95 research outputs found

    Neuartige Entwicklungen in der Kariesdiagnostik und -therapie

    Get PDF

    Diagnostic validity of early proximal caries detection using near-infrared imaging technology on 3D range data of posterior teeth

    Get PDF
    OBJECTIVES This in vitro study analysed potential of early proximal caries detection using 3D range data of teeth consisting of near-infrared reflection images at 850~nm (NIRR). MATERIALS AND METHODS Two hundred fifty healthy and carious permanent human teeth were arranged pairwise, examined with bitewing radiography (BWR) and NIRR and validated with micro-computed tomography. NIRR findings were evaluated from buccal, lingual and occlusal (trilateral) views according to yes/no decisions about presence of caries. Reliability assessments included kappa statistics and revealed high agreement for both methods. Statistical analysis included cross tabulation and calculation of sensitivity, specificity and AUC. RESULTS Underestimation of caries was 24.8% for NIRR and 26.4% for BWR. Overestimation was 10.4% for occlusal NIRR and 0% for BWR. Trilateral NIRR had overall accuracy of 64.8%, overestimation of 15.6% and underestimation of 19.6%. NIRR and BWR showed high specificity and low sensitivity for proximal caries detection. CONCLUSIONS NIRR achieved diagnostic results comparable to BWR. Trilateral NIRR assessments overestimated presence of proximal caries, revealing stronger sensitivity for initial caries detection than BWR. CLINICAL RELEVANCE NIRR provided valid complement to BWR as diagnostic instrument. Investigation from multiple angles did not substantially improve proximal caries detection with NIRR

    Comparison of novel and established caries diagnostic methods: a clinical study on occlusal surfaces

    Get PDF
    BACKGROUND The purpose of this prospective clinical diagnostic study with validation was to compare the diagnostic accuracy of near-infrared transillumination (NIRT), laser fluorescence measurement (LF), alternating current impedance spectroscopy (ACIS) and their combinations as adjunct methods to visual examination (VE) for occlusal caries detection using a hybrid reference standard. METHODS Ninety-six first and second non-cavitated permanent molars from 76 individuals (mean age 24.2) were investigated using (VE) (ICDAS) and bitewing radiography (BWR), as well as NIRT, LF and ACIS. The findings of BWR and NIRT were evaluated by two examiners while the other examinations were conducted by one calibrated dentist. The hybrid reference standard consisted of non-operative validation based on the results of VE and BWR and operative validation. Statistical analysis included cross-tabulations, calculation of sensitivity, specificity and area under the receiver operating characteristic curve at three diagnostic thresholds: caries in general, enamel caries and dentin caries. RESULTS NIRT, LF and ACIS exhibited high sensitivity for caries in general 1.00 (1.00-1.00), 0.77 (0.65-0.88), 0.75 (0.63-0.87)) and for dentin caries (0.97 (0.91-1.03), 0.76 (0.76-0.90), 0.64 (0.47-0.80). Sensitivity values for enamel caries were weak (0.21, 0.11, 0.37). Specificity values did not fall below 0.65 (NIRT) for all categories and methods, except for NIRT at the caries detection threshold (0.27). A combination of LF and ACIS with VE improved the diagnostic performance at the overall and the enamel caries threshold. The other methods showed fair to excellent discrimination at the overall caries threshold (NIRT 0.64, LF 0.89 and ACIS 0.86) and acceptable discrimination at the dentin caries threshold (NIRT 0.82, LF 0.81 and ACIS 0.79). AUROC for enamel caries exhibited the weakest discrimination. Accuracy was 65.6{\%} for VE, 69.8{\%} for BWR, 50.0{\%} for NIRT, 53.1{\%} for LF and 74.0{\%} for ACIS. Reliability assessment for BWR and NIRT showed at least substantial agreements for all analyses. CONCLUSIONS The methods, NIRT, LF and ACIS, revealed different potential but no impeccable performance for occlusal caries detection. All are suitable instruments to detect hidden carious lesion in dentin. As auxiliaries to VE, LF and ACIS showed an increase in diagnostic performance

    Probing pocket depth reduction after non‐surgical periodontal therapy: Tooth‐related factors

