443 research outputs found

    PIH12 A Descriptive Study of Health Related Quality of Life among General Population of Quetta, Pakistan

    Get PDF

    A study of frequency and pulses for stepper motor controller system by using programmable logic controller

    Get PDF
    The stepper motor movement process produced different frequency and pulses. This research explained about the frequency and pulses for the stepper motor movement by using Programmable Logic Controller (PLC) as research method. The study was done to find the suitable frequency and pulses for stepper motor movement by developing a prototype stepper motor controller system. The pulse frequency used did not affected the distance of moving load in the stepper motor operations. The increasing number of pulse frequency only will affect the time taken for the stepper motor to complete its operations. The result showed that number of pulse frequency at high operation was 5000 Hz. Pulse number reacted as a manipulated variable that affected both factor which is time taken of stepper motor operation and the distance of moving load

    Pro-poor intervention strategies in irrigated agriculture in Asia: poverty in irrigated agriculture: issues and options: Bangladesh

    Get PDF
    Irrigated farming / Poverty / Irrigation management / Water resource management / Policy / Planning / Institutions / Organizations / Local government / Non-governmental organizations / Legislation / Water users / Participatory management / Public sector / Water allocation / Cost recovery / Households / Income / Expenditure / Irrigation canals / Bangladesh

    Photoionisation loading of large Sr+ ion clouds with ultrafast pulses

    Get PDF
    This paper reports on photoionisation loading based on ultrafast pulses of singly-ionised strontium ions in a linear Paul trap. We take advantage of an autoionising resonance of Sr neutral atoms to form Sr+ by two-photon absorption of femtosecond pulses at a wavelength of 431nm. We compare this technique to electron-bombardment ionisation and observe several advantages of photoionisation. It actually allows the loading of a pure Sr+ ion cloud in a low radio-frequency voltage amplitude regime. In these conditions up to 4x10^4 laser-cooled Sr+ ions were trapped

    Civic Nationalism and Language-in-Education Policies in the United Arab Emirates

    Get PDF
    A founding principle of the United Arab Emirates is the belief that tolerance promotes peace, while isolation encourages division and conflict. With more than 200 nationalities residing in the UAE, Emiratis constitute only 10% of the population, making them a minority in their own country. Despite the government promoting diversity and tolerance as the norm, such demographic imbalance come with a cost to the Arabic language, the national identity and culture, and the education system. This chapter addresses those concerns through a series of recent government initiatives. The author classifies neo-nationalist movements into different types, arguing that the one in the UAE largely fits within the civic type with its non-hostile, overall welcoming attitude toward foreigners. At the end of the chapter, she discusses the impact of neo-nationalism on education and calls for clearer policies that take into account language(s) as a right and as a resource

    Reciprocity? International Preceptors’ Perceptions of Global Health Elective Learners at African Sites

    Get PDF
    Background: Short-term global health electives (STGHEs) have become increasingly common, with evidence showing educational and clinical benefits for short-term learners (STLs). Despite increased recognition that STGHEs should be mutually beneficial for host sites and STLs, evidence demonstrating the impact on international host preceptors is lacking. Objectives: To understand international host preceptors’ perceptions regarding benefits and burdens of hosting STLs. Methods: Focus group discussions with a convenience sample of 10 of 18 eligible preceptors were conducted at pediatric STGHE sites in Malawi and Lesotho. Qualitative content analysis was performed to identify themes using a deductive-inductive approach. Findings: Common themes regarding benefits to preceptors included increased knowledge and resources for learning from STLs, broadened differential diagnoses, and the satisfaction of teaching. Regarding burdens, preceptors perceived that supervising STLs decreases efficiency. Preceptors identified the burden of having to intervene in instances that could lead to patient harm. Some preceptors perceived that STLs under-valued preceptors’ clinical decision-making in resource-limited contexts. Conclusions: Our findings emphasize the need for institutions to identify mutuality of benefits between STLs and host sites when developing STGHEs. Host preceptors identified robust pre-departure training for STLs, lengthened duration of STGHEs, and formal preceptor orientation as ways to enhance mutuality of benefits

    Development and evaluation of machine learning in whole-body magnetic resonance imaging for detecting metastases in patients with lung or colon cancer: a diagnostic test accuracy study.

