    Where It’s at Really Matters: In Situ In Vivo Vascular Endothelial Growth Factor Spatially Correlates with Electron Paramagnetic Resonance pO2 Images in Tumors of Living Mice

    Get PDF
    Purpose: Tumor microenvironments show remarkable tumor pO_{2} heterogeneity, as seen in prior EPR pO_{2} images (EPROI). pO_{2} correlation with hypoxia response proteins is frustrated by large rapid pO2 changes with position. Procedures: To overcome this limitation, biopsies stereotactically located in the EPROI were used to explore the relationship between vascular endothelial growth factor A (VEGF) concentrations in living mouse tumors and the local EPROI pO_{2}. Results: Quantitative ELISA VEGF concentrations correlated (p = 0.0068 to 0.019) with mean pO_{2}, median pO_{2}, and the fraction of voxels in the biopsy volume with pO_{2} less than 3, 6, and 10 Torr. Conclusions: This validates EPROI hypoxic fractions at the molecular level and provides a new paradigm for the assessment of the relationship, in vivo, between hypoxia and hypoxia response proteins. When translated to human subjects, this will enhance understanding of human tumor pathophysiology and cancer response to therapy

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Reduction of image artifacts in mice by bladder flushing with a novel double-lumen urethral catheter

    No full text
    In electron paramagnetic resonance imaging (EPRI), the accumulation of contrast agent in the bladder can create a very large source of signal, often far greater than that of the organ of interest. Mouse model images have become increasingly important in preclinical testing. To minimize bladder accumulation on mouse images, we developed a novel, minimally invasive, MRI/EPRI-friendly procedure for flushing a female mouse bladder. It is also applicable to other imaging techniques, for example, PET, SPECT, etc., where contrast agent accumulation in the bladder is also undesirable. A double-lumen urethral catheter was developed, using a standard IV catheter with a silicone tube extension, having a polyethylene tube threaded into the IV catheter. Flushing of the bladder provides a substantial reduction in artifacts, as shown in images of tumors in mice

    Vegetated treatment area (VTAs) efficiencies for E. coli and nutrient removal on small-scale swine operations

    No full text
    As small-scale animal feeding operations work to manage their byproducts and avoid regulation, they need practical, cost-effective methods to reduce environmental impact. One such option is using vegetative treatment areas (VTAs) with perennial grasses to treat runoff; however, research is limited on VTA effectiveness as a waste management alternative for smaller operations. This study evaluated the efficiencies of VTAs in reducing bacteria and nutrient runoff from small-scale swine operations in three counties in Central Texas. Based on 4 yr of runoff data, the Bell and Brazos VTAs significantly reduced loads and concentrations of E. coli and nutrients (except NO3-N) and had treatment efficiencies of 73–94%. Most notably, the Bell VTA reduced loads of E. coli, NH4-N, PO4-P, total N, and total P similar to that of the background (control). In spite of significant reductions, runoff from the Brazos VTA had higher concentrations and loads than the control site, especially following installation of concrete pens and increased pen washing, which produced standing water and increased E. coli and nutrient influx. The Robertson VTA produced fewer significant reductions and had lower treatment efficiencies (29–69%); however, E. coli and nutrient concentrations and loads leaving this VTA were much lower than observed at the Bell and Brazos County sites due to alternative solids management and enclosed pens. Based on these results and previous research, VTAs can be practical, effective waste management alternatives for reducing nutrient and bacteria losses from small-scale animal operations, but only if properly designed and managed. Keywords: Bacteria, Nutrients, Swine manure, Waste management, Water qualit

    Hisstology: High Spectral and

    No full text
    High spectral and spatial resolution (HiSS) data, acquired with echo-planar spectroscopic imaging (EPSI), can be used to acquire water spectra from each small image voxel. These images are sensitive to changes in local susceptibility caused by superparamagnetic iron oxide particles (SPIO); therefore, we hypothesized that images derived from HiSS data are very sensitive to tumor neovasculature following injection of SPIO. Accurate image registration was used to validate HiSS detection of neovasculature with histology and micro-computed tomographic (microCT) angiography. Athymic nude mice and Copenhagen rats were inoculated with Dunning AT6.1 prostate tumor cells in the right hind limb. The tumor region was imaged pre- and post-intravenous injection of SPIO. Three-dimensional assemblies of the CD31-stained histologic slices of the mouse legs and the microCT images of the rat vascular casts were registered with EPSI. The average distance between HiSS-predicted regions of high vascular density on magnetic resonance imaging and CD31-stained regions on histology was 200 μm. Similarly, vessels identified by HiSS in the rat images coincided with vasculature in the registered microCT image. The data demonstrate a strong correlation between tumor vasculature identified using HiSS and two gold standards: histology and microCT angiography

    Reduction of Image Artifacts in Mice by Bladder Flushing with a Novel Double-Lumen Urethral Catheter

    No full text
    In electron paramagnetic resonance imaging (EPRI), the accumulation of contrast agent in the bladder can create a very large source of signal, often far greater than that of the organ of interest. Mouse model images have become increasingly important in preclinical testing. To minimize bladder accumulation on mouse images, we developed a novel, minimally invasive, MRI/EPRI-friendly procedure for flushing a female mouse bladder. It is also applicable to other imaging techniques, for example, PET, SPECT, etc., where contrast agent accumulation in the bladder is also undesirable. A double-lumen urethral catheter was developed, using a standard IV catheter with a silicone tube extension, having a polyethylene tube threaded into the IV catheter. Flushing of the bladder provides a substantial reduction in artifacts, as shown in images of tumors in mice