11,159 research outputs found

    The uniting of Europe and the foundation of EU studies: revisiting the neofunctionalism of Ernst B. Haas

    Get PDF
    This article suggests that the neofunctionalist theoretical legacy left by Ernst B. Haas is somewhat richer and more prescient than many contemporary discussants allow. The article develops an argument for routine and detailed re-reading of the corpus of neofunctionalist work (and that of Haas in particular), not only to disabuse contemporary students and scholars of the normally static and stylized reading that discussion of the theory provokes, but also to suggest that the conceptual repertoire of neofunctionalism is able to speak directly to current EU studies and comparative regionalism. Neofunctionalism is situated in its social scientific context before the theory's supposed erroneous reliance on the concept of 'spillover' is discussed critically. A case is then made for viewing Haas's neofunctionalism as a dynamic theory that not only corresponded to established social scientific norms, but did so in ways that were consistent with disciplinary openness and pluralism

    Kondo temperature of magnetic impurities at surfaces

    Full text link
    Based on the experimental observation, that only the close vicinity of a magnetic impurity at metal surfaces determines its Kondo behaviour, we introduce a simple model which explains the Kondo temperatures observed for cobalt adatoms at the (111) and (100) surfaces of Cu, Ag, and Au. Excellent agreement between the model and scanning tunneling spectroscopy (STS) experiments is demonstrated. The Kondo temperature is shown to depend on the occupation of the d-level determined by the hybridization between adatom and substrate with a minimum around single occupancy.Comment: 4 pages, 2 figure

    Scoping review of clinical practice guidelines on the management of benign liver tumours

    Get PDF
    OBJECTIVE: Benign liver tumours (BLT) are increasingly diagnosed as incidentalomas. Clinical implications and management vary across and within the different types of BLT. High-quality clinical practice guidelines are needed, because of the many nuances in tumour types, diagnostic modalities, and conservative and invasive management strategies. Yet, available observational evidence is subject to interpretation which may lead to practice variation. Therefore, we aimed to systematically search for available clinical practice guidelines on BLT, to critically appraise them, and to compare management recommendations. DESIGN: A scoping review was performed within MEDLINE, EMBASE, and Web of Science. All BLT guidelines published in peer-reviewed, and English language journals were eligible for inclusion. Clinical practice guidelines on BLT were analysed, compared, and critically appraised using the Appraisal of Guidelines, Research and Evaluation (AGREE II) checklist regarding hepatic haemangioma, focal nodular hyperplasia (FNH), and hepatocellular adenoma (HCA). Preferred Reporting Items for Systematic Reviews and Meta-Analyses recommendations (PRISMA) for scoping reviews were adhered to. RESULTS: The literature search yielded unique 367 papers, 348 were excluded after screening of title/abstract, and 16 after full-text screening. Three guidelines were included: the American College of Gastroenterology (ACG; 2014), Brazilian Society of Hepatology (SBH; 2015), and European Association for the Study of the Liver (EASL; 2016). There was no uniformity in the assessment methods for grading and gravity of recommendations between guidelines. Among observed differences were: (1) indications for biopsy in all three tumours; (2) advices on contraceptive pills and follow-up in FNH and HCA; (3) use of an individualised approach to HCA; (4) absence of recommendations for treatment of HCA in men; and (5) approaches to HCA subtype identification on magnetic resonance imaging. CONCLUSION: Recognising differences in recommendations can assist in harmonisation of practice standards and identify unmet needs in research. This may ultimately contribute to improved global patient care

    Interplay of size and Landau quantizations in the de Haas-van Alphen oscillations of metallic nanowires

    Get PDF
    We examine the interplay between size quantization and Landau quantization in the De Haas-Van Alphen oscillations of clean, metallic nanowires in a longitudinal magnetic field for `hard' boundary conditions, i.e. those of an infinite round well, as opposed to the `soft' parabolically confined boundary conditions previously treated in Alexandrov and Kabanov (Phys. Rev. Lett. {\bf 95}, 076601 (2005) (AK)). We find that there exist {\em two} fundamental frequencies as opposed to the one found in bulk systems and the three frequencies found by AK with soft boundary counditions. In addition, we find that the additional `magic resonances' of AK may be also observed in the infinite well case, though they are now damped. We also compare the numerically generated energy spectrum of the infinite well potential with that of our analytic approximation, and compare calculations of the oscillatory portions of the thermodynamic quantities for both models.Comment: Title changed, paper streamlined on suggestion of referrees, typos corrected, numerical error in figs 2 and 3 corrected and final result simplified -- two not three frequencies (as in the previous version) are observed. Abstract altered accordingly. Submitted to Physical Review

    Doppler Ultrasound of Vascular Complications After Pediatric Liver Transplantation:Incidence, Time of Detection, and Positive Predictive Value

    Get PDF
    Purpose Doppler ultrasound (DUS) is widely used to detect vascular complications after pediatric liver transplantation (LT). This study aimed to assess the moment of first detection of vascular complications with DUS, and to determine the positive predictive value (PPV) of DUS. Materials and Methods Patients aged 0–18 years who underwent LT between 2015 and 2019 were retrospectively included. 92 LTs in 83 patients were included (median age: 3.9 years, interquartile range: 0.7–10.5). Patients underwent perioperative (intra-operative and immediately postoperative) and daily DUS surveillance during the first postoperative week, and at 1, 3, and 12 months. Vascular complications were categorized for the hepatic artery, portal vein, and hepatic veins. DUS findings were compared to surgical or radiological findings during the 1-year follow-up. Results 52 vascular complications were diagnosed by DUS in 35/92 LTs (38%). 15 out of 52 (28.8%) were diagnosed perioperatively, 29/52 (55.8%) were diagnosed on postoperative days 1–7, and 8/52 (15.4%) after day 7. The PPV for all vascular complications diagnosed with DUS was 92.3%. During the 1-year follow-up, 18/19 (94.7%) hepatic artery complications, 19/26 (73.1%) portal vein complications, and 7/7 (100%) hepatic vein complications were diagnosed perioperatively or during the first week. Conclusion The majority of vascular complications during the first year after pediatric LT were diagnosed by DUS perioperatively or during the first week, with a high PPV. Our findings provide important information regarding when to expect different types of vascular complications on DUS, which might improve DUS post-LT surveillance protocols

    The diagnostic accuracy of CT and MRI for the detection of lymph node metastases in gallbladder cancer:A systematic review and meta-analysis

    Get PDF
    BACKGROUND: Lymph node metastases (LNM) are an ominous prognostic factor in gallbladder cancer (GBC) and, when present, should preclude surgery. However, uncertainty remains regarding the optimal imaging modality for pre-operative detection of LNM and international guidelines vary in their recommendations. The purpose of this study was to systematically review the diagnostic accuracy of computed tomography (CT) versus magnetic resonance imaging (MRI) in the detection of LNM of GBC. METHODS: A literature search of studies published until November 2017 concerning the diagnostic accuracy of CT or MRI regarding the detection of LNM in GBC was performed. Data extraction and risk of bias assessment was performed independently by two reviewers. The sensitivity of CT and MRI in the detection of LNM was reviewed. Additionally, estimated summary sensitivity, specificity and diagnostic accuracy of MRI were calculated in a patient based meta-analysis. RESULTS: Nine studies including 292 patients were included for narrative synthesis and 5 studies including 158 patients were selected for meta-analysis. Sensitivity of CT ranged from 0.25 to 0.93. Estimated summary diagnostic accuracy parameters of MRI were as follows: sensitivity 0.75 (95% CI 0.6 - 0.85), specificity 0.83 (95% CI 0.74 - 0.90), LR + 4.52 (95% CI 2.55-6.48) and LR- 0.3 (95% CI 0.15 - 0.45). Small (<10 mm) LNM were most frequently undetected on pre-operative imaging. Due to a lack of data, no subgroup analysis comparing the diagnostic accuracy of CT versus MRI could be performed. CONCLUSION: The value of current imaging strategies for the pre-operative assessment of nodal status in GBC remains unclear, especially regarding the detection of small LNM. Additional research is warranted in order to establish uniformity in international guidelines, improve pre-operative nodal staging and to prevent futile surgery

    Behavior and complications of hepatocellular adenoma during pregnancy and puerperium:a retrospective study and systematic review

    Get PDF
    BACKGROUND: Hepatocellular adenomas (HCA) are benign liver tumors at risk of hemorrhage. The influence of pregnancy on HCA growth and potential bleeding remains unclear. This study investigates HCA-associated behavior and bleeding complications during or shortly after pregnancy. METHODS: (I) Single center retrospective cohort study of HCA during and after pregnancy (II) Systematic literature review. RESULTS: The retrospective study included 11 patients, of which 4 with HCA ≥5 cm. In only two patients HCA showed growth during pregnancy. In this local cohort, no HCA-related hemorrhages occurred during median follow-up of 34 months (interquartile range 19-58 months). The systematic review yielded 33 studies, totaling 90 patients with 99 pregnancies. Of 73 pregnancies without prior HCA-related intervention, 39 HCA remained stable (53.4%), 11 regressed (15.1%), and 23 (31.5%) progressed. Fifteen HCA-related hemorrhages occurred in HCA measuring 6.5-17.0 cm. Eight patients experienced bleeding during pregnancy, two during labor and five postpartum. CONCLUSION: Although hemorrhage of HCA during or shortly after pregnancy is rare and only reported in HCA ≥6.5 cm, it can be fatal. Pregnancy in women with HCA, regardless of size, warrant a close surveillance strategy. Observational studies on behavior and management of HCA ≥5 cm during and immediately after pregnancy are needed

    Assessment of hepatic artery anatomy in pediatric liver transplant recipients:MR angiography versus CT angiography

    Get PDF
    During LT screening, children undergo CTA to determine hepatic artery anatomy. However, CTA imparts radiation, unlike MRA. The aim was to compare MRA to CTA in assessing hepatic artery anatomy in pediatric LT recipients. Twenty-one children (median age 8.9 years) who underwent both CTA and fl3D-ce MRA before LT were retrospectively included. Interreader variability between 2 radiologists, image quality, movement artifacts, and confidence scores, were used to compare MRA to CTA. Subgroup analyses for ages <6 years and ≥6 years were performed. Interreader variability for MRA and CTA in children <6 years was comparable (k = 0.839 and k = 0.757, respectively), while in children ≥6 years CTA was superior to MRA (k 1.000 and k 0.000, respectively). Overall image quality and confidence scores of CTA were significantly higher compared to MRA at all ages (2.8/3 vs. 2.3/3, p = .001; and 2.9/3 vs. 2.5/3, p = .003, respectively). Movement artifacts were significantly lower in CTA compared to MRA in children ≥6 years (1.0/3 vs. 1.7/3, p = .010, respectively). CTA is preferred over fl3D-ce MRA for the preoperative assessment of hepatic artery anatomy in children receiving LT, both at ages <6 years and ≥6 years

    Doppler-ultrasound reference values after pediatric liver transplantation:a consecutive cohort study

    Get PDF
    OBJECTIVES: Doppler ultrasound (DUS) is the main imaging modality to evaluate vascular complications of pediatric liver transplants (LT). The current study aimed to determine reference values and their change over time.METHODS: A consecutive cohort of pediatric patients undergoing an LT were retrospectively included between 2015 and 2020. Timepoints for standardized DUS were intra-operative and postoperative (day 0), days 1-7, months 1 and 3, and years 1 and 2. DUS measurements of the hepatic artery (HA), portal vein (PV), and hepatic vein(s) (HV) were included if there were no complications during 2 years follow-up. Measurements consisted of: peak systolic velocity (PSV) and resistive index (RI) for the HA, PSV for the PV, and venous pulsatility index (VPI) for the HV. Generalized estimating equations were used to analyze change over time.RESULTS: One hundred twelve pediatric patients with 123 LTs were included (median age 3.3 years, interquartile range 0.7-10.1). Ninety-five HAs, 100 PVs, and 115 HVs without complications were included. Reference values for HA PSV and RI, PV PSV, and HV VPI were obtained for all timepoints (4043 included data points in total) and presented using 5th-95th percentiles and threshold values. All reference values changed significantly over time (p = 0.032 to p &lt; 0.001).CONCLUSIONS: DUS reference values of hepatic vessels in children after LT are presented, reference values change over time with specific vessel-dependent patterns. Timepoint-specific reference values improve the interpretation of DUS values and may help to better weigh their clinical significance.KEY POINTS: • Doppler ultrasound reference values of pediatric liver transplantations are not static but change over time. Applying the correct reference values for the specific timepoint may further improve the interpretation of the measurements. • The pattern of change over time of Doppler ultrasound measurements differs between the hepatic vessel and measurement; knowledge of these patterns may help radiologists to better understand normal postoperative hemodynamic changes.</p
    corecore