11,880 research outputs found

    Tomography by noise

    Full text link
    We present an efficient and robust method for the reconstruction of photon number distributions by using solely thermal noise as a probe. The method uses a minimal number of pre-calibrated quantum devices, only one on/off single-photon detector is sufficient. Feasibility of the method is demonstrated by the experimental inference of single-photon, thermal and two-photon states. The method is stable to experimental imperfections and provides a direct, user-friendly quantum diagnostics tool

    The intrinsic electrical equivalent circuit of a laser diode

    Get PDF
    The basic electrical equivalent circuit of a laser diode is derived. The effects of spontaneous emission and self-pulsations are included. It is found that self-pulsations are represented by a negative resistance in the model. Application of this model suggests purely electronic methods of suppressing relaxation oscillations in laser diodes

    Stratosphere aerosol and cloud measurements at McMurdo Station Antarctica during the spring of 1987

    Get PDF
    Measurements of stratospheric aerosols with balloonborne optical particle counters on 6 occasions at McMurdo Station (78 deg S) in the spring of 1986 indicated subsidence of the stratospheric sulfate layer during the time that the ozone hole was forming (Hofmann et al., 1988). Since dynamic models of ozone depletion involving upwelling in the spring polar vortex would suggest the opposite, we repeated the measurements with an increased frequency (about one sounding per week) in 1987. During 3 of the aerosol soundings in 1986, temperatures in the 15 to 20 km range were low enough (less than 80 C) for HNO3 to co-condense with water according to several theories of polar stratospheric cloud formation. However, particles were not observed with the characteristic size suggested by theory (approx. 0.5 microns). For this reason, it was proposed that polar stratospheric clouds may predominantly consist of large (approx. 5 to 50 microns) ice crystals at very low (approx. 10 sup 4- 10 sup 3 cm cubed) concentrations (Rosen et al., 1988). The particle counter employed would be relatively insensitive to these low concentrations. With the increased frequency of soundings in 1987, and adding additional size discrimination in the 1 to 2 micron region, this hypothesis could be verified if suitably low temperatures were encountered

    Experimental Characterization of Turbulent Flow Around Cylinder Arrays

    Get PDF
    This research was done as part of an effort to develop alternative fire suppressant technologies for aircraft engine nacelles. A circular cylinder array was designed, built, and placed in the AFIT roll-around low speed wind tunnel to model generic clutter inside an engine nacelle. A turbulence grid was fabricated to enable measurements of the effects of turbulence level, independent of airspeed, on the flow over different model configurations. The wind tunnel test section was 12 inches wide x 12 inches high x 24 inches long. Pressure differential measurements were taken on various cylinder configurations. The configurations included one cylinder as well as one, two, and three arrays of cylinders. Half diameter spacing was used for two and three cylinder cases, as well as an additional case at a two-diameter spacing with the three array configuration. All conditions were tested with and without the turbulence grid placed at the front of the test section. Pressure differential measurements were taken at 15-degree increments from 0 degrees - 180 degrees on the circumference of an upstream cylinder, centered vertically on the array. Hot-wire measurements were taken with and without the turbulence grid to determine airspeed and the effect of turbulence intensity generated by the grid on the wake profile. Also, vertical traverse data was taken with the hot-wire to determine airflow characteristics behind two configurations, both with and without a turbulence grid. The first had only one cylinder installed while the second was done with three arrays spaced at a half-diameter length. Pressure and velocity measurements were used to investigate the effects caused by the upstream turbulence grid

    Self-organizing particle systems

    Get PDF
    This is a pre-copyedited, author-produced PDF of an article accepted for publication in Advances in Complex Systems following peer review. The version of record, Malte Harder and Daniel Polani, ‘Self-organizing particle systems’, Advs. Complex Syst. 16, 1250089, published October 22, 2012, is available online via doi: https://doi.org/10.1142/S0219525912500890 Published by World Scientific Publishing.The self-organization of cells into a living organism is a very intricate process. Under the surface of orchestrating regulatory networks there are physical processes which make the information processing possible, that is required to organize such a multitude of individual entities. We use a quantitative information theoretic approach to assess self-organization of a collective system. In particular, we consider an interacting particle system, that roughly mimics biological cells by exhibiting differential adhesion behavior. Employing techniques related to shape analysis, we show that these systems in most cases exhibit self-organization. Moreover, we consider spatial constraints of interactions, and additionaly show that particle systems can self-organize without the emergence of pattern-like structures. However, we will see that regular pattern-like structures help to overcome limitations of self-organization that are imposed by the spatial structure of interactions.Peer reviewe

