365 research outputs found

    Computationally efficient algorithms for the two-dimensional Kolmogorov-Smirnov test

    Get PDF
    Goodness-of-fit statistics measure the compatibility of random samples against some theoretical or reference probability distribution function. The classical one-dimensional Kolmogorov-Smirnov test is a non-parametric statistic for comparing two empirical distributions which defines the largest absolute difference between the two cumulative distribution functions as a measure of disagreement. Adapting this test to more than one dimension is a challenge because there are 2^d-1 independent ways of ordering a cumulative distribution function in d dimensions. We discuss Peacock's version of the Kolmogorov-Smirnov test for two-dimensional data sets which computes the differences between cumulative distribution functions in 4n^2 quadrants. We also examine Fasano and Franceschini's variation of Peacock's test, Cooke's algorithm for Peacock's test, and ROOT's version of the two-dimensional Kolmogorov-Smirnov test. We establish a lower-bound limit on the work for computing Peacock's test of Omega(n^2.lg(n)), introducing optimal algorithms for both this and Fasano and Franceschini's test, and show that Cooke's algorithm is not a faithful implementation of Peacock's test. We also discuss and evaluate parallel algorithms for Peacock's test

    Study on contraction and relaxation of experimentally denervated and immobilized muscles: Comparison with dystrophic muscles

    Get PDF
    The contraction-relaxation mechanism of experimentally denervated and immobilized muscles of the rabbit is examined. Results are compared with those of human dystrophic muscles, in order to elucidate the role and extent of the neurotrophic factor, and the role played by the intrinsic activity of muscle in connection with pathogenesis and pathophysiology of this disease

    The performance of thin NaI(Tl) scintillator plate for dark matter search

    Full text link
    A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed. The performance of the thin NaI(Tl) plate, energy resolution, single photoelectron energy and position sensitivity were tested. An excellent energy resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy was calculated to be approximately 0.42 0.02keV. Position information in the 5cmx5cm area of the detector was also obtained by analyzing the ratio of the number of photons collected at opposite ends of the detector. The position resolution was obtained to be 1cm (FWHM) in the 5cmx5cm area.Comment: 10 pages. Accepted to Journal of Physical Society of Japa

    Solubility, Light Output and Energy Resolution Studies of Molybdenum-Loaded Liquid Scintillators

    Get PDF
    The search for neutrinoless double-beta decay is an important part of the global neutrino physics program. One double-beta decay isotope currently under investigation is 100Mo. In this article, we discuss the results of a feasibility study investigating the use of molybdenum-loaded liquid scintillator. A large, molybdenum-loaded liquid scintillator detector is one potential design for a low-background, internal-source neutrinoless double-beta decay search with 100Mo. The program outlined in this article included the selection of a solute containing molybdenum, a scintillating solvent and the evaluation of the mixture's performance as a radiation detector.Comment: 8 pages, 3 figure

    Comment on "Evidence for Neutrinoless Double Beta Decay"

    Get PDF
    We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.Comment: A comment written to Modern Physics Letters A. 4 pages, no figures. Updated version, accepted for publicatio

    WIMPs search by means of the highly segmented scintillator

    Full text link
    The highly sensitive method to search for WIMPs dark matter particles is proposed. An array of thin NaI(Tl) plate has the great selectivity for distinguishing the WIMPs events and background ones. The principle of signal selection for WIMPs is described. The high sensitivity for SD (spin-dependent) type WIMPs is expected by applying multi-layer system of NaI(Tl) detector.Comment: 11 pages, added some sentences to make the arguments clea
    • …
    corecore