735 research outputs found
First Observation of 15Be
The neutron-unbound nucleus 15Be was observed for the first time. It was populated using neutron transfer from a deuterated polyethylene target with a 59 MeV/u 14Be beam. Neutrons were measured in coincidence with outgoing 14Be particles and the reconstructed decay energy spectrum exhibits a resonance at 1.8(1) MeV. This corresponds to 15Be being unbound by 0.45 MeV more then 16Be thus significantly hindering the sequential two-neutron decay of 16Be to 14Be through this state
Further Insights into the Reaction Be14(CH2,X)10He
A previously published measurement of the reaction of a 59 MeV/nucleon 14Be beam on a deuterated polyethylene target was further analyzed to search for 12He as well as initial state effects in the population of the 10He ground state. No evidence for either was found. A lower limit of about 1 MeV was determined for a possible resonance in 12He. In addition, the three-body decay energy spectrum of 10He could not be described by a reaction mechanism calculation based on the halo structure of the initial 14Be assuming a direct α-particle removal reaction
Structure and Decay Correlations of Two-Neutron Systems Beyond the Dripline
The two-neutron unbound systems of 16Be, 13Li, 10He, and 26O have been measured using the Modular Neutron Array (MoNA) and 4 Tm Sweeper magnet setup. The correlations of the 3-body decay for the 16Be and 13Li were extracted and demonstrated a strong correlated enhancement between the two neutrons. The measurement of the 10He ground state resonance from a 14Be(−2p2n) reaction provided insight into previous predictions that wavefunction of the entrance channel, projectile, can influence the observed decay energy spectrum for the unbound system. Lastly, the decay-in-target (DiT) technique was utilized to extract the lifetime of the 26O ground state. The measured lifetime of 4.5+1.1 −1.5 (stat.)±3(sys.) ps provides the first indication of two-neutron radioactivity
First Observation of Be-15
The neutron-unbound nucleus Be-15 was observed for the first time. It was populated using neutron transfer from a deuterated polyethylene target with a 59 MeV/u Be-14 beam. Neutrons were measured in coincidence with outgoing Be-14 particles and the reconstructed decay energy spectrum exhibits a resonance at 1.8(1) MeV. This corresponds to Be-15 being unbound by 0.45 MeV more then Be-16 thus significantly hindering the sequential two-neutron decay of Be-16 to Be-14 through this state
Стратегия развития компании на рынке медицинских услуг (на примере ООО «Медицинский Центр «Эверест»)
Объектом исследования в рамках выпускной квалификационной работы является разработка стратегии развития компании и рекомендаций по внедрению организационных инноваций с учетом потребностей клиентов. Предметом – план разработки стратегии развития данного предприятия.
Цель работы: Разработка стратегии развития предприятия с учетом потребностей клиентов.
Актуальность работы заключается в том, что грамотная стратегия развития медицинского предприятия является одной из важнейших областей ведения бизнеса в медицинской сфере. Развитие медицинского обслуживания поможет избавить людей от проблемы многочисленных затрат на лечение в зарубежных клиниках.The subject of the study as part of the final qualification work is the development of company development strategies and recommendations for implementing organizational innovations tailored to the needs of clients. The subject is the plan for developing strategies for the development of this enterprise. The purpose of the work: Developing strategies for the development of enterprises taking into account the needs of clients. The actuality of the work lies in the fact that a competent strategy for the development of a medical enterprise is one of the most important areas of business in the medical field. The development of medical services helps to save people from problems
Ultra-High Energy Cosmic Ray production in the polar cap regions of black hole magnetospheres
We develop a model of ultra-high energy cosmic ray (UHECR) production via
acceleration in a rotation-induced electric field in vacuum gaps in the
magnetospheres of supermassive black holes (BH). We show that if the poloidal
magnetic field near the BH horizon is misaligned with the BH rotation axis,
charged particles, which initially spiral into the BH hole along the equatorial
plane, penetrate into the regions above the BH "polar caps" and are ejected
with high energies to infinity. We show that in such a model acceleration of
protons near a BH of typical mass 3e8 solar masses is possible only if the
