7 research outputs found

    Mechanical properties of injection-molded thermoplastic denture base resins.

    Get PDF
    OBJECTIVE:To investigate the mechanical properties of injection-molded thermoplastic denture base resins.MATERIAL AND METHODS:Four injection-molded thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were used in this study. The flexural strength at the proportional limit (FS-PL), the elastic modulus, and the Charpy impact strength of the denture base resins were measured according to International Organization for Standardization (ISO) 1567 and ISO 1567:1999/Amd 1:2003.RESULTS:The descending order of the FS-PL was: conventional PMMA > polyethylene terephthalate, polycarbonate > two polyamides. The descending order of the elastic moduli was: conventional PMMA > polycarbonate > polyethylene terephthalate > two polyamides. The descending order of the Charpy impact strength was: polyamide (Nylon PACM12) > polycarbonate > polyamide (Nylon 12), polyethylene terephthalate > conventional PMMA.CONCLUSIONS:All of the injection-molded thermoplastic resins had significantly lower FS-PL, lower elastic moduli, and higher or similar impact strength compared to the conventional PMMA. The polyamide denture base resins had low FS-PL and low elastic moduli; one of them possessed very high impact strength, and the other had low impact strength. The polyethylene terephthalate denture base resin showed a moderately high FS-PL, moderate elastic modulus, and low impact strength. The polycarbonate denture base resin had a moderately high FS-PL, moderately high elastic modulus, and moderate impact strength.福岡歯科大学2013年

    Bond strength of artificial teeth to thermoplastic denture base resin for injection molding.

    Get PDF
    This research was conducted to investigate the bond strength between artificial teeth and a thermoplastic denture base resin for injection molding with different surface preparations for use in flexible resin removable partial dentures. Composite resin denture teeth and acrylic denture resin teeth were bonded to three types of thermoplastic denture base resins for injection molding (polyamide, polyester, and polycarbonate) and a conventional heat-polymerized polymethyl methacrylate (PMMA) resin (control). The ridge lap surfaces of the artificial teeth were classified into four groups based on the type of ridge lap surface treatment applied (n=10): no treatment, ethyl acetate, small T-shaped tunnel, and large T-shaped tunnel. The specimens were tested for bond strength. The results showed that the ethyl acetate treatment was ineffective for enhancing the bond strength (p>0.05) between the artificial teeth and thermoplastic denture base resin for injection molding, whereas the T-shaped tunnel was quite effective in this regard (p<0.05).福岡歯科大学2020年

    Effect of Reinforcement on the Flexural Properties of Injection-Molded Thermoplastic Denture Base Resins.

    Get PDF
    To evaluate the effect of reinforcement on the flexural properties of injection-molded thermoplastic denture base resins.Three injection-molded thermoplastic denture base resins (polyamide, polyester, polycarbonate) were selected for this study, and a conventional heat-polymerized denture base resin (PMMA) was used as a control. Continuous unidirectional glass fiber-reinforced composite (FRC) and metal wire were used for reinforcement. Reinforced bar-shaped specimens (65 mm long, 10 mm wide, 3.3 mm high) were fabricated (n = 10). The flexural strength at the proportional limit (FS-PL) and the elastic modulus were measured using a three-point bending test.All the denture base material specimens reinforced with FRC possessed a significantly higher FS-PL compared to those without reinforcement. The FS-PL of the polycarbonate specimens reinforced with metal wire was significantly higher than that without reinforcement, and there was no significant difference in the FS-PL between the polycarbonate specimens reinforced with FRC and those with metal wire. The order of the elastic modulus according to the denture base material, arranged in terms of statistical significance, was as follows: PMMA (3.46 ± 0.53 GPa) > polycarbonate (2.69 ± 0.48 GPa) > polyester (2.00 ± 0.39 GPa) > polyamide (1.14 ± 0.35 GPa). The order of the elastic modulus according to the reinforcement, arranged in terms of statistical significance, was as follows: metal wire (2.74 ± 0.96 GPa) > FRC (2.40 ± 0.89 GPa) > no reinforcement (1.82 ± 0.83 GPa).Continuous unidirectional glass fiber-reinforced composite (FRC) reinforcement had a satisfactory reinforcing effect for the injection-molded thermoplastic denture base resins.福岡歯科大学2017年

    Flexural strengths of reinforced denture base resins subjected to long-term water immersion

    No full text
    Objective This study evaluated the flexural strengths of reinforced denture base resins subjected to long-term water immersion. Materials and methods Acrylic denture base resin reinforced with metal wire or glass fiber-reinforced composite (FRC), and without reinforcement were tested. Bar-shaped specimens were fabricated. Half of the specimens were stored in 37 °C distilled water for 50 hours (h), the other half were stored in 37 °C distilled water for 180 days (d) before testing. Ten specimens were fabricated per group for each reinforcement/water immersion period combination. The ultimate flexural strength and flexural strength at the proportional limit of reinforced denture base resin were tested. Results The 180 d bulk specimen possessed significantly lower ultimate flexural strength compared with the 50 h bulk specimen (p  0.05). The 180 d bulk specimen had a significantly lower flexural strength at the proportional limit compared to the 50 h bulk specimen. The 180 d reinforced specimens of metal and FRC were not significantly different from each of the 50 h specimens. Conclusion The flexural strengths of a reinforced denture base resin did not change after long-term water immersion

    Association of physiological factors with grip and leg extension strength: tohoku medical megabank community-based cohort study

    No full text
    Abstract Background Upper and lower extremity muscle strength can be used to predict health outcomes. However, the difference between the relation of upper extremity muscle and of lower extremity muscle with physiological factors is unclear. This study aimed to evaluate the association between physiological data and muscle strength, measured using grip and leg extension strength, among Japanese adults. Methods We conducted a cross-sectional study of 2,861 men and 6,717 women aged ≥ 20 years living in Miyagi Prefecture, Japan. Grip strength was measured using a dynamometer. Leg extension strength was measured using a hydraulic isokinetic leg press machine. Anthropometry and physiological data, including blood pressure, calcaneal ultrasound bone status, pulmonary function, carotid echography, and blood information, were assessed. We used a general linear model adjusted for age, body composition, and smoking status to evaluate the association between muscle strength and physiological factors. Results Grip and leg extension strength were positively associated with bone area ratio, vital capacity, forced vital capacity, forced expiratory volume in one second, and estimated glomerular filtration rate, and negatively associated with waist circumference and percentage body fat mass in both the sexes. Diastolic blood pressure was positively associated with grip strength in both the sexes and leg extension strength in men, but not women. High-density lipoprotein cholesterol and red blood cell counts were positively associated with grip and leg extension strength in women, but not men. In both the sexes, pulse rate, total cholesterol, and uric acid were consistently associated with only leg extension strength, but not grip strength. In women, glycated hemoglobin demonstrated negative and positive associations with grip and leg extension strength, respectively. Conclusions Grip and leg extension strength demonstrated similar associations with anthropometry, pulmonary function, and estimated glomerular filtration rate, but the associations with the other factors were not always consistent
    corecore