    Get PDF
    OBJECTIVES: Whole-body magnetic resonance imaging (WB-MRI) has been demonstrated to be efficient and cost-effective for cancer staging. The study aim was to develop a machine learning (ML) algorithm to improve radiologists' sensitivity and specificity for metastasis detection and reduce reading times. MATERIALS AND METHODS: A retrospective analysis of 438 prospectively collected WB-MRI scans from multicenter Streamline studies (February 2013-September 2016) was undertaken. Disease sites were manually labeled using Streamline reference standard. Whole-body MRI scans were randomly allocated to training and testing sets. A model for malignant lesion detection was developed based on convolutional neural networks and a 2-stage training strategy. The final algorithm generated lesion probability heat maps. Using a concurrent reader paradigm, 25 radiologists (18 experienced, 7 inexperienced in WB-/MRI) were randomly allocated WB-MRI scans with or without ML support to detect malignant lesions over 2 or 3 reading rounds. Reads were undertaken in the setting of a diagnostic radiology reading room between November 2019 and March 2020. Reading times were recorded by a scribe. Prespecified analysis included sensitivity, specificity, interobserver agreement, and reading time of radiology readers to detect metastases with or without ML support. Reader performance for detection of the primary tumor was also evaluated. RESULTS: Four hundred thirty-three evaluable WB-MRI scans were allocated to algorithm training (245) or radiology testing (50 patients with metastases, from primary 117 colon [n = 117] or lung [n = 71] cancer). Among a total 562 reads by experienced radiologists over 2 reading rounds, per-patient specificity was 86.2% (ML) and 87.7% (non-ML) (-1.5% difference; 95% confidence interval [CI], -6.4%, 3.5%; P = 0.39). Sensitivity was 66.0% (ML) and 70.0% (non-ML) (-4.0% difference; 95% CI, -13.5%, 5.5%; P = 0.344). Among 161 reads by inexperienced readers, per-patient specificity in both groups was 76.3% (0% difference; 95% CI, -15.0%, 15.0%; P = 0.613), with sensitivity of 73.3% (ML) and 60.0% (non-ML) (13.3% difference; 95% CI, -7.9%, 34.5%; P = 0.313). Per-site specificity was high (>90%) for all metastatic sites and experience levels. There was high sensitivity for the detection of primary tumors (lung cancer detection rate of 98.6% with and without ML [0.0% difference; 95% CI, -2.0%, 2.0%; P = 1.00], colon cancer detection rate of 89.0% with and 90.6% without ML [-1.7% difference; 95% CI, -5.6%, 2.2%; P = 0.65]). When combining all reads from rounds 1 and 2, reading times fell by 6.2% (95% CI, -22.8%, 10.0%) when using ML. Round 2 read-times fell by 32% (95% CI, 20.8%, 42.8%) compared with round 1. Within round 2, there was a significant decrease in read-time when using ML support, estimated as 286 seconds (or 11%) quicker (P = 0.0281), using regression analysis to account for reader experience, read round, and tumor type. Interobserver variance suggests moderate agreement, Cohen Îş = 0.64; 95% CI, 0.47, 0.81 (with ML), and Cohen Îş = 0.66; 95% CI, 0.47, 0.81 (without ML). CONCLUSIONS: There was no evidence of a significant difference in per-patient sensitivity and specificity for detecting metastases or the primary tumor using concurrent ML compared with standard WB-MRI. Radiology read-times with or without ML support fell for round 2 reads compared with round 1, suggesting that readers familiarized themselves with the study reading method. During the second reading round, there was a significant reduction in reading time when using ML support

    Measurement of the rate of nu_e + d --> p + p + e^- interactions produced by 8B solar neutrinos at the Sudbury Neutrino Observatory

    Get PDF
    Solar neutrinos from the decay of 8^8B have been detected at the Sudbury Neutrino Observatory (SNO) via the charged current (CC) reaction on deuterium and by the elastic scattering (ES) of electrons. The CC reaction is sensitive exclusively to nu_e's, while the ES reaction also has a small sensitivity to nu_mu's and nu_tau's. The flux of nu_e's from ^8B decay measured by the CC reaction rate is \phi^CC(nu_e) = 1.75 +/- 0.07 (stat)+0.12/-0.11 (sys.) +/- 0.05(theor) x 10^6 /cm^2 s. Assuming no flavor transformation, the flux inferred from the ES reaction rate is \phi^ES(nu_x) = 2.39+/-0.34 (stat.)+0.16}/-0.14 (sys) x 10^6 /cm^2 s. Comparison of \phi^CC(nu_e) to the Super-Kamiokande Collaboration's precision value of \phi^ES(\nu_x) yields a 3.3 sigma difference, providing evidence that there is a non-electron flavor active neutrino component in the solar flux. The total flux of active ^8B neutrinos is thus determined to be 5.44 +/-0.99 x 10^6/cm^2 s, in close agreement with the predictions of solar models.Comment: 6 pages (LaTex), 3 figures, submitted to Phys. Rev. Letter

    Secondary Endoleak Management Following TEVAR and EVAR.

    Get PDF
    Endovascular abdominal and thoracic aortic aneurysm repair and are widely used to treat increasingly complex aneurysms. Secondary endoleaks, defined as those detected more than 30 days after the procedure and after previous negative imaging, remain a challenge for aortic specialists, conferring a need for long-term surveillance and reintervention. Endoleaks are classified on the basis of their anatomic site and aetiology. Type 1 and type 2 endoleaks (EL1 and EL2) are the most common endoleaks necessitating intervention. The management of these requires an understanding of their mechanics, and the risk of sac enlargement and rupture due to increased sac pressure. Endovascular techniques are the main treatment approach to manage secondary endoleaks. However, surgery should be considered where endovascular treatments fail to arrest aneurysm growth. This chapter reviews the aetiology, significance, management strategy and techniques for different endoleak types
    • …
    corecore