magnetic field is almost aligned with the BH rotation axis. We find that the
power of anisotropic electromagnetic emission from an UHECR source near a
supermassive BH should be at least 10-100 times larger then UHECR power of the
source. This implies that if the number of UHECR sources within the 100 Mpc
sphere is ~100, the power of electromagnetic emission which accompanies proton
acceleration in each source, erg/s, is comparable to the typical
luminosities of active galactic nuclei (AGN) in the local Universe. We also
explore the acceleration of heavy nuclei, for which the constraints on the
electromagnetic luminosity and on the alignment of magnetic field in the gap
are relaxed
Unresolved Question of the 10He Ground State Resonance
The group state of 10He was populated using a 2p2n-removal from a 59 MeV/u 14Be beam. The decay energy of the three body system, 8He + n + n, was measured and a resonance was observed at E = 1.60(25) MeV with a 1.8(4) MeV width. This result is in agreement with previous invariant mass spectroscopy measurements, using the 11Li(-p) reaction, but is consistent with recent transfer reaction results. The proposed explanation that the difference, about 500 keV, is due to the effect of the extended halo nature of 11Li in the one-proton knockout reaction is no longer valid as the present work demonstrates that the discrepancy between the transfer reaction is no longer valid as the present work demonstrates that the discrepancy between the transfer reaction results persists despite using a very different reaction mechanism, 14Be(-2p2n)
A comparative study of Tam3 and Ac transposition in transgenic tobacco and petunia plants
Transposition of the Anthirrinum majus Tam3 element and the Zea mays Ac element has been monitored in petunia and tobacco plants. Plant vectors were constructed with the transposable elements cloned into the leader sequence of a marker gene. Agrobacterium tumefaciens-mediated leaf disc transformation was used to introduce the transposable element constructs into plant cells. In transgenic plants, excision of the transposable element restores gene expression and results in a clearly distinguishable phenotype. Based on restored expression of the hygromycin phosphotransferase II (HPTII) gene, we established that Tam3 excises in 30% of the transformed petunia plants and in 60% of the transformed tobacco plants. Ac excises from the HPTII gene with comparable frequencies (30%) in both plant species. When the β-glucuronidase (GUS) gene was used to detect transposition of Tam3, a significantly lower excision frequency (13%) was found in both plant species. It could be shown that deletion of parts of the transposable elements Tam3 and Ac, removing either one of the terminal inverted repeats (TIR) or part of the presumptive transposase coding region, abolished the excision from the marker genes. This demonstrates that excision of the transposable element Tam3 in heterologous plant species, as documented for the autonomous element Ac, also depends on both properties. Southern blot hybridization shows the expected excision pattern and the reintegration of Tam3 and Ac elements into the genome of tobacco plants.
Vertical-external-cavity surface-emitting lasers and quantum dot lasers
The use of cavity to manipulate photon emission of quantum dots (QDs) has
been opening unprecedented opportunities for realizing quantum functional
nanophotonic devices and also quantum information devices. In particular, in
the field of semiconductor lasers, QDs were introduced as a superior
alternative to quantum wells to suppress the temperature dependence of the
threshold current in vertical-external-cavity surface-emitting lasers
(VECSELs). In this work, a review of properties and development of
semiconductor VECSEL devices and QD laser devices is given. Based on the
features of VECSEL devices, the main emphasis is put on the recent development
of technological approach on semiconductor QD VECSELs. Then, from the viewpoint
of both single QD nanolaser and cavity quantum electrodynamics (QED), a
single-QD-cavity system resulting from the strong coupling of QD cavity is
presented. A difference of this review from the other existing works on
semiconductor VECSEL devices is that we will cover both the fundamental aspects
and technological approaches of QD VECSEL devices. And lastly, the presented
review here has provided a deep insight into useful guideline for the
development of QD VECSEL technology and future quantum functional nanophotonic
devices and monolithic photonic integrated circuits (MPhICs).Comment: 21 pages, 4 figures. arXiv admin note: text overlap with
arXiv:0904.369
- …