61 research outputs found

    Myositis Ossificans Presenting as a Tumor of the Cervical Paraspinal Muscles

    Get PDF
    Abstract : Myositis ossificans (MO) is a benign heterotopic bone formation within muscle or soft tissue that is predominantly initiated by trauma. The diagnostic challenge is to distinguish it from bone and soft tissue malignancies. The most common location of MO is the muscles of the thigh and the upper arm, whereas the neck is only rarely involved. A broad range of theories about the etiology of MO exists in the literature, but minor or major trauma can be found in almost every instance. We present a patient in which additional hybrid imaging with singlephoton emission tomography (SPECT) and computed tomography helped to confirm the diagnosis of MO in the paraspinal cervical muscle

    SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site

    Get PDF
    Purpose: SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. Methods: A consecutive series of knees (n = 66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Results: Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. Conclusions: SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientatio

    SPECT/CT in patients with painful knee arthroplasty—what is the evidence?

    Get PDF
    SPECT/CT is increasingly recognized as a promising imaging modality for the investigation of patients with a painful knee after knee arthroplasty. In this review article, we give an overview of the clinical value and current and future applications of SPECT/CT for patients with knee pain following joint arthroplasty. A detailed evidence-based literature review is performed and presente

    4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty

    Get PDF
    Objective: The purpose was to evaluate the intra- and inter-observer reliability of combined quantitative 3D-volumetric single-photon emission computed tomography (SPECT)/CT analysis including size, intensity and localisation of tracer uptake regions and total knee arthroplasty (TKA) position. Materials and methods: Tc-99m-HDP-SPECT/CT of 100 knees after TKA were prospectively analysed. The anatomical areas represented by a previously validated localisation scheme were 3D-volumetrically analysed. The maximum intensity was recorded for each anatomical area. Ratios between the respective value and the mid-shaft of the femur as the reference were calculated. Femoral and tibial TKA position (varus-valgus, flexion-extension, internal rotation- external rotation) were determined on 3D-CT. Two consultant radiologists/nuclear medicine physicians interpreted the SPECT/CTs twice with a 2-week interval. The inter- and intra-observer reliability was determined (ICCs). Kappa values were calculated for the area with the highest tracer uptake between the observers. Results: The measurements of tracer uptake intensity showed excellent inter- and intra-observer reliabilities for all regions (tibia, femur and patella). Only the tibial shaft area showed ICCs 0.84). Conclusion: This combined 3D-volumetric standardised method of analysing the location, size and the intensity of SPECT/CT tracer uptake regions ("hotspots”) and the determination of the TKA position was highly reliable and represents a novel promising approach to biomechanic

    Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT

    Get PDF
    Purpose: The current study investigates whether patella height and tilt or leg alignment influence the intensity values as well as the distribution pattern of single photon emission computerized tomography/computerized tomography (SPECT/CT) tracer uptake in the patellofemoral joint. Methods: 99mTc-HDP-SPECT/CT and radiographs of consecutive 84 knees were prospectively obtained. Lateral radiographs were analyzed in terms of patellar height, Insall-Salvati index and modified Insall-Salvati index. Skyline views were analyzed for Laurin's lateral patellofemoral angle. On long-leg radiographs, the mechanical leg alignment was classified as varus, valgus or neutral. SPECT/CT was analyzed for each anatomical region using a previously validated SPECT/CT localization and grading algorithm. Mean, standard deviation, minimum and maximum of grading for each area of the localization scheme were recorded. Nonparametric Spearman's correlations were used to correlate patellar height, lateral patellar angle and leg alignment with the tracer uptake intensity. Chi-square statistics were used for categorical data (p<0.05). Results: A patella baja correlated significantly with higher SPECT/CT tracer uptake in all patellar and lateral femoral regions (p<0.001). A higher lateral patellar tilt correlated significantly with higher tracer uptake in the superior lateral femoral parts and the tibial tubercle. In mechanically varus aligned knees, there was significantly higher SPECT/CT tracer uptake on the medial and in valgus knees on the lateral part of the patellofemoral joint (p<0.05). Conclusions: As the intensity and distribution of the SPECT/CT significantly correlated with patella baja and patellar tilt, SPECT/CT might be considered as imaging modality for evaluating patients with patellofemoral disorders and for follow-up of patients after patellofemoral realignment procedures. Level of evidence: Diagnostic study, Level II

    The impact of 18F-FDG PET on the management of patients with suspected large vessel vasculitis

    Get PDF
    Purpose: We aimed to assess the impact of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) on the management of patients with suspected large vessel vasculitis. Methods: An international expert panel determined diagnoses and clinical management in patients with suspected large vessel vasculitis, with and without the results of 18F-FDG PET, respectively. The accuracy of the clinical diagnosis and the resulting clinical management with and without the 18F-FDG PET results were compared using logistic regression models. Results: The analysis included 30 patients referred to a tertiary care centre with large vessel vasculitis and 31 controls. 18F-FDG PET had an overall sensitivity of 73.3% [95% confidence interval (CI) 54.1-87.7%], a specificity of 83.9% (95% CI 66.3-94.5%), a positive predictive value of 81.5% (95% CI 61.9-93.7%) and a negative predictive value of 76.5% (95% CI 58.8-89.3%). The diagnostic accuracy of 18F-FDG PET was higher in patients not receiving immunosuppressive drugs (93.3 vs 64.5%, p = 0.006). Taken in context with other available diagnostic modalities, the addition of 18F-FDG PET increased the clinical diagnostic accuracy from 54.1 to 70.5% (p = 0.04). The addition of 18F-FDG PET increased the number of indicated biopsies from 22 of 61 patients (36.1%) to 25 of 61 patients (41.0%) and changed the treatment recommendation in 8 of 30 patients (26.7%) not receiving immunosuppressive medication and in 7 of 31 patients (22.6%) receiving immunosuppressive medication. Conclusion: 18F-FDG PET is a sensitive and specific imaging tool for large vessel vasculitis, especially when performed in patients not receiving immunosuppressive drugs. It increases the overall diagnostic accuracy and has an impact on the clinical management in a significant proportion of patient

    Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions.</p> <p>Methods</p> <p>We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity.</p> <p>Results</p> <p>Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology.</p> <p>Conclusions</p> <p>Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.</p

    Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).</p> <p>Methods</p> <p>Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p < 0.05) was performed to identify any correlations between component position, tracer uptake and diagnosis.</p> <p>Results</p> <p>SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83%) knees. Progression of patellofemoral OA (n = 11), loosening of the tibial (n = 3) and loosening of the femoral component (n = 2) were identified as the leading causes of pain after TKA.</p> <p>Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049) and in the femur (p = 0.051). Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p < 0.001).</p> <p>Conclusions</p> <p>SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.</p
    • …
    corecore