    Get PDF
    Background To investigate tooth-related factors that influence the reduction of probing pocket depths (PPD) after non-surgical periodontal therapy (NST). Methods Seven hundred forty-six patients with a total of 16,825 teeth were included and retrospectively analyzed. PPD reduction after NST was correlated with the tooth-related factors; tooth type, number of roots, furcation involvement, vitality, mobility, and type of restoration; using logistic multilevel regression for statistical analysis. Results NST was able to reduce probing depth overall stratified probing depths (1.20 ± 1.51 mm, p ≀ 0.001). The reduction was significantly higher at teeth with higher probing depths at baseline. At pockets with PPD ≄ 6 mm, PPD remains high after NST. Tooth type, number of roots, furcation involvement, vitality, mobility, and type of restoration are significantly and independently associated with the rate of pocket closure. Conclusions The tooth-related factors: tooth type, number of roots, furcation involvement, vitality, mobility, and type of restoration had a significant and clinically relevant influence on phase I and II therapy. Considering these factors in advance may enhance the prediction of sites not responding adequately and the potential need for additional treatment, such as re-instrumentation or periodontal surgery, to ultimately achieve the therapy end points

    Evaluation of direct restorations using the revised FDI criteria

    Get PDF
    Objectives The purpose of this in vitro reliability study was to determine the intra- and inter-examiner agreement of the revised FDI criteria including the categories "fracture of material and retention" (F1) and "caries at restoration margin" (B1). Materials and methods Forty-nine photographs of direct tooth-coloured posterior (n = 25) and anterior (n = 24) restorations with common deficiencies were included. Ten dental experts repeated the assessment in three blinded rounds. Later, the experts re-evaluated together all photographs and agreed on a reference standard. Statistical analysis included the calculation of Cohen's (C kappa), Fleiss' (F kappa), and weighted Kappa (w kappa), the development of a logistic regression with a backward elimination model and Bland/Altman plots.Results Intra- and inter-examiner reliability exhibited mostly moderate to substantial C kappa, F kappa, and w kappa values for posterior restorations (e.g. Intra: F1 C kappa = 0.57, w kappa = 0.74; B1 C kappa = 0.57, w kappa = 0.73/Inter F1 F kappa = 0.32, w kappa = 0.53; B1 F kappa = 0.41, w kappa = 0.64) and anterior restorations (e.g. Intra F1 C kappa = 0.63, w kappa = 0.76; B1 C kappa = 0.48, w kappa = 0.68/Inter F1 F kappa = 0.42, w kappa = 0.57; B1 F kappa = 0.40, w kappa = 0.51). Logistic regression analyses revealed significant differences between the evaluation rounds, examiners, categories, and tooth type. Both the intra- and inter-examiner reliability increased along with the evaluation rounds. The overall agreement was higher for anterior restorations compared to posterior restorations.Conclusions The overall reliability of the revised FDI criteria set was found to be moderate to substantial

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 60∘60^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law E−γE^{-\gamma} with index Îł=2.70±0.02 (stat)±0.1 (sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25 (stat)−1.2+1.0 (sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    The comorbidity and co-medication profile of patients with progressive supranuclear palsy

    Get PDF
    BackgroundProgressive supranuclear palsy (PSP) is usually diagnosed in elderly. Currently, little is known about comorbidities and the co-medication in these patients.ObjectivesTo explore the pattern of comorbidities and co-medication in PSP patients according to the known different phenotypes and in comparison with patients without neurodegenerative disease.MethodsCross-sectional data of PSP and patients without neurodegenerative diseases (non-ND) were collected from three German multicenter observational studies (DescribePSP, ProPSP and DANCER). The prevalence of comorbidities according to WHO ICD-10 classification and the prevalence of drugs administered according to WHO ATC system were analyzed. Potential drug-drug interactions were evaluated using AiDKlinik (R).ResultsIn total, 335 PSP and 275 non-ND patients were included in this analysis. The prevalence of diseases of the circulatory and the nervous system was higher in PSP at first level of ICD-10. Dorsopathies, diabetes mellitus, other nutritional deficiencies and polyneuropathies were more frequent in PSP at second level of ICD-10. In particular, the summed prevalence of cardiovascular and cerebrovascular diseases was higher in PSP patients. More drugs were administered in the PSP group leading to a greater percentage of patients with polypharmacy. Accordingly, the prevalence of potential drug-drug interactions was higher in PSP patients, especially severe and moderate interactions.ConclusionsPSP patients possess a characteristic profile of comorbidities, particularly diabetes and cardiovascular diseases. The eminent burden of comorbidities and resulting polypharmacy should be carefully considered when treating PSP patients
    • 

    corecore