328 research outputs found

    Development of an advanced Compton camera with gaseous TPC and scintillator

    Full text link
    A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM (Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV gamma-rays were 18∘18^\circ and 35∘35^\circ, respectively.Comment: 4 pages, 5 figures. Proceedings of the 6th International Workshop On Radiation Imaging Detector

    Investigating the hard X-ray emission from the hottest Abell cluster A2163 with Suzaku

    Get PDF
    We present the results from Suzaku observations of the hottest Abell galaxy cluster A2163 at z=0.2z=0.2. To study the physics of gas heating in cluster mergers, we investigated hard X-ray emission from the merging cluster A2163, which hosts the brightest synchrotron radio halo. We analyzed hard X-ray spectra accumulated from two-pointed Suzaku observations. Non-thermal hard X-ray emission should result from the inverse Compton (IC) scattering of relativistic electrons by the CMB photons. To measure this emission, the dominant thermal emission in the hard X-ray band must be modeled in detail. To this end, we analyzed the combined broad-band X-ray data of A2163 collected by Suzaku and XMM-Newton, assuming single- and multi-temperature models for thermal emission and the power-law model for non-thermal emission. From the Suzaku data, we detected significant hard X-ray emission from A2163 in the 12-60 keV band at the 28σ28\sigma level (or at the 5.5σ5.5\sigma level if a systematic error is considered). The Suzaku HXD spectrum alone is consistent with the single-T thermal model of gas temperature kT=14kT=14 keV. From the XMM data, we constructed a multi-T model including a very hot (kT=18kT=18 keV) component in the NE region. Incorporating the multi-T and the power-law models into a two-component model with a radio-band photon index, the 12-60 keV energy flux of non-thermal emission is constrained within 5.3±0.9(±3.8)×10−12 erg s−1cm−25.3 \pm 0.9 (\pm 3.8)\times 10^{-12}~{\rm erg\, s^{-1} cm^{-2}}. The 90% upper limit of detected IC emission is marginal (<1.2×10−11 erg s−1cm−2< 1.2\times 10^{-11}~{\rm erg\, s^{-1} cm^{-2}} in the 12-60 keV). The estimated magnetic field in A2163 is B>0.098 ΌGB > 0.098~{\rm \mu G}. While the present results represent a three-fold increase in the accuracy of the broad band spectral model of A2163, more sensitive hard X-ray observations are needed to decisively test for the presence of hard X-ray emission due to IC emission.Comment: 7 pages, 7 figures, A&A accepted. Minor correctio

    Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

    Full text link
    We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of 6×6×20mm36\times6\times20{\rm mm}^3 which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of 137^{137}Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.Comment: 9 pages, 6 figures, proceedings of the 7th International Workshop on Radiation Imaging Detectors (IWORID7), submitted to NIM

    Development of Large area Gamma-ray Camera with GSO(Ce) Scintillator Arrays and PSPMTs

    Get PDF
    We have developed a position-sensitive scintillation camera with a large area absorber for use as an advanced Compton gamma-ray camera. At first we tested GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under various conditions: the method of surface polishing, the concentration of Ce, and co-doping Zr. As a result, we chose the GSO(Ce) crystals doped with only 0.5 mol% Ce, and its surface polished by chemical etching as the scintillator of our camera. We also made a 16×\times16 cm2^2 scintillation camera which consisted of 9 position-sensitive PMTs (PSPMTs Hamamatsu flat-panel H8500), the each of which had 8×\times8 anodes with a pitch of 6 mm and coupled to 8×\times8 arrays of pixelated 6×6×\times6\times13 mm3^3 GSO(Ce) scintillators. For the readout system of the 576 anodes of the PMTs, we used chained resistors to reduce the number of readout channels down to 48 to reduce power consumption. The camera has a position resolution of less than 6mm and a typical energy resolution of 10.5% (FWHM) at 662 keV at each pixel in a large area of 16×\times16 cm2^2. %to choose the best scintillator for our project. Furthermore we constructed a 16×\times16 array of 3×3×\times3\times13 mm3^3 pixelated GSO(Ce) scintillators, and glued it to a PMT H8500. This camera had the position resolution of less than 3mm, over an area of 5×\times5 cm2^2, except for some of the edge pixels; the energy resolution was typically 13% (FWHM) at 662 keV.Comment: Proceedings of PSD7 appear in NIM

