantly to the accuracy of NMR structures of proteins and nucleic acids. Here we introduce a series of NOESY-based pulse sequences that can assist in the assignment of chiral CHD methylene protons in random fractionally deuterated proteins. Partial deuteration suppresses spin-diffusion between the two protons of CH2 groups that normally impedes the distinction of cross-relaxation networks for these two protons in NOESY spectra. Three and four-dimensional spectra allow one to distinguish cross-relaxation pathways involving either of the two methylene protons so that one can obtain stereospecific assignments. In addition, the analysis provides a large number of stereospecific distance restraints. Non-uniform sampling was used to ensure optimal signal resolution in 4D spectra and reduce ambiguities of the assignments. Automatic assignment procedures were modified for efficient and accurate stereospecific assignments during automated structure calculations based on 3D spectra. The protocol was applied to calcium-loaded calbindin D-9k. A large number of stereospecific assignments lead to a significant improvement of the accuracy of the structure
Trace Level Detection and Quantification of Crystalline Silica in an Amorphous Silica Matrix with Natural Abundance Si-29 NMR
A protocol for the detection of trace amounts of quartz in amorphous silica gels by NMR spectroscopy was developed and tested on commercially available samples. Using natural abundance 29Si MAS NMR spectroscopy with CPMG acquisition and standard addition of crystalline quartz, quantitative detection of quartz concentrations down to 0.1% wt. was achieved. CPMG permitted to suppress the amorphous silica-derived signal, benefitting from the extremely long T2 relaxation time of quartz in 29Si and hence dramatically increasing the sensitivity. Dedicated post-processing exploiting the known CPMG spikelet frequencies allowed to probe the near-absence of quartz in commercial, 100% silica samples, enabling assessment of conformity of unknown samples to EU legislation (REACH).status: publishe