194 research outputs found

    Exercise-induced respiratory muscle work: Effects on blood flow, fatigue and performance

    Get PDF
    This is the post print version of this article. The official published version can be obtained from the link below.In healthy subjects, heavy intensity endurance exercise places substantial demands on the respiratory muscles as breathing frequency, ventilation and the work of breathing rise over time. In the highly trained subject working at high absolute work rates, the ventilatory demand often causes varying degrees of expiratory flow limitation, sometimes accompanied by lung hyperinflation and, therefore, increased elastic work of breathing. Time-dependant increases in effort perceptions for both dyspnea and limb discomfort accompany these increased ventilatory demands. Similar responses to endurance exercise but at much lower exercise intensities also occur in patients with COPD and CHF. Note that these responses significantly influence exercise performance times in both health and disease. This effect was demonstrated by the marked reductions in the rate of rise of effort perceptions and the enhanced exercise performance times elicited by unloading the respiratory muscles using pressure support ventilation or proportional assist mechanical ventilation. In healthy fit subjects, unloading the inspiratory work of breathing by about one half increased performance by an average of 14% (Harms et al. 2000), and in CHF and COPD patients performance time more than doubled with respiratory muscle unloading (O’Donnell et al. 2001). Why are effort perceptions of limb discomfort markedly reduced and exercise performance increased when the respiratory muscles are unloaded? Our hypothesis is shown in Fig. 1

    Diagnostic and societal impact of implementing the syncope guidelines of the European Society of Cardiology (SYNERGY study)

    Get PDF
    Background: Syncope management is fraught with unnecessary tests and frequent failure to establish a diagnosis. We evaluated the potential of implementing the 2018 European Society of Cardiology (ESC) Syncope Guidelines regarding diagnostic yield, accuracy and costs.Methods: A multicentre pre-post study in five Dutch hospitals comparing two groups of syncope patients visiting the emergency department: one before intervention (usual care; from March 2017 to February 2019) and one afterwards (from October 2017 to September 2019). The intervention consisted of the simultaneous implementation of the ESC Syncope Guidelines with quick referral routes to a syncope unit when indicated. The primary objective was to compare diagnostic accuracy using logistic regression analysis accounting for the study site. Secondary outcome measures included diagnostic yield, syncope-related healthcare and societal costs. One-year follow-up data were used to define a gold standard reference diagnosis by applying ESC criteria or, if not possible, evaluation by an expert committee. We determined the accuracy by comparing the treating physician’s diagnosis with the reference diagnosis.Results: We included 521 patients (usual care, n = 275; syncope guidelines intervention, n = 246). The syncope guidelines intervention resulted in a higher diagnostic accuracy in the syncope guidelines group than in the usual care group (86% vs.69%; risk ratio 1.15; 95% CI 1.07 to 1.23) and a higher diagnostic yield (89% vs. 76%, 95% CI of the difference 6 to 19%). Syncope-related healthcare costs did not differ between the groups, yet the syncope guideline implementation resulted in lower total syncope-related societal costs compared to usual care (saving €908 per patient; 95% CI €34 to €1782).Conclusions: ESC Syncope Guidelines implementation in the emergency department with quick referral routes to a syncope unit improved diagnostic yield and accuracy and lowered societal costs.Trial registration: Netherlands Trial Register, NTR6268.</p

    Diagnostic and societal impact of implementing the syncope guidelines of the European Society of Cardiology (SYNERGY study)

    Get PDF
    Background: Syncope management is fraught with unnecessary tests and frequent failure to establish a diagnosis. We evaluated the potential of implementing the 2018 European Society of Cardiology (ESC) Syncope Guidelines regarding diagnostic yield, accuracy and costs.Methods: A multicentre pre-post study in five Dutch hospitals comparing two groups of syncope patients visiting the emergency department: one before intervention (usual care; from March 2017 to February 2019) and one afterwards (from October 2017 to September 2019). The intervention consisted of the simultaneous implementation of the ESC Syncope Guidelines with quick referral routes to a syncope unit when indicated. The primary objective was to compare diagnostic accuracy using logistic regression analysis accounting for the study site. Secondary outcome measures included diagnostic yield, syncope-related healthcare and societal costs. One-year follow-up data were used to define a gold standard reference diagnosis by applying ESC criteria or, if not possible, evaluation by an expert committee. We determined the accuracy by comparing the treating physician’s diagnosis with the reference diagnosis.Results: We included 521 patients (usual care, n = 275; syncope guidelines intervention, n = 246). The syncope guidelines intervention resulted in a higher diagnostic accuracy in the syncope guidelines group than in the usual care group (86% vs.69%; risk ratio 1.15; 95% CI 1.07 to 1.23) and a higher diagnostic yield (89% vs. 76%, 95% CI of the difference 6 to 19%). Syncope-related healthcare costs did not differ between the groups, yet the syncope guideline implementation resulted in lower total syncope-related societal costs compared to usual care (saving €908 per patient; 95% CI €34 to €1782).Conclusions: ESC Syncope Guidelines implementation in the emergency department with quick referral routes to a syncope unit improved diagnostic yield and accuracy and lowered societal costs.Trial registration: Netherlands Trial Register, NTR6268.</p

