34 research outputs found
Nociceptors: a phylogenetic view
The ability to react to environmental change is crucial for the survival of an organism and an essential prerequisite is the capacity to detect and respond to aversive stimuli. The importance of having an inbuilt “detect and protect” system is illustrated by the fact that most animals have dedicated sensory afferents which respond to noxious stimuli called nociceptors. Should injury occur there is often sensitization, whereby increased nociceptor sensitivity and/or plasticity of nociceptor-related neural circuits acts as a protection mechanism for the afflicted body part. Studying nociception and nociceptors in different model organisms has demonstrated that there are similarities from invertebrates right through to humans. The development of technology to genetically manipulate organisms, especially mice, has led to an understanding of some of the key molecular players in nociceptor function. This review will focus on what is known about nociceptors throughout the Animalia kingdom and what similarities exist across phyla; especially at the molecular level of ion channels
Precise and rapid costal cartilage graft sectioning using a novel device: clinical application.
IMPORTANCE The use of costal cartilage as a graft in facial reconstructive surgery requires sectioning the cartilage into a suitable shape. OBJECTIVE To evaluate the accuracy of a novel mechanical device for producing uniform slices of costal cartilage and to illustrate the use of the device during nasal surgery. DESIGN Basic and clinical study using 100 porcine ex vivo costal cartilage slices and 9 operative cases. METHODS This instrument departs from antecedent devices in that it uses compression to secure and stabilize the specimen during sectioning. A total of 75 porcine costal cartilage ribs were clamped with minimal compression just sufficient to secure and stabilize the specimen while cutting. Slices having a length of 4 cm and width of 1 cm were obtained using the cartilage cutter at 3 thicknesses: 1 mm (n = 25), 2 mm (n = 25), and 3 mm (n = 25). The procedure was repeated for the 2-mm thick samples; however, the ribs in this group (n = 25) were clamped using the maximum amount of compression attainable by the device. Thickness was measured using a digital micrometer. Case presentations illustrate the use of the device in secondary and reconstructive rhinoplasty surgery. RESULTS All specimens were highly uniform in thickness on visual inspection and appeared to be adequate for clinical application. Sectioning was completed in several seconds without complication. In the porcine specimens sectioned using minimal compression, the percentage difference in thickness for each individual sample averaged 18%, 10%, and 11% for the 1-mm-, 2-mm-, and 3-mm-thick slices, respectively. Within the specimens sectioned using maximum compression, the percentage difference in thickness for each individual sample averaged 35% for the 2-mm-thick slices. In the setting of nasal reconstructive surgery, slices having a thickness from 1 to 2 mm were found to be well suited for all necessary graft types. CONCLUSIONS AND RELEVANCE The simple mechanical device described produces costal cartilage graft slices with highly uniform thickness. Securing the rib by clamping during cutting reduces uniformity of the slices; however, the imperfections are minimal, and all sectioned grafts are adequate for clinical application. The device can be adjusted to produce slices of appropriate thickness for all nasal cartilage grafts. This device is valuable for reconstructive procedures owing to its ease of use, rapid operation, and reproducible results
Model to Estimate Threshold Mechanical Stability of Lower Lateral Cartilage.
ImportanceIn rhinoplasty, techniques used to alter the shape of the nasal tip often compromise the structural stability of the cartilage framework in the nose. Determining the minimum threshold level of cartilage stiffness required to maintain long-term structural stability is a critical aspect in performing these surgical maneuvers.ObjectiveTo quantify the minimum threshold mechanical stability (elastic modulus) of lower lateral cartilage (LLC) according to expert opinion.MethodsFive anatomically correct LLC phantoms were made from urethane via a 3-dimensional computer modeling and injection molding process. All 5 had identical geometry but varied in stiffness along the intermediate crural region (0.63-30.6 MPa).Design, setting, and participantsA focus group of experienced rhinoplasty surgeons (n = 33) was surveyed at a regional professional meeting on October 25, 2013. Each survey participant was presented the 5 phantoms in a random order and asked to arrange the phantoms in order of increasing stiffness based on their sense of touch. Then, they were asked to select a single phantom out of the set that they believed to have the minimum acceptable mechanical stability for LLC to maintain proper form and function.Main outcomes and measuresA binary logistic regression was performed to calculate the probability of mechanical acceptability as a function of the elastic modulus of the LLC based on survey data. A Hosmer-Lemeshow test was performed to measure the goodness of fit between the logistic regression and survey data. The minimum threshold mechanical stability for LLC was taken at a 50% acceptability rating.ResultsPhantom 4 was selected most frequently by the participants as having the minimum acceptable stiffness for LLC intermediate care. The minimum threshold mechanical stability for LLC was determined to be 3.65 MPa. The Hosmer-Lemeshow test revealed good fit between the logistic regression and survey data (χ23 = 0.92, P = .82).Conclusions and relevanceThis study presents a novel method of modeling anatomical structures and quantifying the mechanical properties of nasal cartilage. Quantifying these parameters is an important step in guiding surgical maneuvers performed in rhinoplasty.Level of evidence5
Recommended from our members
In-depth analysis of pH-dependent mechanisms of electromechanical reshaping of rabbit nasal septal cartilage.
