912 research outputs found

    Magnetocardiography with a modular spin-exchange relaxation free atomic magnetometer array

    Full text link
    We present a portable four-channel atomic magnetometer array operating in the spin exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design, and fibre coupled lasers. The modular design allows the independent positioning and orientation of each magnetometer, in principle allowing for non-planar array geometries. Using this array in a magnetically shielded room, we acquire adult magnetocadiograms. These measurements were taken with a 6-11 fT Hz^(-1/2) single-channel baseline sensitivity that is consistent with the independently measured noise level of the magnetically shielded room.Comment: 15 pages, 5 figure

    The design and thermo-structural analysis of target assembly for high intensity neutron source

    Get PDF
    The engineering design of an integrated target assembly of IFMIF lithium target was performed in IFMIF/EVEDA project for a high intensity neutron source. In the evaluation of the design, a thermos-structural analysis of was evaluated by ABAQUS code, and the modeling region was a part of the target assembly which was from the inlet nozzle to the outlet pipe. The material of the target assembly including the back plate was F82H steel. In the thermal-structural analysis, the normal operations and start/stop or abnormal operations were evaluated at 250 or 300 °C operation of Li flow in inlet pipe. The result showed that the temperature of the target assembly was evaluated to be still lower than the Li boiling point of 344 °C under a vacuum pressure of 10−3 Pa. In a temperature constant operation, the calculated stresses and displacements were small enough for thermal soundness of the target assembly in steady states. In a transient cooling process from 300 °C to 20 °C through 250 °C, the maximum Mises stress was found to be 372 MPa, which was lower than the yield stress at 300 °C. Keywords: High intensity neutron source, Target assembly, Thermo-structural analysis, Li target, IFMIF, F82

    Backward-angle photoproduction of π0\pi^0 mesons on the proton at EγE_\gamma = 1.5--2.4 GeV

    Full text link
    Differential cross sections and photon beam asymmetries for π0\pi^0 photoproduction have been measured at EγE_\gamma = 1.5--2.4 GeV and at the π0\pi^0 scattering angles, --1 << cosΘc.m.<\Theta_{c.m.} < --0.6. The energy-dependent slope of differential cross sections for uu-channel π0\pi^0 production has been determined. An enhancement at backward angles is found above EγE_\gamma = 2.0 GeV. This is inferred to be due to the uu-channel contribution and/or resonances. Photon beam asymmetries have been obtained for the first time at backward angles. A strong angular dependence has been found at Eγ>E_\gamma > 2.0 GeV, which may be due to the unknown high-mass resonances.Comment: 12 pages, 4 figures, submitted to PL
    • …
    corecore