    Diagnostic and societal impact of implementing the syncope guidelines of the European Society of Cardiology (SYNERGY study)

    Get PDF
    Background: Syncope management is fraught with unnecessary tests and frequent failure to establish a diagnosis. We evaluated the potential of implementing the 2018 European Society of Cardiology (ESC) Syncope Guidelines regarding diagnostic yield, accuracy and costs.Methods: A multicentre pre-post study in five Dutch hospitals comparing two groups of syncope patients visiting the emergency department: one before intervention (usual care; from March 2017 to February 2019) and one afterwards (from October 2017 to September 2019). The intervention consisted of the simultaneous implementation of the ESC Syncope Guidelines with quick referral routes to a syncope unit when indicated. The primary objective was to compare diagnostic accuracy using logistic regression analysis accounting for the study site. Secondary outcome measures included diagnostic yield, syncope-related healthcare and societal costs. One-year follow-up data were used to define a gold standard reference diagnosis by applying ESC criteria or, if not possible, evaluation by an expert committee. We determined the accuracy by comparing the treating physician’s diagnosis with the reference diagnosis.Results: We included 521 patients (usual care, n = 275; syncope guidelines intervention, n = 246). The syncope guidelines intervention resulted in a higher diagnostic accuracy in the syncope guidelines group than in the usual care group (86% vs.69%; risk ratio 1.15; 95% CI 1.07 to 1.23) and a higher diagnostic yield (89% vs. 76%, 95% CI of the difference 6 to 19%). Syncope-related healthcare costs did not differ between the groups, yet the syncope guideline implementation resulted in lower total syncope-related societal costs compared to usual care (saving €908 per patient; 95% CI €34 to €1782).Conclusions: ESC Syncope Guidelines implementation in the emergency department with quick referral routes to a syncope unit improved diagnostic yield and accuracy and lowered societal costs.Trial registration: Netherlands Trial Register, NTR6268.</p

    The status of GEO 600

    Get PDF
    The GEO 600 laser interferometer with 600m armlength is part of a worldwide network of gravitational wave detectors. GEO 600 is unique in having advanced multiple pendulum suspensions with a monolithic last stage and in employing a signal recycled optical design. This paper describes the recent commissioning of the interferometer and its operation in signal recycled mode

    The Fueling and Evolution of AGN: Internal and External Triggers

    Full text link
    In this chapter, I review the fueling and evolution of active galactic nuclei (AGN) under the influence of internal and external triggers, namely intrinsic properties of host galaxies (morphological or Hubble type, color, presence of bars and other non-axisymmetric features, etc) and external factors such as environment and interactions. The most daunting challenge in fueling AGN is arguably the angular momentum problem as even matter located at a radius of a few hundred pc must lose more than 99.99 % of its specific angular momentum before it is fit for consumption by a BH. I review mass accretion rates, angular momentum requirements, the effectiveness of different fueling mechanisms, and the growth and mass density of black BHs at different epochs. I discuss connections between the nuclear and larger-scale properties of AGN, both locally and at intermediate redshifts, outlining some recent results from the GEMS and GOODS HST surveys.Comment: Invited Review Chapter to appear in LNP Volume on "AGN Physics on All Scales", Chapter 6, in press. 40 pages, 12 figures. Typo in Eq 5 correcte

    Search for Gravitational Waves from Primordial Black Hole Binary Coalescences in the Galactic Halo

    Get PDF
    We use data from the second science run of the LIGO gravitational-wave detectors to search for the gravitational waves from primordial black hole (PBH) binary coalescence with component masses in the range 0.2--1.0M⊙1.0 M_\odot. The analysis requires a signal to be found in the data from both LIGO observatories, according to a set of coincidence criteria. No inspiral signals were found. Assuming a spherical halo with core radius 5 kpc extending to 50 kpc containing non-spinning black holes with masses in the range 0.2--1.0M⊙1.0 M_\odot, we place an observational upper limit on the rate of PBH coalescence of 63 per year per Milky Way halo (MWH) with 90% confidence.Comment: 7 pages, 4 figures, to be submitted to Phys. Rev.

    All-sky search for long-duration gravitational wave transients with initial LIGO

    Get PDF
    We present the results of a search for long-duration gravitational wave transients in two sets of data collected by the LIGO Hanford and LIGO Livingston detectors between November 5, 2005 and September 30, 2007, and July 7, 2009 and October 20, 2010, with a total observational time of 283.0 days and 132.9 days, respectively. The search targets gravitational wave transients of duration 10-500 s in a frequency band of 40-1000 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. All candidate triggers were consistent with the expected background; as a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. For signals from black hole accretion disk instabilities, we set upper limits on the source rate density between 3.4×10-5 and 9.4×10-4 Mpc-3 yr-1 at 90% confidence. These are the first results from an all-sky search for unmodeled long-duration transient gravitational waves. © 2016 American Physical Society
    • …
    corecore