    The UW digital ozonesonde: Characteristics and flow rate calibration

    Get PDF
    During the austral springs of 1986 and 1987, a series of balloon soundings were conducted to characterize the temporal and vertical development of Antarctic ozone depletion using the electrochemical concentration cell method (ECC). An important part of this study was to perform correlative studies between ozone and aerosol particles. In order to facilitate these simultaneous measurements, a digital ozonesonde system was developed to interface with aerosol counters. The ozone measurements will be described herein. The ozonesonde modification was accomplished by converting the current output of the sonde to a frequency and adding this digital signal to the serial data stream of a Vaisala Corporation RS-80 radiosonde under microprocessor control. A number of advantages over the standard ozonesonde system currently in use are noted

    The oxygen-independent metabolism of cyclic monoterpenes in Castellaniella defragrans 65Phen

    Get PDF
    BACKGROUND: The facultatively anaerobic betaproteobacterium Castellaniella defragrans 65Phen utilizes acyclic, monocyclic and bicyclic monoterpenes as sole carbon source under oxic as well as anoxic conditions. A biotransformation pathway of the acyclic β-myrcene required linalool dehydratase-isomerase as initial enzyme acting on the hydrocarbon. An in-frame deletion mutant did not use myrcene, but was able to grow on monocyclic monoterpenes. The genome sequence and a comparative proteome analysis together with a random transposon mutagenesis were conducted to identify genes involved in the monocyclic monoterpene metabolism. Metabolites accumulating in cultures of transposon and in-frame deletion mutants disclosed the degradation pathway. RESULTS: Castellaniella defragrans 65Phen oxidizes the monocyclic monoterpene limonene at the primary methyl group forming perillyl alcohol. The genome of 3.95 Mb contained a 70 kb genome island coding for over 50 proteins involved in the monoterpene metabolism. This island showed higher homology to genes of another monoterpene-mineralizing betaproteobacterium, Thauera terpenica 58Eu(T), than to genomes of the family Alcaligenaceae, which harbors the genus Castellaniella. A collection of 72 transposon mutants unable to grow on limonene contained 17 inactivated genes, with 46 mutants located in the two genes ctmAB (cyclic terpene metabolism). CtmA and ctmB were annotated as FAD-dependent oxidoreductases and clustered together with ctmE, a 2Fe-2S ferredoxin gene, and ctmF, coding for a NADH:ferredoxin oxidoreductase. Transposon mutants of ctmA, B or E did not grow aerobically or anaerobically on limonene, but on perillyl alcohol. The next steps in the pathway are catalyzed by the geraniol dehydrogenase GeoA and the geranial dehydrogenase GeoB, yielding perillic acid. Two transposon mutants had inactivated genes of the monoterpene ring cleavage (mrc) pathway. 2-Methylcitrate synthase and 2-methylcitrate dehydratase were also essential for the monoterpene metabolism but not for growth on acetate. CONCLUSIONS: The genome of Castellaniella defragrans 65Phen is related to other genomes of Alcaligenaceae, but contains a genomic island with genes of the monoterpene metabolism. Castellaniella defragrans 65Phen degrades limonene via a limonene dehydrogenase and the oxidation of perillyl alcohol. The initial oxidation at the primary methyl group is independent of molecular oxygen

    Hall current accelerator Final report, 10 Jun. 1964 - 10 Sep. 1965

    Get PDF
    Axisymmetric Hall current accelerator as electric spacecraft propulsion syste

    Ozone profile measurements at McMurdo Station Antarctica during the spring of 1987

    Get PDF
    During the Antarctic spring of 1986, 33 ozone soundings were conducted from McMurdo Station. These data indicated that the springtime decrease in ozone occurred rapidly between the altitudes of 12 and 20 km. During 1987, these measurements were repeated with 50 soundings between 29 August and 9 November. Digital conversions of standard electrochemical cell ozonesondes were again employed. The ozonesonde pumps were individually calibrated for flow rate as the high altitude performance of these pumps have been in question. While these uncertainties are not large in the region of the ozone hole, they are significant at high altitude and apparently resulted in an underestimate of total ozone of about 7 percent (average) as compared to the Total Ozone Mapping Spectrometer (TOMS) in 1986, when the flow rate recommended by the manufacturer was used. At the upper altitudes (approx. 30 km) the flow rate may be overestimated by as much as 15 percent using recommended values (see Harder et al., The UW Digital Ozonesonde: Characteristics and Flow Rate Calibration, poster paper, this workshop). These upper level values are used in the extrapolation, at constant mixing ratio, required to complete the sounding for total ozone. The first sounding was on 29 August, prior to major ozone depletion, when 274 DU total ozone (25 DU extrapolated) was observed. By early October total ozone had decreased to the 150 DU range; it then increased during mid-October owing to motion of the vortex and returned to a value of 148 DU (29 DU extrapolated) on 27 October
    corecore