16 research outputs found

    Galantamine improves olfactory learning in the Ts65Dn mouse model of Down syndrome

    Get PDF
    Down syndrome (DS) is the most common form of congenital intellectual disability. Although DS involves multiple disturbances in various tissues, there is little doubt that in terms of quality of life cognitive impairment is the most serious facet and there is no effective treatment for this aspect of the syndrome. The Ts65Dn mouse model of DS recapitulates multiple aspects of DS including cognitive impairment. Here the Ts65Dn mouse model of DS was evaluated in an associative learning paradigm based on olfactory cues. In contrast to disomic controls, trisomic mice exhibited significant deficits in olfactory learning. Treatment of trisomic mice with the acetylcholinesterase inhibitor galantamine resulted in a significant improvement in olfactory learning. Collectively, our study indicates that olfactory learning can be a sensitive tool for evaluating deficits in associative learning in mouse models of DS and that galantamine has therapeutic potential for improving cognitive abilities

    A Monte Carlo study of the energy dependence of Al<sub>2</sub>O<sub>3</sub>: C crystals for real-time in vivo dosimetry in mammography

    No full text
    In a previous experimental study, a novel method for in vivo dosimetry has been investigated, based on radioluminescence (RL) and optically stimulated luminescence (OSL). However, because of (fie large difference in atomic composition between the detector material and the breast tissue, relatively large energy dependence in low-energy X-ray beams can be expected. In the present work, the energy dependence of Al2O3:C crystals was modelled with the Monte Carlo code EGSnre using three types of X-ray spectra. The results obtained (5.6-7.3%) agree with a previously determined experimental result (9%) within the combined standard uncertainty of the two methods. The influence of the size of the crystal on the energy dependence was investigated together with the effect of varying the thickness of the surrounding light-protective material. The results obtained indicate a minor effect owing to the thickness of the light-protective material, and a somewhat larger effect from reducing the diameter of the crystal. The outcome of this study can be used to improve the future design of the RL/OSI. dosimetry system for use in mammography

    In vivo absorbed dose measurements in mammography using a new real-time luminescence technique

    No full text
    A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography

    Language support for changeable large real time systems

    No full text

    Quality assurance and quality control in mammography: a review of available guidance worldwide

    Get PDF
    Objectives - Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Methods - Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Results - Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. Conclusions - The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources
    corecore