76 research outputs found

    New developments in fabrication of high-energy-resolution analyzers for inelastic X-ray spectroscopy

    Get PDF
    New improvements related to the fabrication of spherical bent analyzers for 1 meV energy-resolution inelastic X-ray scattering spectroscopy are presented

    Effect of carbon nanofibre orientation on fatigue properties of carbon fibre-reinforced polymers

    Get PDF
    Nano-reinforcements in carbon fibre-reinforced polymer (CFRP) have proven to enhance the mechanical properties considering quasi-static, as well as fatigue load and, are a promising option with regard to CFRP performance optimisation. While general knowledge about the nanofiller content and its influence in CFRP is well documented, the use of alignment techniques for a specific orientation of the nano-reinforcements is still insufficiently studied. In this work, the influence of oriented carbon nanofibres (CNF) on the mechanical properties of bidirectional CFRP is investigated. CFRP was produced CNF-reinforced with and without orientation using a hot press, where an electric field was applied during curing. The laminates were characterised with respect to dispersion quality, pore volume, quasi-static properties (tensile and bending tests) and dynamic properties (fatigue tests). Electrical resistance measurement was applied together with digital image correlation and in situ computed tomography to generate knowledge about the fatigue-related damage evolution and evaluate the sensors for viable use of condition monitoring. Results show that the orientation of CNF has a significant impact on both quasi-static and fatigue properties, increasing the strength while reducing and slowing down the introduced damage. Orientation of nanofillers thus shows large optimization potential of mechanical properties of CFRP components

    A split and delay unit for the European XFEL

    Get PDF
    For the European XFEL [1] an x ray split and delay unit SDU is built covering photon energies from 5 keV up to 20 keV [2]. This SDU will enable time resolved x ray pump x ray probe experiments as well as sequential diffractive imaging [3] on a femtosecond to picosecond time scale. Further, direct measurements of the temporal coherence properties will be possible by making use of a linear autocorrelation. The set up is based on geometric wavefront beam splitting, which has successfully been implemented at an autocorrelator at FLASH [4]. The x ray FEL pulses will be split by a sharp edge of a silicon mirror coated with Mo B4C multi layers. Both partial beams will then pass variable delay lines. For different wavelengths the angle of incidence onto the multilayer mirrors will be adjusted in order to match the Bragg condition. For a photon energy of h 20 keV a grazing angle of 0.57 has to be set, which results in a footprint of the beam on the mirror of l 120 mm. At this photon energy the reflectance of a Mo B4 C multi layer coating with a multi layer period of d 3.2 nm and N 200 layers amounts to R 0.92. In order to enhance the maximum transmission for photon energies of h 8 keV and below, a Ni B4C multilayer coating can be applied beside the Mo B4C coating for this spectral region. Because of the different incidence angles, the path lengths of the beams will differ as a function of wavelength. Hence, maximum delays between 2.5 ps at h 20 keV and up to 23 ps at h 5 keV will be possibl

    WavePropaGator

    Get PDF
    The WavePropaGatorWavePropaGator (WPG) package is a new interactive cross-platform open-source software framework for modeling of coherent and partially coherent X-ray wavefront propagation. The WPG addresses the needs of beamline scientists and user groups to facilitate the design, optimization and improvement of X-ray optics to meet their experimental requirements. The paper presents a general description of the package and gives some recent application examples

    Superconducting undulator activities at the European X-ray Free-Electron Laser Facility

    Get PDF
    For more than 5 years, superconducting undulators (SCUs) have been successfully delivering X-rays in storage rings. The European X-Ray Free-Electron Laser Facility (XFEL) plans to demonstrate the operation of SCUs in X-ray free-electron lasers (FELs). For the same geometry, SCUs can reach a higher peak field on the axis with respect to all other available technologies, offering a larger photon energy tunability range. The application of short-period SCUs in a high electron beam energy FEL > 11 GeV will enable lasing at very hard X-rays > 40 keV. The large tunability range of SCUs will allow covering the complete photon energy range of the soft X-ray experiments at the European XFEL without changing electron beam energy, as currently needed with the installed permanent magnet undulators. For a possible continuous-wave (CW) upgrade under discussion at the European XFEL with a lower electron beam energy of approximately 7–8 GeV, SCUs can provide the same photon energy range as available at present with the permanent magnet undulators and electron energies. This paper will describe the potential of SCUs for X-ray FELs. In particular, it will focus on the different activities ongoing at the European XFEL and in collaboration with DESY to allow the implementation of SCUs in the European XFEL in the upcoming years

    Current Account Imbalances and Structural Adjustment in the Euro Area: How to Rebalance Competitiveness

    Full text link
    Low international competitiveness of a set of euro area countries, which have become evident by large current account deficits and rising risk premiums on government bonds, is one of the most challenging economic policy issues for Europe. We analyse the role of private restructuring and public structural reforms for the urgently needed readjustment of intra-euro area imbalances. A panel regression reveals a significant impact of private restructuring and public structural reforms on intra-euro area competitiveness. This implies that private restructuring and public reforms are rather than public transfers the best way to preserve long-term economic stability in Europe

    The soft x-ray instrument for materials studies at the linac coherent light source x-ray free-electron laser

    Get PDF
    This content may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This material originally appeared in Review of Scientific Instruments 83, 043107 (2012) and may be found at https://doi.org/10.1063/1.3698294.The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480–2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser
    • …
    corecore