830 research outputs found

    Modelling the behaviour of microbulk Micromegas in Xenon/trimethylamine gas

    Get PDF
    We model the response of a state of the art micro-hole single-stage charge amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting of Xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side equilateral-triangle pattern with 50 um-diameter holes placed at its vertexes. Once the primary electrons are guided into the holes by virtue of an optimized field configuration, avalanches develop along the 50 um-height channels etched out of the original doubly copper-clad polyimide foil. In order to properly account for the strong field gradients at the holes' entrance as well as for the fluctuations of the avalanche process (that ultimately determine the achievable energy resolution), we abandoned the hydrodynamic framework, resorting to a purely microscopic description of the electron trajectories as obtained from elementary cross-sections. We show that achieving a satisfactory description needs additional assumptions about atom-molecule (Penning) transfer reactions and charge recombination to be made

    Improved induction of anti-melanoma T cells by adenovirus-5/3 fiber modification to target human DCs

    Get PDF
    To mount a strong anti-tumor immune response, non T cell inflamed (cold) tumors may require combination treatment encompassing vaccine strategies preceding checkpoint inhibition. In vivo targeted delivery of tumor-associated antigens (TAA) to dendritic cells (DCs), relying on the natural functions of primary DCs in situ, represents an attractive vaccination strategy. In this study we made use of a full-length MART-1 expressing C/B-chimeric adenoviral vector, consisting of the Ad5 capsid and the Ad3 knob (Ad5/3), which we previously showed to selectively transduce DCs in human skin and lymph nodes. Our data demonstrate that chimeric Ad5/3 vectors encoding TAA, and able to target human DCs in situ, can be used to efficiently induce expansion of functional tumor-specific CD8⁺ effector T cells, either from a naïve T cell pool or from previously primed T cells residing in the melanoma-draining sentinel lymph nodes (SLN). These data support the use of Ad3-knob containing viruses as vaccine vehicles for in vivo delivery. "Off-the-shelf" DC-targeted Ad vaccines encoding TAA could clearly benefit future immunotherapeutic approaches

    Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter

    Full text link
    As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candidates, both axions and WIMPs. Small ultra-low background Micromegas detectors are used to image the x-ray signal expected in axion helioscopes like CAST at CERN. Background levels as low as 0.8×1060.8\times 10^{-6} c keV1^{-1}cm2^{-2}s1^{-1} have already been achieved in CAST while values down to 107\sim10^{-7} c keV1^{-1}cm2^{-2}s1^{-1} have been obtained in a test bench placed underground in the Laboratorio Subterr\'aneo de Canfranc. Prospects to consolidate and further reduce these values down to 108\sim10^{-8} c keV1^{-1}cm2^{-2}s1^{-1}will be described. Such detectors, placed at the focal point of x-ray telescopes in the future IAXO experiment, would allow for 105^5 better signal-to-noise ratio than CAST, and search for solar axions with gaγg_{a\gamma} down to few 1012^{12} GeV1^{-1}, well into unexplored axion parameter space. In addition, a scaled-up version of these TPCs, properly shielded and placed underground, can be competitive in the search for low-mass WIMPs. The TREX-DM prototype, with \sim0.300 kg of Ar at 10 bar, or alternatively \sim0.160 kg of Ne at 10 bar, and energy threshold well below 1 keV, has been built to test this concept. We will describe the main technical solutions developed, as well as the results from the commissioning phase on surface. The anticipated sensitivity of this technique might reach 1044\sim10^{-44} cm2^2 for low mass (<10<10 GeV) WIMPs, well beyond current experimental limits in this mass range.Comment: Published in JCAP. New version with erratum incorporated (new figure 14

    TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection

    Get PDF
    Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass \sim0.300 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This article describes the actual setup, the first results of the comissioning in Ar+2\%iC4_4H10_{10} at 1.2 bar and the future updates for a possible physics run at the Canfranc Underground Laboratory in 2016. A first background model is also presented, based on Geant4 simulations and a muon/electron discrimination method. In a conservative scenario, TREX-DM could be sensitive to DAMA/LIBRA and other hints of positive WIMPs signals, with some space for improvement with a neutron/electron discrimination method or the use of other light gases.Comment: Proceedings of the 7th Symposium on Large TPCs for Low-Energy Rare Event Detectio

    Radiopurity of Micromegas readout planes

    Full text link
    Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing with dark matter, axions or double beta decay). In these experiments, the radiopurity of the detector components and surrounding materials is measured and finely controlled in order to keep the experimental background as low as possible. In the present paper, the first measurement of the radiopurity of Micromegas planes obtained by high purity germanium spectrometry in the low background facilities of the Canfranc Underground Laboratory (LSC) is presented. The obtained results prove that Micromegas readouts of the microbulk type are currently manufactured with radiopurity levels below 30 microBq/cm2 for Th and U chains and ~60 microBq/cm2 for 40K, already comparable to the cleanest detector components of the most stringent low background experiments at present. Taking into account that the studied readouts were manufactured without any specific control of the radiopurity, it should be possible to improve these levels after dedicated development.Comment: 15 pages, 2 figure

    Lessons from the operation of the "Penning-Fluorescent" TPC and prospects

    Get PDF
    We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays Penning effect and fluorescence in the near-visible region (300 nm). The concept, dubbed `Penning-Fluorescent' TPC, allows the simultaneous reconstruction of primary charge and scintillation with high topological and calorimetric fidelity
    corecore