6 research outputs found

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Effect of alendronic acid on fracture healing: A multicenter randomized placebo-controlled trial

    Get PDF
    There is a concern that bisphosphonates may impair fracture healing because of their inhibitory effects on bone turnover. Here we evaluated the effects of early bisphosphonate therapy on fracture healing and functional outcome following a fracture of the distal radius. The fracture and bisphosphonates (FAB) trial was a double-blind, randomized, placebo-controlled trial involving 15 trauma centers in the United Kingdom. We enrolled 421 bisphosphonate-naive patients aged ≥50 years with a radiographically confirmed fracture of the distal radius and randomized them in a 1:1 ratio to receive alendronic acid 70 mg once weekly (n = 215) or placebo (n = 206) within 14 days of the fracture. The primary outcome measure was the proportion of fractures that had radiologically united at 4 weeks as assessed by an observer, blinded to treatment allocation. Secondary outcomes included the Disabilities of the Arm Shoulder and Hand (DASH) questionnaire, range of wrist movement and grip strength, pain and analgesia requirements, and the rate of malunion. The mean ± SD age of participants was 63 ± 8.5 years and 362 (86%) were female. At 4 weeks, 48 of 202 (23.8%) fractures had united in the alendronic acid group compared with 52 of 187 (27.8%) in the placebo group (observed absolute proportion difference 4.0%; 95% CI, -4.7% to 12.8%; p = 0.36). The absolute proportion difference between groups based on imputed data was 4.5% (95% CI, -4.7% to 13.8%; p = 0.30). There was no significant difference in the proportion of fractures that had united at any other time point and no differences in the DASH score, pain at the fracture site, grip strength, or any other clinical outcome. We conclude that among patients aged 50 years and above with a distal radius fracture, early administration of alendronic acid does not adversely affect fracture union or clinical outcome. These findings suggest bisphosphonate therapy can be safely commenced early after fracture if clinically indicated

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial.

    No full text
    Item does not contain fulltex

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar
    corecore