313 research outputs found

    dc readout experiment at the Caltech 40m prototype interferometer

    Get PDF
    The Laser Interferometer Gravitational Wave Observatory (LIGO) operates a 40m prototype interferometer on the Caltech campus. The primary mission of the prototype is to serve as an experimental testbed for upgrades to the LIGO interferometers and for gaining experience with advanced interferometric techniques, including detuned resonant sideband extraction (i.e. signal recycling) and dc readout (optical homodyne detection). The former technique will be employed in Advanced LIGO, and the latter in both Enhanced and Advanced LIGO. Using dc readout for gravitational wave signal extraction has several technical advantages, including reduced laser and oscillator noise couplings as well as reduced shot noise, when compared to the traditional rf readout technique (optical heterodyne detection) currently in use in large-scale ground-based interferometric gravitational wave detectors. The Caltech 40m laboratory is currently prototyping a dc readout system for a fully suspended interferometric gravitational wave detector. The system includes an optical filter cavity at the interferometer's output port, and the associated controls and optics to ensure that the filter cavity is optimally coupled to the interferometer. We present the results of measurements to characterize noise couplings in rf and dc readout using this system

    Seismic isolation and suspension systems for Advanced LIGO

    Get PDF
    To meet the overall isolation and alignment requirements for the optics in Advanced LIGO, the planned upgrade to LIGO, the US laser interferometric gravitational wave observatory, we are developing three sub-systems: a hydraulic external pre-isolator for low frequency alignment and control, a two-stage active isolation platform designed to give a factor of ~1000 attenuation at 10 Hz, and a multiple pendulum suspension system that provides passive isolation above a few hertz. The hydraulic stage uses laminar-flow quiet hydraulic actuators with millimeter range, and provides isolation and alignment for the optics payload below 10 Hz, including correction for measured Earth tides and the microseism. This stage supports the in-vacuum two-stage active isolation platform, which reduces vibration using force feedback from inertial sensor signals in six degrees of freedom. The platform provides a quiet, controlled structure to mount the suspension system. This latter system has been developed from the triple pendulum suspension used in GEO 600, the German/UK gravitational wave detector. To meet the more stringent noise levels required in Advanced LIGO, the baseline design for the most sensitive optics calls for a quadruple pendulum, whose final stage consists of a 40 kg sapphire mirror suspended on fused silica ribbons to reduce suspension thermal noise

    Measurement of Optical Response of a Detuned Resonant Sideband Extraction Interferometer

    Full text link
    We report on the optical response of a suspended-mass detuned resonant sideband extraction (RSE) interferometer with power recycling. The purpose of the detuned RSE configuration is to manipulate and optimize the optical response of the interferometer to differential displacements (induced by gravitational waves) as a function of frequency, independently of other parameters of the interferometer. The design of our interferometer results in an optical gain with two peaks: an RSE optical resonance at around 4 kHz and a radiation pressure induced optical spring at around 41 Hz. We have developed a reliable procedure for acquiring lock and establishing the desired optical configuration. In this configuration, we have measured the optical response to differential displacement and found good agreement with predictions at both resonances and all other relevant frequencies. These results build confidence in both the theory and practical implementation of the more complex optical configuration being planned for Advanced LIGO.Comment: 6 pages, 4 figures, for submission to Phys Rev Letter

    A Comparison of Temperatures Inside Protective Headgear With Indicators of Physiological Strain and Core Temperatures During Exercise in a Hot Environment