OBJECTIVES/HYPOTHESIS: Electromechanical reshaping (EMR) involves reshaping cartilage by mechanical deformation and delivering electric current to the area around the bend axis, causing local stress relaxation and permanent shape change. The mechanism of EMR is currently unclear, although preliminary studies suggest that voltage and application time are directly related to the concentration and diffusion of acid-base products within the treated tissue with little heat generation. This study aims to characterize local tissue pH changes following EMR and to demonstrate that local tissue pH changes are correlated with tissue damage and shape change. STUDY DESIGN: Ex vivo animal study involving EMR of rabbit nasal septal cartilage and biochemical estimation of tissue pH changes. METHODS: The magnitude and diffusion of acid-base chemical products in control (0V, 2 minutes), shape change (4V, 4 minutes; 6V, 1, 2, 4 minutes; 8V, 1, 2 minutes), and tissue damage (8V, 4, 5 minutes; 10V, 4, 5 minutes) parameters following EMR are approximated by analyzing local pH changes after pH indicator application. RESULTS: There is a direct relationship between total charge transfer and extent of acid-base product diffusion (P <0.05). A pH transition zone is seen surrounding the bend apex above 8V, 2 minutes. Colorimetric analysis suggests that small local pH changes (10(-8) hydrogen ions) are at least partly implicated in clinically efficacious EMR. CONCLUSIONS: These results provide additional insight into the translational applications of EMR, particularly the relationship among pH changes, shape change, and tissue injury, and are integral in optimizing this promising technology for clinical use
Model to Estimate Threshold Mechanical Stability of Lower Lateral Cartilage
IMPORTANCE: In rhinoplasty, techniques used to alter the shape of the nasal tip often compromise the structural stability of the cartilage framework in the nose. Determining the minimum threshold level of cartilage stiffness required to maintain long-term structural stability is a critical aspect in performing these surgical maneuvers. OBJECTIVE: To quantify the minimum threshold mechanical stability (elastic modulus) of lower lateral cartilage (LLC) according to expert opinion. METHODS: Five anatomically correct LLC phantoms were made from urethane via a 3-dimensional computer modeling and injection molding process. All 5 had identical geometry but varied in stiffness along the intermediate crural region (0.63–30.6 MPa). DESIGN, SETTING, AND PARTICIPANTS: A focus group of experienced rhinoplasty surgeons (n = 33) was surveyed at a regional professional meeting on October 25, 2013. Each survey participant was presented the 5 phantoms in a random order and asked to arrange the phantoms in order of increasing stiffness based on their sense of touch. Then, they were asked to select a single phantom out of the set that they believed to have the minimum acceptable mechanical stability for LLC to maintain proper form and function. MAIN OUTCOMES AND MEASURES: A binary logistic regression was performed to calculate the probability of mechanical acceptability as a function of the elastic modulus of the LLC based on survey data. A Hosmer-Lemeshow test was performed to measure the goodness of fit between the logistic regression and survey data. The minimum threshold mechanical stability for LLC was taken at a 50% acceptability rating. RESULTS: Phantom 4 was selected most frequently by the participants as having the minimum acceptable stiffness for LLC intermediate care. The minimum threshold mechanical stability for LLC was determined to be 3.65 MPa. The Hosmer-Lemeshow test revealed good fit between the logistic regression and survey data ( [Formula: see text] , P = .82). CONCLUSIONS AND RELEVANCE: This study presents a novel method of modeling anatomical structures and quantifying the mechanical properties of nasal cartilage. Quantifying these parameters is an important step in guiding surgical maneuvers performed in rhinoplasty. LEVEL OF EVIDENCE: 5
Mechanical analysis of the effects of cephalic trim on lower lateral cartilage stability.
