7 research outputs found

    Effect of facemask oxygenation with and without positive pressure ventilation on gastric volume during anesthesia induction in patients undergoing laparoscopic cholecystectomy or partial hepatectomy: a randomized controlled trial

    No full text
    Abstract Background Studies focusing on the relationship between gastric volume and facemask oxygenation without ventilation during apnea in anesthesia induction are scarce. This study compared the change in gastric volume during apnea in anesthesia induction using facemask ventilation and facemask oxygenation without ventilation in adults undergoing laparoscopic surgery. Methods In this prospective, randomized, double-blinded trial, 70 adults undergoing laparoscopic surgery under general anesthesia were divided into two groups to receive facemask oxygenation with and without ventilation for 60 seconds after loss of consciousness. Before anesthesia induction and after endotracheal intubation, the gastric antral cross-sectional area was measured with ultrasound imaging. Arterial blood gases were tested at baseline (T1), after preoxygenation (T2), after loss of consciousness (T3), and before and after endotracheal intubation (T4 and T5, respectively). Results Sixty patients were included (ventilation n = 30; non ventilation n = 30, 10 patients were excluded). The median [IQR] change of gastric antral cross-sectional area in ventilation group was significantly higher than in non ventilation group (0.83 [0.20 to 1.54] vs. 0.10 [− 0.11 to 0.56] cm2, P = 0.001). At T4 and T5, the PaO2 in ventilation group was significantly higher than in non ventilation group (T4: 391.83 ± 61.53 vs. 336.23 ± 74.99 mmHg, P < 0.01; T5: 364.00 ± 58.65 vs. 297.13 ± 86.95 mmHg, P < 0.01), while the PaCO2 in non ventilation group was significantly higher (T4: 46.57 ± 5.78 vs. 37.27 ± 6.10 mmHg, P < 0.01; T5: 48.77 ± 6.59 vs. 42.63 ± 6.03 mmHg, P < 0.01) and the pH value in non ventilation group was significantly lower (T4: 7.35 ± 0.029 vs 7.42 ± 0.047, P < 0.01; T5: 7.34 ± 0.033 vs 7.39 ± 0.044, P < 0.01). At T4, the HCO3 − in non ventilation group was significantly higher (25.79 ± 2.36 vs. 23.98 ± 2.18 mmol l− 1, P < 0.01). Conclusions During apnoea, the increase in gastric volume was milder in patients undergoing facemask oxygenation without ventilation than with positive pressure ventilation. Trial registration ChiCTR2100054193, 10/12/2021, Title: “Effect of positive pressure and non-positive pressure ventilation on gastric volume during induction of general anesthesia in laparoscopic surgery: a randomized controlled trial”. Website: https://www.chictr.ogr.cn

    The Seventh Visual Object Tracking VOT2019 Challenge Results

    No full text
    The Visual Object Tracking challenge VOT2019 is the seventh annual tracker benchmarking activity organized by the VOT initiative. Results of 81 trackers are presented; many are state-of-the-art trackers published at major computer vision conferences or in journals in the recent years. The evaluation included the standard VOT and other popular methodologies for short-term tracking analysis as well as the standard VOT methodology for long-term tracking analysis. The VOT2019 challenge was composed of five challenges focusing on different tracking domains: (i) VOT-ST2019 challenge focused on short-term tracking in RGB, (ii) VOT-RT2019 challenge focused on "real-time" short-term tracking in RGB, (iii) VOT-LT2019 focused on long-term tracking namely coping with target disappearance and reappearance. Two new challenges have been introduced: (iv) VOT-RGBT2019 challenge focused on short-term tracking in RGB and thermal imagery and (v) VOT-RGBD2019 challenge focused on long-term tracking in RGB and depth imagery. The VOT-ST2019, VOT-RT2019 and VOT-LT2019 datasets were refreshed while new datasets were introduced for VOT-RGBT2019 and VOT-RGBD2019. The VOT toolkit has been updated to support both standard short-term, long-term tracking and tracking with multi-channel imagery. Performance of the tested trackers typically by far exceeds standard baselines. The source code for most of the trackers is publicly available from the VOT page. The dataset, the evaluation kit and the results are publicly available at the challenge website(1).Funding Agencies|Slovenian research agencySlovenian Research Agency - Slovenia [J2-8175, P2-0214, P2-0094]; Czech Science Foundation Project GACR [P103/12/G084]; MURI project - MoD/DstlMURI; EPSRCEngineering &amp; Physical Sciences Research Council (EPSRC) [EP/N019415/1]; WASP; VR (ELLIIT, LAST, and NCNN); SSF (SymbiCloud); AIT Strategic Research Programme; Faculty of Computer Science, University of Ljubljana, Slovenia</p
    corecore