    Development of future compact and eco-friendly HVDC gas-insulated systems: shape optimization of a DC spacer model and novel materials investigation

    Get PDF
    esting and validating the electrical insulation performance of full-size compact high-voltage direct current (HVDC) gas-insulated systems, gas-insulated transmission lines (GIL) and gas-insulated switchgears (GIS) is very costly and take long time. Therefore, a reduced scale system was designed and constructed to study thoroughly the spacer’s performance when subjected to higher electric fields under HVDC with different shapes, made of new advanced materials, and housed in new SF6-free gas environment. Since the stationary DC electric field distribution along the spacer is controlled by spacer material conductivity and strongly depends upon its shape, this, the first part of two articles, proposes in a first step based on electric field calculations with COMSOL Multiphysics software, an optimized shape of a spacer model using a standard high-voltage alternating current (HVAC) alumina-filled epoxy material. Then, two novel types of materials were introduced and investigated: (i) modified filled epoxy material with a lower temperature-dependent conductivity than that of the standard HVAC material, which is interpreted by a lower thermal activation energy; and (ii) nonlinear resistive field grading material with a low nonlinearity coefficient, with and without the presence of a temperature gradient which occurs under operating service load. The numerical results show that, despite that the DC optimized profile of the spacer made of standard HVAC, alumina-filled epoxy is very effective in relaxing the electric field magnitudes along the spacer under uniform temperature—its distribution is significantly affected by the presence of a high temperature gradient causing the maximum electric field shifts along the spacer surface towards the earthed flange. Under this condition, the modified filled epoxy material with a weaker temperature-dependent conductivity results in a significant reduction of the electric field enhancement, representing thus a relevant key solution for HVDC GIL/GIS applications. Nonlinear resistive field grading material is also effective but seems unnecessary. The optimized DC spacer models are being fabricated for tests verification with C4-Perfluoronitrile (C4-PFN, 3MTM NovecTM 4710)/CO2 and Trifluoroiodomethane (CF3I)/CO2 gas mixtures in the reduced scale gas-insulated test prototype

    A review on real-size epoxy cast resin insulators for compact high voltage direct current gas insulated switchgears (GIS) and gas insulated transmission lines (GIL)-current achievements and envisaged research and development

    Get PDF
    Due to the ever-increasing demand for electricity in the one hand and the environmental constraints to use clean energy on the other hand, the global production of energy from remote renewable sources, particularly from large hydropower plants and offshore wind farms and their connection to the grid are expected to grow significantly in the future. Consequently, the demand to carry this electric power by high voltage direct current (HVDC) technology will increase too. The most suitable HVDC power transmission technology to deliver large amounts of power, exceeding a capacity of 5 GW per bipolar system over long distances with lower losses is by using compact HVDC gas insulated transmission lines (DC GIL) and gas insulated switchgears (DC GIS) with rated voltage (maximum continuous operating voltage) of ±550 kV and 5000 A which are presently under development worldwide. Among the critical challenges for the development of these HVDC gas insulated systems, there are the epoxy cast resin insulators that are used to separate gas compartments also called spacers. Indeed, thorough research studies have been and still being carried out to well understand and clarify the electrical insulation characteristics of HVDC spacers using mainly cylindrical samples and small insulator models, where useful results have been obtained and proposed for implementation in real compact gas insulated systems. However, few practical investigations have been undertaken on real size spacers (product scale) to verify such research outcomes and validate the reliability of the spacers to collect experiences or for commercial use. This paper reviews the current achievements of real size HVDC spacers development. It describes the basic electric field calculation and spacers design, the verification of the insulation performance and validation testing. It gives today’s commercially available compact HVDC GIS/GIL and finally it presents the envisaged future research and developmen

    Modelling of a 400-kV MSCDN reactor for computation of voltage and field distributions during switching transients

    Get PDF
    In this paper, a model for the reactor of a 400-kV mechanically switched capacitor with damping network (MSCDN) based on an equivalent circuit representation is developed. The model is based on sub-dividing the physical reactor into sections which are sufficiently small to be represented by a lumpedparameter equivalent circuit. The circuit parameters are obtained for each section using analytical formulae based on the physical configuration of the reactor, the winding layout, and the insulation material. The model is then simulated in the ATP/EMTP program for the evaluation of transient voltage and field distributions along of the reactor. This helps in identifying possible failure scenarios which will allow designing measures to mitigate failures effectively during transients arising from switching operations. Further analysis of the results has revealed that there are substantial dielectric stresses imposed on the winding insulation that can be attributed to a combination of three factors. First, the surge arrester operation during the MSCDN energization, which causes steep voltage change at the reactor terminal. Second, the non-uniform voltage distribution, resulting in high stresses across the top inter-turn windings. Third, the rapid rate-of-change of voltage in the assumed worst-case reactor winding location. This is accompanied by a high dielectric (displacement) current through the inter-turn winding insulation. The results of this paper indicate that a synergistic effect of high electric field and high dielectric current occurring at worst energization, followed by the thermal effects of steady state operation may contribute to the failure of air-core reactors used on the 400-kV MSCDN

    Is the dry-band characteristic a function of pollution and insulator design?