    Get PDF
    Introduction: Non-invasive temperature monitoring with a sensor mounted inside protective headgear such as a football or military helmet or a construction hardhat may be an effective method of detecting temperatures that are indicative of increased risk of heat illness. Hothead Technologies has developed a system for providing temperature information to medical personnel responsible for the health of the individual. Purpose: The purposes of this study were to establish the relationship between in-hardhat temperature (Tih) readings, markers of physiological strain and perceptual responses, and to determine the differences between the in-helmet temperature readings and core temperature (Tc) as measured by rectal (Tre) and esophageal (Tes) probes. Methods: Thirty males (age, 24.57 ± 4.32 years; height 180.51 ±7.06 cm; body mass, 81.06 ±9.35 kg; percent body fat, 13.76 ±5.11; VO2max, 46.84 ± 7.10 mL/Kg/min) completed two experimental trials separated by a minimum of one week: a continuous submaximal exercise (CSE) condition and a series of high intensity 30-second sprints (HIE) with a one-minute rest period between each sprint. Exercise in both conditions was carried out in a 36o C environment with a relative humidity of 40% while wearing a standard construction hardhat with a sensor mounted in the forehead area of the head strap, and continued until one of the following two criteria was met: the subject voluntarily terminated the session, or the subject’s Tc reached 39.5oC. Temperatures, heart rate, cardiorespiratory, and perceptual responses were monitored throughout, and balance error scoring system (BESS) and mental function tests were conducted before and after exercise. A physiological strain index (PSI) was calculated from Tc and HR. Results: CV- Calculated from final temp. Conclusion: The general agreement between the Tih and other temperature measures along with the consistency as indicated by the low coefficient of variation in the recordings of the Tih sensors at the point of termination suggest that this device may have application as a warning system for impending heat-related problems

    Upper Limits on a Stochastic Background of Gravitational Waves

    Get PDF
    The Laser Interferometer Gravitational-Wave Observatory has performed a third science run with much improved sensitivities of all three interferometers. We present an analysis of approximately 200 hours of data acquired during this run, used to search for a stochastic background of gravitational radiation. We place upper bounds on the energy density stored as gravitational radiation for three different spectral power laws. For the flat spectrum, our limit of Ω_0<8.4×10^(-4) in the 69–156 Hz band is ~10^5 times lower than the previous result in this frequency range

    Limits on Gravitational-Wave Emission from Selected Pulsars Using LIGO Data

    Get PDF
    We place direct upper limits on the amplitude of gravitational waves from 28 isolated radio pulsars by a coherent multidetector analysis of the data collected during the second science run of the LIGO interferometric detectors. These are the first direct upper limits for 26 of the 28 pulsars. We use coordinated radio observations for the first time to build radio-guided phase templates for the expected gravitational-wave signals. The unprecedented sensitivity of the detectors allows us to set strain upper limits as low as a few times 10^(-24). These strain limits translate into limits on the equatorial ellipticities of the pulsars, which are smaller than 10^(-5) for the four closest pulsars

    Search for Gravitational-wave Inspiral Signals Associated with Short Gamma-ray Bursts During LIGO's Fifth and Virgo's First Science Run

    Get PDF
    Progenitor scenarios for short gamma-ray bursts (short GRBs) include coalescenses of two neutron stars or a neutron star and black hole, which would necessarily be accompanied by the emission of strong gravitational waves. We present a search for these known gravitational-wave signatures in temporal and directional coincidence with 22 GRBs that had sufficient gravitational-wave data available in multiple instruments during LIGO's fifth science run, S5, and Virgo's first science run, VSR1. We find no statistically significant gravitational-wave candidates within a [ – 5, + 1) s window around the trigger time of any GRB. Using the Wilcoxon-Mann-Whitney U-test, we find no evidence for an excess of weak gravitational-wave signals in our sample of GRBs. We exclude neutron star-black hole progenitors to a median 90% confidence exclusion distance of 6.7 Mpc

    First search for gravitational waves from the youngest known neutron star

    Get PDF
    We present a search for periodic gravitational waves from the neutron star in the supernova remnant Cassiopeia A. The search coherently analyzes data in a 12 day interval taken from the fifth science run of the Laser Interferometer Gravitational-Wave Observatory. It searches gravitational-wave frequencies from 100 to 300 Hz and covers a wide range of first and second frequency derivatives appropriate for the age of the remnant and for different spin-down mechanisms. No gravitational-wave signal was detected. Within the range of search frequencies, we set 95% confidence upper limits of (0.7–1.2) × 10^(−24) on the intrinsic gravitational-wave strain, (0.4–4) × 10^(−4) on the equatorial ellipticity of the neutron star, and 0.005–0.14 on the amplitude of r-mode oscillations of the neutron star. These direct upper limits beat indirect limits derived from energy conservation and enter the range of theoretical predictions involving crystalline exotic matter or runaway r-modes. This paper is also the first gravitational-wave search to present upper limits on the r-mode amplitude
    • …
    corecore