6,021 research outputs found
Multiplication theory for dynamically biased avalanche photodiodes: new limits for gain bandwidth product
Novel theory is developed for the avalanche multiplication process in avalanche photodiodes (APDs) under time-varying reverse-biasing conditions. Integral equations are derived characterizing the statistics of the multiplication factor and the impulse-response function of APDs, as well as their breakdown probability, all under the assumption that the electric field driving the avalanche process is time varying and spatially nonuniform. Numerical calculations generated by the model predict that by using a bit-synchronous sinusoidal biasing scheme to operate the APD in an optical receiver, the pulse-integrated gain-bandwidth product can be improved by a factor of 5 compared to the same APD operating under the conventional static biasing. The bit-synchronized periodic modulation of the electric field in the multiplication region serves to (1) produce large avalanche multiplication factors with suppressed avalanche durations for photons arriving in the early phase of each optical pulse; and (2) generate low avalanche gains and very short avalanche durations for photons arriving in the latter part of each optical pulse. These two factors can work together to reduce intersymbol interference in optical receivers without sacrificing sensitivity
Rumpel-Leede phenomenon in a hypertensive patient due to mechanical trauma: a case report.
In this report, we present an interesting case of a patient with Rumpel-Leede phenomenon, a rare occurrence that can result in significant delays in medical treatment. This phenomenon is characterized by the presence of a petechial rash that results from acute dermal capillary rupture. In our patient, it occurred secondary to raised pressure in the dermal vessels caused by repeated inflation of a sphygmomanometer cuff. Contributory factors in Rumpel-Leede phenomenon include prevalent conditions such as diabetes mellitus, hypertension, thrombocytopenia, chronic steroid use, antiplatelets, and anticoagulants.A 58-year-old Russian woman with diabetes and hypertension presented to our hospital with a non-ST elevation myocardial infarction, and she subsequently developed a petechial rash on her distal upper limbs. A vasculitic screen was performed, with normal results.Given the timing and distribution of the rash, it was felt that this was an example of Rumpel-Leede phenomenon in a susceptible individual. This is an important diagnosis to be aware of in patients with vascular risk factors presenting for acute medical care who subsequently develop a petechial rash
Connected to Give: Faith Communities
This is the third report in the "Connected to Give" series, and compares the relationship between the charitable giving behavior of American's from a variety of backgrounds, including their key demographics; an examination their motivations for giving; and the types of organizations to which they contribute
New Perspective on Passively Quenched Single Photon Avalanche Diodes: Effect of Feedback on Impact Ionization
Single-photon avalanche diodes (SPADs) are primary devices in photon counting systems used in quantum cryptography, time resolved spectroscopy and photon counting optical communication. SPADs convert each photo-generated electron hole pair to a measurable current via an avalanche of impact ionizations. In this paper, a stochastically self-regulating avalanche model for passively quenched SPADs is presented. The model predicts, in qualitative agreement with experiments, three important phenomena that traditional models are unable to predict. These are: (1) an oscillatory behavior of the persistent avalanche current; (2) an exponential (memoryless) decay of the probability density function of the stochastic quenching time of the persistent avalanche current; and (3) a fast collapse of the avalanche current, under strong feedback conditions, preventing the development of a persistent avalanche current. The model specifically captures the effect of the load’s feedback on the stochastic avalanche multiplication, an effect believed to be key in breaking today’s counting rate barrier in the 1.55–μm detection window
Simultaneous measurement of quality factor and wavelength shift by phase shift microcavity ring down spectroscopy
Optical resonant microcavities with ultra high quality factors are widely
used for biosensing. Until now, the primary method of detection has been based
upon tracking the resonant wavelength shift as a function of biodetection
events. One of the sources of noise in all resonant-wavelength shift
measurements is the noise due to intensity fluctuations of the laser source. An
alternative approach is to track the change in the quality factor of the
optical cavity by using phase shift cavity ring down spectroscopy, a technique
which is insensitive to the intensity fluctuations of the laser source. Here,
using biotinylated microtoroid resonant cavities, we show simultaneous
measurement of the quality factor and the wavelength shift by using phase shift
cavity ring down spectroscopy. These measurements were performed for
disassociation phase of biotin-streptavidin reaction. We found that the
disassociation curves are in good agreement with the previously published
results. Hence, we demonstrate not only the application of phase shift cavity
ring down spectroscopy to microcavities in the liquid phase but also
simultaneous measurement of the quality factor and the wavelength shift for the
microcavity biosensors in the application of kinetics measurements
Artifact Rejection Methodology Enables Continuous, Noninvasive Measurement of Gastric Myoelectric Activity in Ambulatory Subjects.
The increasing prevalence of functional and motility gastrointestinal (GI) disorders is at odds with bottlenecks in their diagnosis, treatment, and follow-up. Lack of noninvasive approaches means that only specialized centers can perform objective assessment procedures. Abnormal GI muscular activity, which is coordinated by electrical slow-waves, may play a key role in symptoms. As such, the electrogastrogram (EGG), a noninvasive means to continuously monitor gastric electrical activity, can be used to inform diagnoses over broader populations. However, it is seldom used due to technical issues: inconsistent results from single-channel measurements and signal artifacts that make interpretation difficult and limit prolonged monitoring. Here, we overcome these limitations with a wearable multi-channel system and artifact removal signal processing methods. Our approach yields an increase of 0.56 in the mean correlation coefficient between EGG and the clinical "gold standard", gastric manometry, across 11 subjects (p < 0.001). We also demonstrate this system's usage for ambulatory monitoring, which reveals myoelectric dynamics in response to meals akin to gastric emptying patterns and circadian-related oscillations. Our approach is noninvasive, easy to administer, and has promise to widen the scope of populations with GI disorders for which clinicians can screen patients, diagnose disorders, and refine treatments objectively
- …
