521 research outputs found
High temperature be panel development
Beryllium materials have been used for many aerospace applications over the years. Most of these applications have been fairly ambient environments. The possibility of fabricating beryllium panels for high temperature applications up to 1200 F is investigated. Joining alloys were reviewed, tested and evaluated for high temperature applications
Epstein-Barr virus infections and DNA hybridization studies in posttransplantation lymphoma and lymphoproliferative lesions: The role of primary infection
Fourteen patients who developed B cell lymphomas or lymphoproliferative lesions after kidney, liver, heart, or heart-lung transplantation in Pittsburgh during 1981-1983 had active infection with Epstein-Barr virus (EBV)of the primary (six patients), reactivated (seven patients), or chronic (one patient) type. In transplant patients without tumors, the incidence of EBV infection was 30% (39 of 128). Only three of these patients had primary infections. Thus the frequency of active infection was significantly higher in patients with tumors, and patients with primary infections were at greater risk of developing tumors. Five of 13 tumors tested contained EBV nuclear antigen (EBNA) and nine of 11 contained EBV genomes detected by DNA-DNA hybridization with BamHI K, BamHI W, or EcoRI B cloned probes. All EBNA-positive tumors, except one, were also positive by hybridization. Only one tumor was negative for both EBNA and EBV DNA. These data suggest that EBV plays an etiologic role in the development of these lesions. © 1985 by The University of Chicago
Reversibility of lymphomas and lymphoproliferative lesions developing under cyclosporin-steroid therapy
Post-transplant lymphomas or other lymphoproliferative lesions, which were usually associated with Epstein-Barr virus infections, developed in 8, 4, 3, and 2 recipients, respectively, of cadaveric kidney, liver, heart, and heart-lung homografts. Reduction or discontinuance of immunosuppression caused regression of the lesions, often without subsequent rejection of the grafts. Chemotherapy and irradiation were not valuable. The findings may influence policies about treating other kinds of post-transplantation neoplasms
Recommended from our members
Feasibility of tropospheric water vapor profiling using infrared heterodyne differential absorption lidar
Continuous, high quality profiles of water vapor, free of systematic bias, and of moderate temporal and spatial resolution, acquired over long periods at low operational and maintenance cost, are fundamental to the success of the ARM CART program. The development and verification of realistic climate model parameterizations for clouds and net radiation balance, and the correction of other CART site sensor observations for interferences due to the presence of water vapor are critically dependent on water vapor profile measurements. Application of profiles acquired with current techniques, have, to date, been limited by vertical resolution and uniqueness of solution [e.g. high resolution infrared (IR) Fourier transform radiometry], poor spatial and temporal coverage and high operating cost (e.g. radiosondes), or diminished daytime performance, lack of eye-safety, and high maintenance cost (e.g. Raman lidar). Recent developments in infrared laser and detector technology make possible compact IR differential absorption lidar (DIAL) systems at eye-safe wavelengths. In the study reported here, we develop DIAL system performance models and examine the potential of to solve some of the shortcomings of previous methods using parameterizations representative of current technologies. These models are also applied to diagnose and evaluate other strengths and weaknesses unique to the DIAL method for this application. This work is to continue in the direction of evaluating yet smaller and lower-cost laser diode-based systems for routine monitoring of the lower altitudes using photon counting detection methods. We regard the present report as interim in nature and will update and extend it as a final report at the end of the term of the contract
From fire suppression to fire management:Advances and resistances to changes in fire policy in the savannas of Brazil and Venezuela
International audienc
Field demonstration of simultaneous wind and temperaturemeasurements from 5to50 km with a Na double-edge magneto-optic filter in a multi-frequency Doppler lidar
We report the first (to our knowledge) field demonstration of simultaneous wind and temperature measurements with a Na double-edge magneto-optic filter implemented in the receiver of a three-frequency Na Doppler lidar. Reliable winds and temperatures were obtained in the altitude range of 10-45 km with 1 km resolution and 60 min integration under the conditions of 0.4 W lidar power and 75 cm telescope aperture. This edge filter with a multi-frequency lidar concept can be applied to other direct-detection Doppler lidars for profiling both wind and temperature simultaneously from the lower to the upper atmosphere