    Get PDF
    This paper assesses the dry-band formation and location during artificial pollution tests performed on a 4-shed 11kV insulator with conventional and textured surface designs in a clean-fog chamber and with the application of a voltage ramp-shape source. The different designs present the same overall geometrical dimensions, but the textured ones are characterized by the application of a patented insulator surface design. Three pollution levels, extremely high, high and moderate, were considered. A newly developed MATLAB procedure is able to automatically recognize the perimeter of the insulator, the trunk and shed areas on infra-red recordings. In addition, using the vertical axis identification, all trunks are subdivided into zones and into left and right areas, significantly increasing the capability of abnormalities detection. Any temperature increase within these areas enables to detect the appearance and the extension of dry bands. The results of the analysis of the statistical location and extension development over time of the dry bands during these set of comparative tests show a clear distinction between designs and pollution levels. These results may offer interesting design guidelines for dry-band control

    275 kV cable discharge field measurement and analysis of SVLs chain failure using ATP

    Get PDF
    Results of field measurement of trapped charges on a 275 kV cable will be presented. The instrumentation and calibration method used in the measurement will be discussed. It will be shown that if the cable is not force-discharged by means of earth switches, the trapped charges will decay very slowly. The atmospheric parameters such as humidity and temperature affect the discharge time, which also depends on how much of the circuit is exposed to open air. The measurement results are used in EMTP-ATP simulation to confirm that trapped charges may be sufficient to cause sheath voltage limiters (SVL) of the cable to fail. The number of SVL breakdown depends on the mode of SVL failure, i.e. whether it attains low impedance (short circuit) or open circuit when the energy absorbed exceeds the rating

    Inhibition effect of solid products and DC breakdown characteristics of the HFO1234Ze(E)-N2-O2 ternary gas mixture

    Get PDF
    HFO1234ze(E) is an environmentally friendly SF6 substitute gas with prominent application potential. To suppress the generation of the HFO1234ze(E) solid decomposition products, which may cause great hazards to the gas–solid insulation strength, a gas mixing scheme screening method based on the reactive force field (ReaxFF) molecular dynamics (MD) simulation was innovatively proposed. The simulation results show that the inhibitory effect of O2 on the formation of HFO1234ze(E) solid products is better than those of CO2 and CF4. Further study shows that when O2 accounts for 3.33% of the gas mixture, the solid precipitate content is reduced by 48%. The experimental study shows that an O2 content of 3.33% can inhibit the generation of solid products by more than 50%. Besides, compared with HFO1234ze(E)-N2, the DC breakdown voltage of HFO1234ze(E)-N2-O2 is slightly increased, and the breakdown voltage dispersion degree and continuous breakdown voltage drop rate are decreased. This work gives a feasible solution for the suppression of HFO1234ze(E) solid decomposition products and provides an efficient method for solving similar problems of environmentally friendly insulating gas in C/F/O/N systems

    Partial discharge measurements in a high voltage gas insulated transmission line insulated with CO2

    Get PDF
    This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results can also help in understanding the properties of new alternative gas mixtures which can be utilised with a ratio of up to and over 95% CO2. The experiments undertaken involved filling a gas insulated line demonstrator with 3 bars of CO2 and applying voltages up to 242 kV in both clean conditions and particle-contaminated enclosure conditions. The results demonstrate that CO2 can be used to insulate gas equipment without breakdown at high voltage, however, a higher gas-filling pressure may be needed to reduce the partial discharge found in the tests presented in this paper. Another aspect of the work showed that partial discharge (PD) measurements from internal ultra-high frequency (UHF) sensors compared with a direct measurement from a capacitive divider both clearly showed the effect of contaminating particles in CO2. However, the PD divider measurements also showed considerable external PD on the outside of the gas compartment, leading to the conclusion that UHF sensors are still regarded as having the highest sensitivity and noise immunity for gas insulated switchgear (GIS) or gas insulated transmission line (GIL) systems including when the equipment is insulated with CO2

    Lightning strike damage resistance of carbon‐fiber composites with nanocarbon‐modified epoxy matrices

