11 research outputs found

    Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995

    Get PDF
    AbstractObjectives: A total of 4756 cases of intraaortic balloon pump support have been recorded at the Massachusetts General Hospital since the first clinical insertion for cardiogenic shock in 1968. This report describes the patterns of intraaortic balloon use and associated outcomes over this time period.Methods: A retrospective record review was conducted.Results: Balloon use has increased to more than 300 cases a year at present. The practice of balloon placement for control of ischemia (2453 cases, 11.9% mortality) has become more frequent, whereas support for hemodynamic decompensation (congestive heart failure, hypotension, cardiogenic shock) has been relatively constant (1760 cases, 38.2% mortality). Mean patient age has increased from 54 to 66 years, and mortality has fallen from 41% to 20%. Sixty-five percent (3097/4756) of the total patient population receiving balloon support underwent cardiac surgery. Placement before the operation (2038 patients) was associated with a lower mortality (13.6%) than intraoperative (771 patients, 35.7% mortality) or postoperative use (276 patients, 35.9% mortality). Independent predictors of death with balloon pump support were insertion in the operating room or intensive care unit, transthoracic insertion, age, procedure other than angioplasty or coronary artery bypass, and insertion for cardiogenic shock. Independent predictors of death with intraoperative balloon insertion were age, mitral valve replacement, prolonged cardiopulmonary bypass, urgent or emergency operation, preoperative renal dysfunction, complex ventricular ectopy, right ventricular failure, and emergency reinstitution of cardiopulmonary bypass.Conclusions: Balloons are being used more frequently for control of ischemia in more patients who are elderly with lower mortality. An institutional bias toward preoperative use of the balloon pump appears to be associated with improved outcomes. (J Thorac Cardiovasc Surg 1997;113:758-69

    Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients.

    No full text
    OBJECTIVES: The aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV). BACKGROUND: Younger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR. METHODS: The LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested. RESULTS: In the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was \u3c2 \u3emm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction. CONCLUSIONS: TAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients

    Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Aortic Stenosis.

    No full text
    BACKGROUND: Transcatheter aortic valve replacement (TAVR) is now the standard of care for patients with symptomatic severe aortic stenosis who are extreme, high, or intermediate risk for surgical aortic valve replacement (SAVR). OBJECTIVES: The authors sought to evaluate TAVR in a prospective multicenter trial involving low-risk patients. METHODS: The Low Risk TAVR (Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis) trial was the first U.S. Food and Drug Administration-approved Investigational Device Exemption trial to enroll in the United States. This investigator-led trial was a prospective, multicenter, unblinded, comparison to historical controls from the Society of Thoracic Surgeons (STS) database. The primary endpoint was all-cause mortality at 30 days. RESULTS: The authors enrolled 200 low-risk patients with symptomatic severe aortic stenosis at 11 centers to undergo TAVR. The authors compared outcomes with an inverse probability weighting-adjusted control cohort of 719 patients who underwent SAVR at the same institutions using the STS database. At 30 days, there was zero all-cause mortality in the TAVR group versus 1.7% mortality in the SAVR group. There was zero in-hospital stroke rate in the TAVR group versus 0.6% stroke in the SAVR group. Permanent pacemaker implantation rates were similar between TAVR and SAVR (5.0% vs. 4.5%). The rates of new-onset atrial fibrillation (3.0%) and length of stay (2.0 ± 1.1 days) were low in the TAVR group. One patient (0.5%) in the TAVR group had \u3emild paravalvular leak at 30 days. Fourteen percent of TAVR patients had evidence of subclinical leaflet thrombosis at 30 days. CONCLUSIONS: TAVR is safe in low-risk patients with symptomatic severe aortic stenosis, with low procedural complication rates, short hospital length of stay, zero mortality, and zero disabling stroke at 30 days. Subclinical leaflet thrombosis was observed in a minority of TAVR patients at 30 days. (Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis [Low Risk TAVR; NCT02628899)

    Coronary Artery Disease Assessed by Computed Tomography-Based Leaman Score in Patients With Low-Risk Transcatheter Aortic Valve Implantation.

    No full text
    We aimed to evaluate the burden of coronary artery disease (CAD) using the computed tomography (CT) Leaman score in low-risk transcatheter aortic valve implantation (TAVI) patients. The extent of CAD in low-risk patients with aortic stenosis who are candidates for TAVI has not been accurately quantified. The CT Leaman score was developed to quantify coronary CT angiography (CCTA) atherosclerotic burden and has been validated to evaluate the extent of CAD. CT Leaman score \u3e5 has been associated with an increase in major adverse cardiac events over long-term follow-up. The study population included patients enrolled in the Low Risk TAVI trial who underwent CCTA before the procedure. For the CT Leaman score, we used 3 sets of weighting factors: (1) location of coronary plaques, (2) type of plaque, and (3) degree of stenosis. A total of 200 patients were enrolled in the Low Risk TAVI trial. Excluded were 31 patients who had no analyzable CCTA imaging. For the remaining 169 patients, the mean CT Leaman score was 6.27 ± 0.27, of whom 102 (60.4%) had CT Leaman score \u3e5. Nearly all analyzed patients (97%) had coronary plaques. Furthermore, 33 patients (19.5%) had potentially obstructive coronary plaques (\u3e50% stenosis by CCTA) in proximal segments. Most low-risk TAVI patients have significant CAD burden by CCTA. It should be a priority for future TAVI devices to guarantee unimpeded access to the coronary arteries for selective angiography and interventions

    TAVR in Low-Risk Patients: 1-Year Results From the LRT Trial.

