272 research outputs found

    Injection locking of a low cost high power laser diode at 461 nm

    Get PDF
    Stable laser sources at 461 nm are important for optical cooling of strontium atoms. In most existing experiments this wavelength is obtained by frequency doubling infrared lasers, since blue laser diodes either have low power or large emission bandwidths. Here, we show that injecting less than 10 mW of monomode laser radiation into a blue multimode 500 mW high power laser diode is capable of slaving at least 50% of the power to the desired frequency. We verify the emission bandwidth reduction by saturation spectroscopy on a strontium gas cell and by direct beating of the slave with the master laser. We also demonstrate that the laser can efficiently be used within the Zeeman slower for optical cooling of a strontium atomic beam.Comment: 2nd corrected version (minor revisions); Manuscript accepted for publication in Review of Scientific Instruments; 5 pages, 6 figure

    One dimensional magneto-optical compression of a cold CaF molecular beam

    Get PDF
    We demonstrate with a RF-MOT the one dimensional, transverse magneto-optical compression of a cold beam of calcium monofluoride (CaF). By continually alternating the magnetic field direction and laser polarizations of the magneto-optical trap, a photon scattering rate of 2π×2\pi \times0.4 MHz is achieved. A 3D model for this RF-MOT, validated by agreement with data, predicts a 3D RF-MOT capture velocity for CaF of 5 m/s

    Autonomous systems in anesthesia : where do we stand in 2020? A narrative review

    Get PDF
    As most of us are aware, almost every facet of our society is becoming, for better or worse, progressively more technology-dependent. Technological advancement has made autonomous systems, also known as robots, an integral part of our life in several fields, including medicine. The application of robots in anesthesia could be classified into 3 types of robots. The first ones are pharmacological robots. These robots are based on closed-loop systems that allow better-individualized anesthetic drug titration for optimal homeostasis during general anesthesia and sedation. Recent evidence also demonstrates that autonomous systems could control hemodynamic parameters proficiently outperforming manual control in the operating room. The second type of robot is mechanical. They enable automated motorized reproduction of tasks requiring high manual dexterity level. Such robots have been advocated to be more accurate than humans and, thus, could be safer for the patient. The third type is a cognitive robot also known as decision support system. This type of robot is able to recognize crucial clinical situation that requires human intervention. When these events occur, the system notifies the attending clinician, describes relevant related clinical observations, proposes pertinent therapeutic options and, when allowed by the attending clinician, may even administer treatment. It seems that cognitive robots could increase patients' safety. Robots in anesthesia offer not only the possibility to free the attending clinicians from repetitive tasks but can also reduce mental workload allowing them to focus on tasks that require human intelligence such as analytical and clinical approach, lifesaving decision-making capacity, and interpersonal interaction. Nevertheless, further studies have yet to be done to test the combination of these 3 types of robots to maintain simultaneously the homeostasis of multiple biological variables and to test the safety of such combination on a large-scale population

    Laser slowing of CaF molecules to near the capture velocity of a molecular MOT

    Get PDF
    Laser slowing of CaF molecules down to the capture velocity of a magneto-optical trap (MOT) for molecules is achieved. Starting from a two-stage buffer gas beam source, we apply frequency-broadened "white-light" slowing and observe approximately 6x10^4 CaF molecules with velocities near 10\,m/s. CaF is a candidate for collisional studies in the mK regime. This work represents a significant step towards magneto-optical trapping of CaF
    • …
    corecore