5 research outputs found

    OPTIMAX 2017 : radiation dose, image quality optimisation,the use of new technology in medical imaging

    Get PDF
    This year OPTIMAX settled in Oslo. After the successof previous years, we are proud to present the fourthEbook. As in previous years, the group was madeup of PhD-, MSc- and BSc students as well astutors from the seven European partner universities.Professional mix was drawn from medical physics/physics and radiography. OPTIMAX 2017 was partlyfunded by the partner universities and partly by theparticipants. Two students from South Africa and twofrom Brazil were invited by Hanze UAS (Groningen)and ESTeSL (Lisbon) summer school includedlectures and group projects in which experimentalresearch was conducted in four teams. Four research projects were performed with a focuson radiation dose optimization and image quality,namely: Possible dose reduction for pediatric patientsfor conventional radiology; Can the tube voltage belowered with the use of direct-conversion flat paneldetector system?; Impact of body size and kV in chestradiography; Quantity assessment on Image quality ofCBCT images of head phantom with implants of metaland ceramic objects.The last day of OPTIMAX 2017there was a poster session and a conference, in whichthe research teams presented their posters and oralpresentations. This book comprises of two sections, the first twochapters concern generic background informationabout international teamwork during the OPTIMAXsummerschool. The next chapters with theory on which the researchprojects were built. The second section containsthe research papers of the four research projects.Two research papers, Can the tube voltage belowered with the use of direct-conversion flat-paneldetector system? And Impact of body size and kV inchest radiography: Experimental receiver operatingcharacteristic analysis using a Multipurpose ChestPhantom “Lungman” have been accepted for the ECRconference, Vienna, 2018 as oral presentations

    Surgical repair of distal biceps tendon ruptures : a biomechanical comparison of two techniques

    Get PDF
    PURPOSE: To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. METHODS: The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. Results : There was no difference in pain experience between both paddles (mean difference NRS: 0.08 +/- 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 +/- 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. CONCLUSIONS: Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views
    corecore