6 research outputs found

    Intrathecal immunoglobulin A and G antibodies to synapsin in a patient with limbic encephalitis

    Get PDF
    To report on the identification of intrathecally synthesized immunoglobulin A (IgA) and immunoglobulin G (IgG) antibodies to synapsin, a synaptic vesicle-associated protein, in a patient with limbic encephalitis

    Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT : 5D-PET

    Get PDF
    BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B) (15)O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated (15)O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. RESULTS: Using V B images, high correlations between PET and MRI ESV (r = 0.89, p < 0.001), EDV (r = 0.85, p < 0.001), SV (r = 0.74, p = 0.006) and LVEF (r = 0.72, p = 0.008) were found for the volume-based method. Correlations for FP images were slightly, but not significantly, lower than those for V B images when compared to MRI. Surface- and count-based methods showed no significant difference compared with the volume-based correlations with MRI. The volume-based method showed the best agreement with MRI with no significant difference on average for EDV and LVEF but with an overestimation of values for ESV (14%, p = 0.005) and SV (18%, p = 0.004) when using V B images. Using FP images, none of the parameters showed a significant difference from MRI. Inter-operator repeatability was excellent for all parameters (ICC > 0.86, p < 0.001). CONCLUSION: Calculation of LV volumes and LVEF from dynamic (15)O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting

    Quantitation of mitral regurgitation using positron emission tomography

    No full text
    Background: Cardiac positron emission tomography (PET) offers non-invasive assessment of perfusion and left ventricular (LV) function from a single dynamic scan. However, no prior assessment of mitral regurgitation severity by PET has been presented. Application of indicator dilution techniques and gated image analyses to PET data enables calculation of forward stroke volume and total LV stroke volume. We aimed to evaluate a combination of these methods for measurement of regurgitant volume (RegVol) and fraction (RegF) using dynamic 15O-water and 11C-acetate PET in comparison to cardiovascular magnetic resonance (CMR). Results: Twenty-one patients with severe primary mitral valve regurgitation underwent same-day dynamic PET examinations (O-15-water and C-11-acetate) and CMR. PET data were reconstructed into dynamic series with short time frames during the first pass, gated O-15-water blood pool images, and gated C-11-acetate myocardial uptake images. PET-based RegVol and RegF correlated strongly with CMR (RegVol: O-15-water r = 0.94, C-11-acetate r = 0.91 and RegF: O-15-water r = 0.88, C-11-acetate r = 0.84, p < 0.001). A systematic underestimation (bias) was found for PET (RegVol: O-15-water - 11 +/- 13 mL, p = 0.002, C-11-acetate - 28 +/- 16 mL, p < 0.001 and RegF: O-15-water - 4 +/- 6%, p = 0.01, C-11-acetate - 10 +/- 7%, p < 0.001). PET measurements in patients were compared to healthy volunteers (n = 18). Mean RegVol and RegF was significantly lower in healthy volunteers compared to patients for both tracers. The accuracy of diagnosing moderately elevated regurgitant volume (> 30mL) was 95% for O-15-water and 92% for C-11-acetate. Conclusions: LV regurgitation severity quantified using cardiac PET correlated with CMR and showed high accuracy for discriminating patients from healthy volunteers

    Automatic extraction of forward stroke volume using dynamic PET/CT : a dual-tracer and dual-scanner validation in patients with heart valve disease.

    Get PDF
    BACKGROUND: The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. METHODS: 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). RESULTS: FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14). CONCLUSIONS: FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation

    Cardiovascular Effects of Treatment With the Ketone Body 3-Hydroxybutyrate in Chronic Heart Failure Patients

    No full text
    BACKGROUND: Myocardial utilization of 3-hydroxybutyrate (3-OHB) is increased in patients with heart failure and reduced ejection fraction (HFrEF). However, the cardiovascular effects of increased circulating plasma-3-OHB levels in these patients are unknown. Consequently, the authors' aim was to modulate circulating 3-OHB levels in HFrEF patients and evaluate: (1) changes in cardiac output (CO); (2) a potential doseresponse relationship between 3-OHB levels and CO; (3) the impact on myocardial external energy efficiency (MEE) and oxygen consumption (MVO 2); and (4) whether the cardiovascular response differed between HFrEF patients and age-matched volunteers. METHODS: Study 1: 16 chronic HFrEF patients (left ventricular ejection fraction: 37 +/- 3%) were randomized in a crossover design to 3-hour of 3-OHB or placebo infusion. Patients were monitored invasively with a Swan-Ganz catheter and with echocardiography. Study 2: In a doseresponse study, 8 HFrEF patients were examined at increasing 3-OHB infusion rates. Study 3 to 4: 10 HFrEF patients and 10 age-matched volunteers were randomized in a crossover design to 3-hour 3-OHB or placebo infusion. MEE and MVO 2 were evaluated using 11C-acetate positron emission tomography. RESULTS: 3-OHB infusion increased circulating levels of plasma 3-OHB from 0.4 +/- 0.3 to 3.3 +/- 0.4 mM (P< 0.001). CO rose by 2.0 +/- 0.2 L/min (P< 0.001) because of an increase in stroke volume of 20 +/- 2 mL (P< 0.001) and heart rate of 7 +/- 2 beats per minute (bpm) (P< 0.001). Left ventricular ejection fraction increased 8 +/- 1% (P< 0.001) numerically. There was a dose-response relationship with a significant CO increase of 0.3 L/min already at plasma-3-OHB levels of 0.7 mM (P< 0.001). 3-OHB increased MVO 2 without altering MEE. The response to 3-OHB infusion in terms of MEE and CO did not differ between HFrEF patents and age-matched volunteers. CONCLUSIONS: 3-OHB has beneficial hemodynamic effects in HFrEF patients without impairing MEE. These beneficial effects are detectable in the physiological concentration range of circulating 3-OHB levels. The hemodynamic effects of 3-OHB were observed in both HFrEF patients and age-matched volunteers. 3-OHB may potentially constitute a novel treatment principle in HFrEF patients
    corecore