    Flood Risk Management: An Illustrative Approach

    Get PDF
    Widespread flooding with significant damage in many countries, such as the Philippines in 2013, highlights the ongoing need for effective flood risk management (FRM). This hinges on comprehensive access to and dissemination of information about the elements and the people at risk. Simulations, real-time graphs, and maps illustrate the spatial distribution of flood risks, spatial allocation and dissemination of flood effects, if flood risk reduction measures are not implemented, as well as the benefits to be derived from the effective implementation and maintenance of flood risk management measures not realized. Using precipitation, river water, and tide levels, a real-time monitoring site was set up for the Shirakawa River, Kumamoto, Japan. The data gathered from the July 2012 flood event is used as a demonstrator, illustrating a flood event as well as how to utilize the information provided on this site to determine the future time and possibility of flooding. Additionally, an electronically generated flood hazard map making process is being developed for distribution across Japan. These illustrative approaches can be utilized in cities and communities around the globe

    An evolved disk surrounding the massive main sequence star MWC 297?

    Full text link
    We present the results of the interferometric observations of the circumstellar disk surrounding MWC 297 in the continuum at 230 GHz (1.3 mm) and in the (J=2-1) rotational transitions of 12^{12}CO,13^{13}CO and C18^{18}O using the Submillimeter Array. At a distance of 250 pc, MWC 297 is one of the closest, young massive stars (M⋆_{\star} ∌\sim10 M⊙_{\odot}) to us. Compact continuum emission is detected towards MWC 297 from which we estimate a disk mass (gas+dust) of 0.07 M⊙_{\odot} and a disk radius of ≀\le 80 AU. Our result demonstrates that circumstellar disks can survive around massive stars well into their main sequence phase even after they have become optically visible. Complementing our observations with the data compiled from the literature, we find the submm dust opacity index ÎČ\beta to be between 0.1 and 0.3. If the emission is optically thin, the low value of ÎČ\beta indicates the presence of relatively large grains in the disk, possibly because of grain growth. We do not detect any CO emission associated with the continuum source. We argue that the 13^{13}CO emission from the disk is likely optically thin, in which case, we derive an upper limit to the gas mass which implies significant depletion of molecular gas in the disk. The mass of this disk and the evolutionary trends observed are similar to those found for intermediate mass Herbig Ae stars and low mass T Tauri stars.Comment: 4 pages, 3 Figures, accepted for publication in ApJ

    Molecular Evolution in Collapsing Prestellar Cores

    Get PDF
    We have investigated the evolution and distribution of molecules in collapsing prestellar cores via numerical chemical models, adopting the Larson-Penston solution and its delayed analogues to study collapse. Molecular abundances and distributions in a collapsing core are determined by the balance among the dynamical, chemical and adsorption time scales. When the central density n_H of a prestellar core with the Larson-Penston flow rises to 3 10^6 cm^{-3}, the CCS and CO column densities are calculated to show central holes of radius 7000 AU and 4000 AU, respectively, while the column density of N2H+ is centrally peaked. These predictions are consistent with observations of L1544. If the dynamical time scale of the core is larger than that of the Larson-Penston solution owing to magnetic fields, rotation, or turbulence, the column densities of CO and CCS are smaller, and their holes are larger than in the Larson-Penston core with the same central gas density. On the other hand, N2H+ and NH3 are more abundant in the more slowly collapsing core. Therefore, molecular distributions can probe the collapse time scale of prestellar cores. Deuterium fractionation has also been studied via numerical calculations. The deuterium fraction in molecules increases as a core evolves and molecular depletion onto grains proceeds. When the central density of the core is n_H=3 10^6 cm^{-3}, the ratio DCO+/HCO+ at the center is in the range 0.06-0.27, depending on the collapse time scale and adsorption energy; this range is in reasonable agreement with the observed value in L1544.Comment: 21 pages, 17 figure
    • 

    corecore