ObjectiveTo determine how mechanical stability changes in the lower lateral cartilage (LLC) after varying degrees of cephalic resection in a porcine cartilage nasal tip model.MethodsAlar cartilage was harvested from fresh porcine crania (n = 14) and sectioned to precisely emulate a human LLC in size and dimension. Flexural mechanical analysis was performed both before and after cephalic trims of 0 (control), 4, and 6 mm. Cantilever deformation tests were performed on the LLC models at 3 locations (4, 6, and 8 mm from the midline), and the integrated reaction force was measured. An equivalent elastic modulus of the crura was calculated assuming that the geometry of the LLC model approximated a modified single cantilever beam. A 3-dimensional finite element model was used to model the stress distribution of the prescribed loading conditions for each of the 3 types of LLC widths.ResultsA statistically significant decrease (P = .02) in the equivalent elastic modulus of the LLC model was noted at the most lateral point at 8 mm and only when 4 mm of the strut remained (P = .05). The finite element model revealed that the greatest internal stresses was at the tip of the nose when tissue was flexed 8 mm from the midline.ConclusionOur results provide the mechanical basis for suggested clinical guidelines stating that a residual strut of less than 6 mm can lead to suboptimal cosmetic results owing to poor structural support of the overlying skin soft-tissue envelope by an overly resected LLC
The rabbit costal cartilage reconstructive surgical model.
Rib grafts in facial plastic surgery are becoming more frequently used. Small animal models, although not ideal may be used to emulate costal cartilage-based procedures. A surgical characterization of this tissue will assist future research in the selection of appropriate costal segments, based on quantitative and qualitative properties. The objective of this study is to assess the surgical anatomy of the rabbit costal margin and evaluate costal cartilage for use in either in vivo or ex vivo studies and to examine reconstructive procedures. Detailed thoracic dissections of 21 New Zealand white rabbits were performed post-mortem. Costal cartilage of true, false, and floating ribs were harvested. The length, thickness, and width at proximal, medial, and distal locations of the cartilage, with perichondrium intact were measured. Further qualitative observation and digital images of curvature, flexibility, and segmental cross-sectional shape were recorded. The main outcome measure(s) is to characterize, describe, and assess the consistency of dimensions, location, and shape of costal cartilage. In this study, 12 to 13 ribs encase the thoracic cavity. Cartilage from true ribs has an average length, width, and depth of 23.75 ± 0.662, 3.02 ± 0.025, and 2.18 ± 0.018 mm, respectively. The cartilage from false ribs has an average length, width, and depth of 41.97 ± 1.48, 2.00 ± 0.07, 1.19 ± 0.03 mm, and that of floating ribs are 7.66 ± 0.29, 1.98 ± 0.04, and 0.96 ± 0.03 mm. Rib 8 is found to be the longest costal cartilage (49.10 ± 0.64 mm), with the widest and thickest at ribs 1 (3.91 ± 0.08 mm) and 6 (2.41 ± 0.11 mm), respectively. Cross-sectional segments reveal the distal cartilage to maintain an hourglass shape that broadens to become circular and eventually ovoid at the costochondral junction. The New Zealand white rabbit is a practical source of costal cartilage that is of sufficient size and reproducibility to use in surgical research where the long-term effects of operations, therapies, devices, and pharmacologic on cartilage can be studied in vivo
Recommended from our members
The rabbit costal cartilage reconstructive surgical model.
Rib grafts in facial plastic surgery are becoming more frequently used. Small animal models, although not ideal may be used to emulate costal cartilage-based procedures. A surgical characterization of this tissue will assist future research in the selection of appropriate costal segments, based on quantitative and qualitative properties. The objective of this study is to assess the surgical anatomy of the rabbit costal margin and evaluate costal cartilage for use in either in vivo or ex vivo studies and to examine reconstructive procedures. Detailed thoracic dissections of 21 New Zealand white rabbits were performed post-mortem. Costal cartilage of true, false, and floating ribs were harvested. The length, thickness, and width at proximal, medial, and distal locations of the cartilage, with perichondrium intact were measured. Further qualitative observation and digital images of curvature, flexibility, and segmental cross-sectional shape were recorded. The main outcome measure(s) is to characterize, describe, and assess the consistency of dimensions, location, and shape of costal cartilage. In this study, 12 to 13 ribs encase the thoracic cavity. Cartilage from true ribs has an average length, width, and depth of 23.75 ± 0.662, 3.02 ± 0.025, and 2.18 ± 0.018 mm, respectively. The cartilage from false ribs has an average length, width, and depth of 41.97 ± 1.48, 2.00 ± 0.07, 1.19 ± 0.03 mm, and that of floating ribs are 7.66 ± 0.29, 1.98 ± 0.04, and 0.96 ± 0.03 mm. Rib 8 is found to be the longest costal cartilage (49.10 ± 0.64 mm), with the widest and thickest at ribs 1 (3.91 ± 0.08 mm) and 6 (2.41 ± 0.11 mm), respectively. Cross-sectional segments reveal the distal cartilage to maintain an hourglass shape that broadens to become circular and eventually ovoid at the costochondral junction. The New Zealand white rabbit is a practical source of costal cartilage that is of sufficient size and reproducibility to use in surgical research where the long-term effects of operations, therapies, devices, and pharmacologic on cartilage can be studied in vivo