8 research outputs found

    Evaluation of the safety and efficacy of an edoxaban-based antithrombotic regimen in patients with atrial fibrillation following successful percutaneous coronary intervention (PCI) with stent placement: Rationale and design of the ENTRUST-AF PCI trial.

    Get PDF
    BACKGROUND The optimal antithrombotic treatment after percutaneous coronary intervention (PCI) with stenting in patients with atrial fibrillation (AF) is unknown. In the ENGAGE AF-TIMI 48 trial, edoxaban was noninferior to a vitamin K antagonist (VKA) with respect to the prevention of stroke or systemic embolism and was associated with significantly lower rates of bleeding and cardiovascular death in patients with nonvalvular AF. The effects of edoxaban in combination with single- or dual-antiplatelet therapy in the setting of PCI are unexplored. DESIGN The ENTRUST-AF PCI trial is a multinational, multicenter, randomized, open-label phase 3b trial with blinded end point evaluation involving 1,500 patients on oral anticoagulation for AF. Patients are randomized between 4 hours and 5 days after successful PCI to either an edoxaban-based strategy (experimental arm; 60 mg [or 30 mg according to dose reduction criteria] once daily plus a P2Y antagonist [default clopidogrel, 75 mg once daily] for 12 months) or a VKA-based strategy (control arm; VKA plus a P2Y antagonist [as above] plus acetylsalicylic acid [100 mg once daily] for 30 days to 12 months). The primary safety end point is the incidence of International Society on Thrombosis and Haemostasis-defined major or clinically relevant nonmajor bleeding. The main efficacy end point is the composite of cardiovascular death, stroke, systemic embolic events, spontaneous myocardial infarction, and definite stent thrombosis. SUMMARY The ENTRUST-AF PCI trial tests the hypothesis that an edoxaban-based antithrombotic strategy reduces the risk of bleeding complications after PCI compared with VKA plus conventional dual-antiplatelet therapy in patients with AF in need of oral anticoagulation. The relative risk of ischemic events between groups will be compared

    Edoxaban and implantable cardiac device interventions: insights from the ENGAGE AF-TIMI 48 trial

    Full text link
    Aims Pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy device implantations and generator changes are frequently performed in patients receiving direct oral anticoagulants. In an exploratory analysis, we investigated the outcome of patients undergoing such device procedures in the ENGAGE AF-TIMI 48 trial. Methods and results During the trial, 1217 device procedures were performed in 1145 patients, with intervention dates available for 1203 procedures. Two hundred and twenty-five procedures (in 212 patients) were performed >30 days after study drug was stopped and are not included in the event analysis. For most interventions (n = 728, 74%), study drug was interrupted >3 days (median for the entire cohort: 5 days, interquartile range 0-11 days); 250 interventions were performed with ≀3 days study drug interruption. During the first 30 days after the procedure, six strokes/systemic embolic events (SEEs) (three each in the lower-dose edoxaban and warfarin arm) and one major bleeding event (in the lower-dose edoxaban arm) occurred; no stroke/SEEs or major bleeds occurred around the 295 device procedures in the higher-dose edoxaban arm. Two ischaemic and one major bleeding event occurred after the 288 device procedures performed with ≀3 days periprocedural interruption of study drug. Conclusion In this first experience of patients undergoing device surgery with edoxaban, a low risk of ischaemic and bleeding events was observed during the first 30 days post-procedure. Our data are in line with current recommendations of no or only brief interruption of non-vitamin K antagonist oral anticoagulants prior to cardiac device surgery

    Optically Triggered NĂ©el Vector Manipulation of a Metallic Antiferromagnet Mn2Au under Strain

    No full text
    International audienceThe absence of stray fields, their insensitivity to external magnetic fields, and ultrafast dynamics make antiferromagnets promising candidates for active elements in spintronic devices. Here, we demonstrate manipulation of the NĂ©el vector in the metallic collinear antiferromagnet Mn2Au by combining strain and femtosecond laser excitation. Applying tensile strain along either of the two in-plane easy axes and locally exciting the sample by a train of femtosecond pulses, we align the NĂ©el vector along the direction controlled by the applied strain. The dependence on the laser fluence and strain suggests the alignment is a result of optically-triggered depinning of 90o domain walls and their sliding in the direction of the free energy gradient, governed by the magneto-elastic coupling. The resulting, switchable, state is stable at room temperature and insensitive to magnetic fields. Such an approach may provide ways to realize robust high-density memory device with switching timescales in the picosecond range

    Evaluation of the safety and efficacy of an edoxaban-based antithrombotic regimen in patients with atrial fibrillation following successful percutaneous coronary intervention (PCI) with stent placement: Rationale and design of the ENTRUST-AF PCI trial

    Get PDF
    Background The optimal antithrombotic treatment after percutaneous coronary intervention (PCI) with stenting in patients with atrial fibrillation (AF) is unknown. In the ENGAGE AF-TIMI 48 trial, edoxaban was noninferior to a vitamin K antagonist (VKA) with respect to the prevention of stroke or systemic embolism and was associated with significantly lower rates of bleeding and cardiovascular death in patients with nonvalvular AF. The effects of edoxaban in combination with singleor dual-antiplatelet therapy in the setting of PCI are unexplored. Design The ENTRUST-AF PCI trial is a multinational, multicenter, randomized, open-label phase 3b trial with blinded end point evaluation involving 1,500 patients on oral anticoagulation for AF. Patients are randomized between 4 hours and 5 days after successful PCI to either an edoxaban-based strategy (experimental arm; 60 mg [or 30 mg according to dose reduction criteria] once daily plus a P2Y12 antagonist [default clopidogrel, 75 mg once daily] for 12 months) or a VKA-based strategy (control arm; VKA plus a P2Y12 antagonist [as above] plus acetylsalicylic acid [100 mg once daily] for 30 days to 12 months). The primary safety end point is the incidence of International Society on Thrombosis and Haemostasis-defined major or clinically relevant nonmajor bleeding. The main efficacy end point is the composite of cardiovascular death, stroke, systemic embolic events, spontaneous myocardial infarction, and definite stent thrombosis. Summary The ENTRUST-AF PCI trial tests the hypothesis that an edoxaban-based antithrombotic strategy reduces the risk of bleeding complications after PCI compared with VKA plus conventional dual-antiplatelet therapy in patients with AF in need of oral anticoagulation. The relative risk of ischemic events between groups will be compare

    Optically Triggered Néel Vector Manipulation of a Metallic Antiferromagnet Mn<sub>2</sub>Au under Strain

    No full text
    The absence of stray fields, their insensitivity to external magnetic fields, and ultrafast dynamics make antiferromagnets promising candidates for active elements in spintronic devices. Here, we demonstrate manipulation of the Néel vector in the metallic collinear antiferromagnet Mn2Au by combining strain and femtosecond laser excitation. Applying tensile strain along either of the two in-plane easy axes and locally exciting the sample by a train of femtosecond pulses, we align the Néel vector along the direction controlled by the applied strain. The dependence on the laser fluence and strain suggests the alignment is a result of optically triggered depinning of 90° domain walls and their motion in the direction of the free energy gradient, governed by the magneto-elastic coupling. The resulting, switchable state is stable at room temperature and insensitive to magnetic fields. Such an approach may provide ways to realize robust high-density memory device with switching time scales in the picosecond range

    German Association of Endocrine Surgeons practice guideline for the surgical management of malignant thyroid tumors

    No full text
    corecore