24 research outputs found

    Novel genetic loci underlying human intracranial volume identified through genome-wide association

    Get PDF
    Intracranial volume reflects the maximally attained brain size during development, and remains stable with loss of tissue in late life. It is highly heritable, but the underlying genes remain largely undetermined. In a genome-wide association study of 32,438 adults, we discovered five novel loci for intracranial volume and confirmed two known signals. Four of the loci are also associated with adult human stature, but these remained associated with intracranial volume after adjusting for height. We found a high genetic correlation with child head circumference (ρgenetic=0.748), which indicated a similar genetic background and allowed for the identification of four additional loci through meta-analysis (Ncombined = 37,345). Variants for intracranial volume were also related to childhood and adult cognitive function, Parkinson’s disease, and enriched near genes involved in growth pathways including PI3K–AKT signaling. These findings identify biological underpinnings of intracranial volume and provide genetic support for theories on brain reserve and brain overgrowth

    The James Webb Space Telescope Mission

    Full text link
    Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4m4m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5m6.5m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space Telescope Overview, 29 pages, 4 figure

    The Science Performance of JWST as Characterized in Commissioning

    Full text link
    This paper characterizes the actual science performance of the James Webb Space Telescope (JWST), as determined from the six month commissioning period. We summarize the performance of the spacecraft, telescope, science instruments, and ground system, with an emphasis on differences from pre-launch expectations. Commissioning has made clear that JWST is fully capable of achieving the discoveries for which it was built. Moreover, almost across the board, the science performance of JWST is better than expected; in most cases, JWST will go deeper faster than expected. The telescope and instrument suite have demonstrated the sensitivity, stability, image quality, and spectral range that are necessary to transform our understanding of the cosmos through observations spanning from near-earth asteroids to the most distant galaxies.Comment: 5th version as accepted to PASP; 31 pages, 18 figures; https://iopscience.iop.org/article/10.1088/1538-3873/acb29

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: The SonoInsight study

    No full text
    © RSNA, 2014. Purpose: To determine improvement in breast cancer detection by using supplemental three-dimensional (3D) automated breast (AB) ultrasonography (US) with screening mammography versus screening mammography alone in asymptomatic women with dense breasts. Materials and Methods: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study. The SomoInsight Study was an observational, multicenter study conducted between 2009 and 2011. A total of 15 318 women (mean age, 53.3 years ± 10 [standard deviation]; range, 25-94 years) presenting for screening mammography alone with heterogeneously (50%-75%) or extremely (\u3e75%) dense breasts were included, regardless of further risk characterization, and were followed up for 1 year. Participants underwent screening mammography alone followed by an AB US examination; results were interpreted sequentially. McNemar test was used to assess differences in cancer detection. Results: Breast cancer was diagnosed at screening in 112 women: 82 with screening mammography and an additional 30 with AB US. Addition of AB US to screening mammography yielded an additional 1.9 detected cancers per 1000 women screened (95% confidence interval [CI]: 1.2, 2.7; P , .001). Of cancers detected with screening mammography, 62.2% (51 of 82) were invasive versus 93.3% (28 of 30) of additional cancers detected with AB US (P \u3c .001). Of the 82 cancers detected with either screening mammography alone or the combined read, 17 were detected with screening mammography alone. Of these, 64.7% (11 of 17) were ductal carcinoma in situ versus 6.7% (two of 30) of cancers detected with AB US alone. Sensitivity for the combined read increased by 26.7% (95% CI: 18.3%, 35.1%); the increase in the recall rate per 1000 women screened was 284.9 (95% CI: 278.0, 292.2; P \u3c .001). Conclusion: Addition of AB US to screening mammography in a generalizable cohort of women with dense breasts increased the cancer detection yield of clinically important cancers, but it also increased the number of false-positive results

    Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: The somoinsight study

    No full text
    © RSNA, 2014. Purpose: To determine improvement in breast cancer detection by using supplemental three-dimensional (3D) automated breast (AB) ultrasonography (US) with screening mammography versus screening mammography alone in asymptomatic women with dense breasts. Materials and Methods: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study. The SomoInsight Study was an observational, multicenter study conducted between 2009 and 2011. A total of 15 318 women (mean age, 53.3 years ± 10 [standard deviation]; range, 25-94 years) presenting for screening mammography alone with heterogeneously (50%-75%) or extremely (\u3e75%) dense breasts were included, regardless of further risk characterization, and were followed up for 1 year. Participants underwent screening mammography alone followed by an AB US examination; results were interpreted sequentially. McNemar test was used to assess differences in cancer detection. Results: Breast cancer was diagnosed at screening in 112 women: 82 with screening mammography and an additional 30 with AB US. Addition of AB US to screening mammography yielded an additional 1.9 detected cancers per 1000 women screened (95% confidence interval [CI]: 1.2, 2.7; P , .001). Of cancers detected with screening mammography, 62.2% (51 of 82) were invasive versus 93.3% (28 of 30) of additional cancers detected with AB US (P \u3c .001). Of the 82 cancers detected with either screening mammography alone or the combined read, 17 were detected with screening mammography alone. Of these, 64.7% (11 of 17) were ductal carcinoma in situ versus 6.7% (two of 30) of cancers detected with AB US alone. Sensitivity for the combined read increased by 26.7% (95% CI: 18.3%, 35.1%); the increase in the recall rate per 1000 women screened was 284.9 (95% CI: 278.0, 292.2; P \u3c .001). Conclusion: Addition of AB US to screening mammography in a generalizable cohort of women with dense breasts increased the cancer detection yield of clinically important cancers, but it also increased the number of false-positive results
    corecore