21 research outputs found

    PillCamColon2 after incomplete colonoscopy - a prospective multicenter study

    No full text
    Aim: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield. Methods: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours. Results: Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda. Conclusion: Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved

    Symptoms and clinical course of EHEC O104 infection in hospitalized patients: a prospective single center study.

    Get PDF
    OBJECTIVES: Shiga-toxin producing O157:H7 Entero Haemorrhagic E. coli (STEC/EHEC) is one of the most common causes of Haemolytic Uraemic Syndrome (HUS) related to infectious haemorrhagic colitis. Nearly all recommendations on clinical management of EHEC infections refer to this strain. The 2011 outbreak in Northern Europe was the first to be caused by the serotype O104:H4. This EHEC strain was found to carry genetic features of Entero Aggregative E. coli (EAEC) and extended spectrum β lactamase (ESBL). We report symptoms and complications in patients at one of the most affected centres of the 2011 EHEC O104 outbreak in Northern Germany. METHODS: The courses of patients admitted to our hospital due to bloody diarrhoea with suspected EHEC O104 infection were recorded prospectively. These data include the patients' histories, clinical findings, and complications. RESULTS: EHEC O104 infection was confirmed in 61 patients (female = 37; mean age: 44±2 years). The frequency of HUS was 59% (36/61) in our cohort. An enteric colonisation with co-pathogens was found in 57%. Thirty-one (51%) patients were treated with plasma-separation/plasmapheresis, 16 (26%) with haemodialysis, and 7 (11%) with Eculizumab. Patients receiving antibiotic treatment (n = 37; 61%) experienced no apparent change in their clinical course. Twenty-six (43%) patients suffered from neurological symptoms. One 83-year-old patient died due to comorbidities after HUS was successfully treated. CONCLUSIONS: EHEC O104:H4 infections differ markedly from earlier reports on O157:H7 induced enterocolitis in regard to epidemiology, symptomatology, and frequency of complications. We recommend a standard of practice for clinical monitoring and support the renaming of EHEC O104:H4 syndrome as "EAHEC disease"

    Reduced medication dependency and improved symptoms and quality of life 12 months after enteryx implantation for gastroesophageal reflux.

    No full text
    BACKGROUND: The need is well recognized for additional data on endoluminal therapies for gastroesophageal reflux disease (GERD). This prospective multicenter clinical trial was designed to assess safety and effectiveness of Enteryx, a nonresorbable copolymer implanted into the lower esophagus, in reducing usage of proton pump inhibitors (PPIs) and improving reflux symptoms and quality of life. METHODS: Enteryx implantation was performed under fluoroscopic visualization without general anesthesia in 93 patients with symptomatic GERD responsive to and relapsing upon cessation of PPI therapy. Subjective and objective data were collected up to 12 months postprocedure. The criterion for treatment success was reduction in PPI dosage of > or =50%. RESULTS: At 12 months, treatment success was attained in 86% (confidence interval, 77%-93%) of 74 evaluable patients and elimination of PPI therapy in 65% (confidence interval, 53%-76%). The treatment success rate by intent-to-treat analysis was 69% (confidence interval, 58%-78%). Reflux-related heartburn (P < 0.0001), regurgitation symptoms (P = 0.0005), and physical (P < 0.0001) and mental quality of life (P = 0.0012) scores improved. The most frequent complications were chest pain (77%), dysphagia/odynophagia (27%), and sensation of fever (26%). CONCLUSIONS: Enteryx implantation provides an effective and safe alternative for management of gastroesophageal reflux, reducing medication dependency and symptoms and enhancing quality of life.Clinical TrialJournal ArticleMulticenter Studyinfo:eu-repo/semantics/publishe

    Capsule endoscopy versus colonoscopy for the detection of polyps and cancer.

    No full text
    BACKGROUND: An ingestible capsule consisting of an endoscope equipped with a video camera at both ends was designed to explore the colon. This study compared capsule endoscopy with optical colonoscopy for the detection of colorectal polyps and cancer. METHODS: We performed a prospective, multicenter study comparing capsule endoscopy with optical colonoscopy (the standard for comparison) in a cohort of patients with known or suspected colonic disease for the detection of colorectal polyps or cancer. Patients underwent an adapted colon preparation, and colon cleanliness was graded from poor to excellent. We computed the sensitivity and specificity of capsule endoscopy for polyps, advanced adenoma, and cancer. RESULTS: A total of 328 patients (mean age, 58.6 years) were included in the study. The capsule was excreted within 10 hours after ingestion and before the end of the lifetime of the battery in 92.8% of the patients. The sensitivity and specificity of capsule endoscopy for detecting polyps that were 6 mm in size or bigger were 64% (95% confidence interval [CI], 59 to 72) and 84% (95% CI, 81 to 87), respectively, and for detecting advanced adenoma, the sensitivity and specificity were 73% (95% CI, 61 to 83) and 79% (95% CI, 77 to 81), respectively. Of 19 cancers detected by colonoscopy, 14 were detected by capsule endoscopy (sensitivity, 74%; 95% CI, 52 to 88). For all lesions, the sensitivity of capsule endoscopy was higher in patients with good or excellent colon cleanliness than in those with fair or poor colon cleanliness. Mild-to-moderate adverse events were reported in 26 patients (7.9%) and were mostly related to the colon preparation. CONCLUSIONS: The use of capsule endoscopy of the colon allows visualization of the colonic mucosa in most patients, but its sensitivity for detecting colonic lesions is low as compared with the use of optical colonoscopy. (ClinicalTrials.gov number, NCT00604162.)Clinical TrialComparative StudyJournal ArticleMulticenter StudyResearch Support, Non-U.S. Gov'tinfo:eu-repo/semantics/publishe

    Kolonkapselendoskopie: Leitlinie der Europäischen Gesellschaft für Gastrointestinale Endoskopie

    No full text
    PillCam colon capsule endoscopy (CCE) is an innovative noninvasive, and painless ingestible capsule technique that allows exploration of the colon without the need for sedation and gas insufflation. Although it is already available in European and other countries, the clinical indications for CCE as well as the reporting and work-up of detected findings have not yet been standardized. The aim of this evidence-based and consensus-based guideline, commissioned by the European Society of Gastrointestinal Endoscopy (ESGE) is to furnish healthcare providers with a comprehensive framework for potential implementation of this technique in a clinical setting. © Georg Thieme Verlag KG stuttgart .New York.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore