7 research outputs found

    Monitoring of saline tracer movement with vertically distributed self-potential measurements at the HOBE agricultural test site, Voulund, Denmark

    No full text
    The self-potential (SP) method is sensitive to water fluxes in saturated and partially saturated porous media, such as those associated with rainwater infiltration and groundwater recharge. We present a field-based study at the Voulund agricultural test site, Denmark, that is, to the best of our knowledge, the first to focus on the vertical self-potential distribution prior to and during a saline tracer test. A coupled hydrogeophysical modeling framework is used to simulate the SP response to precipitation and saline tracer infiltration. A layered hydrological model is first obtained by inverting dielectric and matric potential data. The resulting model that compares favorably with electrical resistance tomography models is subsequently used to predict the SP response. The electrokinetic contribution (caused by water fluxes in a charged porous soil) is modeled by an effective excess charge approach that considers both water saturation and pore water salinity. Our results suggest that the effective excess charge evolution prior to the tracer injection is better described by a recent flux-averaged model based on soil water retention functions than by a previously proposed volume-averaging model. This is the first time that raw vertically distributed SP measurements have been explained by a physically based model. The electrokinetic contribution cannot alone reproduce the SP data during the tracer test and an electro-diffusive contribution (caused by concentration gradients) is needed. The predicted amplitude of this contribution is too small to perfectly explain the data, but the shape is in accordance with the field data. This discrepancy is attributed to imperfect descriptions of electro-diffusive phenomena in partially saturated soils, unaccounted soil heterogeneity, and discrepancies between the measured and predicted electrical conductivities in the tracer infiltration area.Comment: 45 pages, 9 figures, 2 table

    Estimation of recharge from long-term monitoring of saline tracer transport using electrical resistivity tomography

    No full text
    We conducted a field experiment at the agricultural field site Voulund within the Danish hydrological observatory, HOBE, with the purpose of estimating recharge using geophysical methods. In September 2011, a saline tracer was added across a 142-m2 area at the surface at an application rate mimicking natural infiltration. The movement of the saline tracer front was monitored using cross-borehole electrical resistivity tomography (ERT); data were collected on a daily to weekly basis and continued for 1 yr after tracer application. The ERT data were inverted and corrected for temperature changes in the subsurface, and spatial moment analysis was used to calculate the tracer mass, position of the center of mass, and thereby the downwardly recharging flux. The recovered mass was underestimated by the ERT data by up to 50%. Mass balance errors are widely recognized and are a result of variable resolution of the tomographic models and smoothing applied in the inversion routine. The results were nonetheless in very good agreement with pore water samples collected and analyzed from five cores extracted within the tracer application area during the same period. Recharge during the 7.5 mo from September 2011 to the end of April 2012 was estimated to be about 500 mm using the ERT data. This value is in good accord with recharge estimates made based on drainage data from buried lysimeters located only meters away from the cross-borehole ERT array. This suggests that long-term automated ERT monitoring of a surface-applied tracer is a promising technique for estimating groundwater recharge
    corecore