    Get PDF
    Carbon‐fiber reinforced polymer (CFRP) composites are replacing metal alloys in aerospace structures, but they can be vulnerable to lightning strike damage if not adequately protected due to the poor electrical conductivity of the polymeric matrix. In the present work, to improve the conductivity of the CFRP, two electrically conductive epoxy formulations were developed via the addition of 0.5 wt% of graphene nanoplatelets (GNPs) and a hybrid of 0.5 wt% of GNPs/carbon nanotubes (CNTs) at an 8:2 mass ratio. Unidirectional CFRP laminates were manufactured using resin‐infusion under flexible tooling (RIFT) and wet lay‐up (WL) processes, and subjected to simulated lightning strike tests. The electrical performance of the RIFT plates was far superior to that of the WL plates, independent of matrix modification, due to their greater carbon‐fiber volume fraction. The GNP‐modified panel made using RIFT demonstrated an electrical conductivity value of 8 S/cm. After the lightning strike test, the CFRP panel remains largely unaffected as no perforation occurs. Damage is limited to matrix degradation within the top ply at the point of impact and localized charring of the surface. The GNP‐modified panel showed a comparable level of resistance against lightning damage with the existing copper mesh technology, offering at the same time a 20% reduction in the structural weight. This indicates a feasible route to improve the lightning strike damage resistance of carbon‐fiber composites without the addition of extra weight, hence reducing fuel consumption but not safety

    Countdown to 2030 : tracking progress towards universal coverage for reproductive, maternal, newborn, and child health

    Get PDF
    Building upon the successes of Countdown to 2015, Countdown to 2030 aims to support the monitoring and measurement of women's, children's, and adolescents' health in the 81 countries that account for 95% of maternal and 90% of all child deaths worldwide. To achieve the Sustainable Development Goals by 2030, the rate of decline in prevalence of maternal and child mortality, stillbirths, and stunting among children younger than 5 years of age needs to accelerate considerably compared with progress since 2000. Such accelerations are only possible with a rapid scale-up of effective interventions to all population groups within countries (particularly in countries with the highest mortality and in those affected by conflict), supported by improvements in underlying socioeconomic conditions, including women's empowerment. Three main conclusions emerge from our analysis of intervention coverage, equity, and drivers of reproductive, maternal, newborn, and child health (RMNCH) in the 81 Countdown countries. First, even though strong progress was made in the coverage of many essential RMNCH interventions during the past decade, many countries are still a long way from universal coverage for most essential interventions. Furthermore, a growing body of evidence suggests that available services in many countries are of poor quality, limiting the potential effect on RMNCH outcomes. Second, within-country inequalities in intervention coverage are reducing in most countries (and are now almost non-existent in a few countries), but the pace is too slow. Third, health-sector (eg, weak country health systems) and non-health-sector drivers (eg, conflict settings) are major impediments to delivering high-quality services to all populations. Although more data for RMNCH interventions are available now, major data gaps still preclude the use of evidence to drive decision making and accountability. Countdown to 2030 is investing in improvements in measurement in several areas, such as quality of care and effective coverage, nutrition programmes, adolescent health, early childhood development, and evidence for conflict settings, and is prioritising its regional networks to enhance local analytic capacity and evidence for RMNCH

    Ecology and Transmission of Buruli Ulcer Disease: A Systematic Review

    Get PDF
    Buruli ulcer is a neglected emerging disease that has recently been reported in some countries as the second most frequent mycobacterial disease in humans after tuberculosis. Cases have been reported from at least 32 countries in Africa (mainly west), Australia, Southeast Asia, China, Central and South America, and the Western Pacific. Large lesions often result in scarring, contractual deformities, amputations, and disabilities, and in Africa, most cases of the disease occur in children between the ages of 4–15 years. This environmental mycobacterium, Mycobacterium ulcerans, is found in communities associated with rivers, swamps, wetlands, and human-linked changes in the aquatic environment, particularly those created as a result of environmental disturbance such as deforestation, dam construction, and agriculture. Buruli ulcer disease is often referred to as the “mysterious disease” because the mode of transmission remains unclear, although several hypotheses have been proposed. The above review reveals that various routes of transmission may occur, varying amongst epidemiological setting and geographic region, and that there may be some role for living agents as reservoirs and as vectors of M. ulcerans, in particular aquatic insects, adult mosquitoes or other biting arthropods. We discuss traditional and non-traditional methods for indicting the roles of living agents as biologically significant reservoirs and/or vectors of pathogens, and suggest an intellectual framework for establishing criteria for transmission. The application of these criteria to the transmission of M. ulcerans presents a significant challenge
    corecore