Overview of the Second Texas Air Quality Study (TexAQS II) and the Gulf of Mexico Atmospheric Composition and Climate Study (GoMACCS)
The Second Texas Air Quality Study (TexAQS II) was conducted in eastern Texas during 2005 and 2006. This 2-year study included an intensive field campaign, TexAQS 2006/Gulf of Mexico Atmospheric Composition and Climate Study (GoMACCS), conducted in August–October 2006. The results reported in this special journal section are based on observations collected on four aircraft, one research vessel, networks of ground-based air quality and meteorological (surface and radar wind profiler) sites in eastern Texas, a balloon-borne ozonesonde-radiosonde network (part of Intercontinental Transport Experiment Ozonesonde Network Study (IONS-06)), and satellites. This overview paper provides operational and logistical information for those platforms and sites, summarizes the principal findings and conclusions that have thus far been drawn from the results, and directs readers to appropriate papers for the full analysis. Two of these findings deserve particular emphasis. First, despite decreases in actual emissions of highly reactive volatile organic compounds (HRVOC) and some improvements in inventory estimates since the TexAQS 2000 study, the current Houston area emission inventories still underestimate HRVOC emissions by approximately 1 order of magnitude. Second, the background ozone in eastern Texas, which represents the minimum ozone concentration that is likely achievable through only local controls, can approach or exceed the current National Ambient Air Quality Standard of 75 ppbv for an 8-h average. These findings have broad implications for air quality control strategies in eastern Texas
Assessing the optimized precision of the aircraft mass balance method for measurement of urban greenhouse gas emission rates through averaging
To effectively address climate change, aggressive mitigation policies need to be implemented to reduce greenhouse gas emissions. Anthropogenic carbon emissions are mostly generated from urban environments, where human activities are spatially concentrated. Improvements in uncertainty determinations and precision of measurement techniques are critical to permit accurate and precise tracking of emissions changes relative to the reduction targets. As part of the INFLUX project, we quantified carbon dioxide (CO2), carbon monoxide (CO) and methane (CH4) emission rates for the city of Indianapolis by averaging results from nine aircraft-based mass balance experiments performed in November-December 2014. Our goal was to assess the achievable precision of the aircraft-based mass balance method through averaging, assuming constant CO2, CH4 and CO emissions during a three-week field campaign in late fall. The averaging method leads to an emission rate of 14,600 mol/s for CO2, assumed to be largely fossil-derived for this period of the year, and 108 mol/s for CO. The relative standard error of the mean is 17% and 16%, for CO2 and CO, respectively, at the 95% confidence level (CL), i.e. a more than 2-fold improvement from the previous estimate of ~40% for single-flight measurements for Indianapolis. For CH4, the averaged emission rate is 67 mol/s, while the standard error of the mean at 95% CL is large, i.e. ±60%. Given the results for CO2 and CO for the same flight data, we conclude that this much larger scatter in the observed CH4 emission rate is most likely due to variability of CH4 emissions, suggesting that the assumption of constant daily emissions is not correct for CH4 sources. This work shows that repeated measurements using aircraft-based mass balance methods can yield sufficient precision of the mean to inform emissions reduction efforts by detecting changes over time in urban emissions
The comparison of cytotoxicity of the anticancer drugs doxorubicin and ellipticine to human neuroblastoma cells
Ellipticine is an antineoplastic agent, whose mode of action is based mainly on DNA intercalation, inhibition of topoisomerase II and formation of covalent DNA adducts mediated by cytochromes P450 and peroxidases. Here, the cytotoxicity of ellipticine to human neuroblastoma derived cell lines IMR-32 and UKF-NB-4 was investigated. Treatment of neuroblastoma cells with ellipticine was compared with that of these cancer cells with doxorubicin. The toxicity of ellipticine was essentially the same as that of doxorubicin to UKF-NB-4 cells, but doxorubicin is much more effective to inhibit the growth of the IMR-32 cell line than ellipticine. Hypoxic conditions used for the cell cultivation resulted in a decrease in ellipticine and/or doxorubicin toxicity to IMR-32 and UKF-NB-4 neuroblastoma cells
- …