    No full text
    OBJECTIVES: This study sought to evaluate clinical outcomes and transcatheter heart valve hemodynamics at 1 year after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: Early results from the LRT (Low Risk TAVR) trial demonstrated that TAVR is safe in patients with symptomatic severe aortic stenosis who are at low risk for surgical valve replacement. METHODS: The LRT trial was an investigator-initiated, prospective, multicenter study and was the first Food and Drug Administration-approved Investigational Device Exemption trial to evaluate feasibility of TAVR in low-risk patients. The primary endpoint was all-cause mortality at 30 days. Secondary endpoints included clinical outcomes and valve hemodynamics at 1 year. RESULTS: The LRT trial enrolled 200 low-risk patients with symptomatic severe AS to undergo TAVR at 11 centers. Mean age was 73.6 years and 61.5% were men. At 30 days, there was zero mortality, zero disabling stroke, and low permanent pacemaker implantation rate (5.0%). At 1-year follow-up, mortality was 3.0%, stroke rate was 2.1%, and permanent pacemaker implantation rate was 7.3%. Two (1.0%) subjects underwent surgical reintervention for endocarditis. Of the 14% of TAVR subjects who had evidence of hypoattenuated leaflet thickening at 30 days, there was no impact on valve hemodynamics at 1 year, but the stroke rate was numerically higher (3.8% vs. 1.9%; p = 0.53). CONCLUSIONS: TAVR in low-risk patients with symptomatic severe aortic stenosis appears to be safe at 1 year. Hypoattenuated leaflet thickening, observed in a minority of TAVR patients at 30 days, did not have an impact on valve hemodynamics in the longer term

    Hemodynamics and Subclinical Leaflet Thrombosis in Low-Risk Patients Undergoing Transcatheter Aortic Valve Replacement.

    No full text
    BACKGROUND: This analysis evaluated echocardiographic predictors of hypoattenuated leaflet thickening (HALT) in low-risk patients undergoing transcatheter aortic valve replacement and assessed 1-year clinical and hemodynamic consequences. HALT by computed tomography may be associated with early valve degeneration and increased neurological events. METHODS: Echocardiograms were performed at baseline, discharge, 30 days, and 1 year post-procedure. Four-dimensional contrast-enhanced computed tomography assessed HALT at 30 days. Independent core laboratories analyzed images. Doppler hemodynamic parameters were tested in a univariable regression model to identify HALT predictors. One-year clinical and hemodynamic outcomes were compared between HALT (+) and (-) patients. RESULTS: Analysis included 170 patients with Sapien 3 valves and diagnostic 30-day computed tomographies, of whom 27 (16%) had HALT. Baseline characteristics were similar between groups. After transcatheter aortic valve replacement, aortic flow was nonsignificantly reduced in patients who developed HALT. Regression analysis did not show significant association between baseline or discharge valve hemodynamics and development of HALT at 30 days. Patients with HALT had smaller aortic valve areas (1.4±0.4 versus 1.7±0.5 cm CONCLUSIONS: There were no early hemodynamic predictors of HALT. At 30 days, patients with HALT had worse valve hemodynamics than those without HALT, but hemodynamic and clinical outcomes at 1 year were similar. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628899

    Anatomical characteristics associated with hypoattenuated leaflet thickening in low-risk patients undergoing transcatheter aortic valve replacement.

    No full text
    BACKGROUND/PURPOSE: This sub-analysis of the prospective Low Risk TAVR (LRT) trial determined anatomical characteristics associated with hypoattenuated leaflet thickening (HALT), which may contribute to early transcatheter heart valve (THV) degeneration. METHODS/MATERIALS: The LRT trial enrolled 200 low-risk patients between February 2016 and February 2018. All subjects underwent baseline and 30-day CT studies, analyzed by an independent core laboratory. Additional measurements, namely THV expansion, eccentricity, depth, and commissural alignment, were made by consensus of three independent readers. HALT was observed only in the Sapien 3 THV, so Evolut valves were excluded from this analysis. RESULTS: In the LRT trial, 177 subjects received Sapien 3 THVs, of whom 167 (94.3%) had interpretable 30-day CTs and were eligible for this analysis. Twenty-six subjects had HALT (15.6%). Baseline characteristics were similar between groups. There was no difference in THV size implanted and baseline aortic-root geometry between groups. In patients who developed HALT, THV implantation depth was shallower than in patients who did not develop HALT (2.6 ± 1.1 mm HALT versus 3.3 ± 1.8 mm no-HALT, p = 0.03). There were more patients in the HALT group with commissural malalignment (40% vs. 28%; p = 0.25), but this did not reach statistical significance. In a univariable regression model, no predetermined variables were shown to independently predict the development of HALT. CONCLUSIONS: This study did not find anatomical or THV implantation characteristics that predicted the development of HALT at 30 days. This study cannot exclude subtle effects or interaction between factors because of the small number of events. SUMMARY: This sub-analysis of the prospective Low Risk TAVR trial found that hypoattenuated leaflet thickening (HALT) was associated with shallower transcatheter heart valve implantation. No predictors of HALT were found in a univariable regression analysis
    corecore