11 research outputs found

    Adaptation of the transcriptional response to resistance exercise over 4 weeks of daily training

    Get PDF
    We present the time course of change in the muscle transcriptome 1 h after the last exercise bout of a daily resistance training program lasting 2, 10, 20, or 30 days. Daily exercise in rat tibialis anterior muscles (5 sets of 10 repetitions over 20 min) induced progressive muscle growth that approached a new stable state after 30 days. The acute transcriptional response changed along with progressive adaptation of the muscle phenotype. For example, expression of type 2B myosin was silenced. Time courses recently synthesized from human exercise studies do not demonstrate so clearly the interplay between the acute exercise response and the longer-term consequences of repeated exercise. We highlight classes of transcripts and transcription factors whose expression increases during the growth phase and declines again as the muscle adapts to a new daily pattern of activity and reduces its rate of growth. Myc appears to play a central role

    In-situ measurements of tensile forces in the tibialis anterior tendon of the rat in concentric, isometric, and resisted co-contractions.

    Get PDF
    Tensile-force transmitted by the tibialis anterior (TA) tendon of 11 anesthetized adult male Wistar rats (body-mass: 360.6 ± 66.3 g) was measured in-situ within the intact biomechanical system of the hind-limb using a novel miniature in-line load-cell. The aim was to demonstrate the dependence of the loading-profile experienced by the muscle, on stimulation-frequency and the resistance to shortening in a group of control-animals. Data from these acute-experiments shows the type of loading achievable by means of implantable electrical stimulators activating agonists or agonist/antagonist groups of muscles during programmed resistance-training in freely moving healthy subjects. Force-responses to electrical stimulation of the common peroneal nerve for single pulses and short bursts were measured in unloaded and isometric contractions. A less time-consuming approach to measure the force-frequency relationship was investigated by applying single bursts containing a series of escalating stimulus-frequencies. We also measured the range of loading attainable by programmed co-contraction of the TA-muscle with the plantar-flexor muscles for various combinations of stimulation-frequencies. The maximal average peak-force of single twitches was 179% higher for isometric than for unloaded twitches. Average maximal isometric tetanic-force per gramme muscle-mass was 16.5 ± 3.0 N g(-1), which agrees well with other studies. The standard and time-saving approaches to measure the force-frequency relationship gave similar results. Plantar-flexor co-activation produced greatly increased tension in the TA-tendon, similar to isometric contractions. Our results suggest that unloaded contractions may not be adequate for studies of resistance-training. Plantar-flexor co-contractions produced considerably higher force-levels that may be better suited to investigate the physiology and cell-biology of resistance-training in rodents

    Functional Electrical Stimulation Leads to Increased Volume of the Aged Thyroarytenoid Muscle.

    Get PDF
    OBJECTIVES/HYPOTHESIS: To reverse sarcopenia and increase the volumes of atrophied laryngeal muscles by functional electrical stimulation (FES) using a minimal invasive surgical procedure in an aged ovine model. STUDY DESIGN: Prospective animal study. METHODS: A stimulation electrode was placed unilaterally near the terminal adduction branch of the recurrent laryngeal nerve (RLN) adjacent to the right cricothyroid joint. The electrode was connected to an implant located subcutaneously at the neck region. Predesigned training patterns were automatically delivered by a bidirectional radio frequency link using a programming device and were repeated automatically by the implant every other day over 11 weeks in the awake animal. Outcome parameters comprised volumetric measurements based on three-dimensional reconstructions of the entire thyroarytenoid muscle (TAM), as well as gene expression analyses. RESULTS: We found significant increases of the volumes of the stimulated TAM of 11% and the TAM diameter at the midmembranous parts of the vocal folds of nearly 40%. Based on gene expression, we did not detect a shift of muscle fiber composition. CONCLUSIONS: FES of the terminal branches of the RLN is a secure and effective way to reverse the effects of age-related TAM atrophy and to increase volumes of atrophied muscles. LEVEL OF EVIDENCE: NA Laryngoscope, 2018

    Bilateral Functional Electrical Stimulation for the Treatment of Presbyphonia in a Sheep Model

    Get PDF
    Objectives: The aim of the study was to increase muscle volume and improve phonation characteristics of the aged ovine larynx by functional electrical stimulation (FES) using a minimally invasive surgical procedure. Methods: Stimulation electrodes were placed bilaterally near the terminal adduction branch of the recurrent laryngeal nerves (RLN). The electrodes were connected to battery powered pulse generators implanted subcutaneously at the neck region. Training patterns were programmed by an external programmer using a bidirectional radio frequency link. Training sessions were repeated automatically by the implant every other day for 1 week followed by every day for 8 weeks in the awake animal. Another group of animals were used as sham, with electrodes positioned but not connected to an implant. Outcome parameters included gene expression analysis, histological assessment of muscle fiber size, functional analysis, and volumetric measurements based on three-dimensional reconstructions of the entire thyroarytenoid muscle (TAM). Results: Increase in minimal muscle fiber diameter and an improvement in vocal efficiency were observed following FES, compared with sham animals. Conclusion: This is the first study to demonstrate beneficial effects in the TAM of FES at molecular, histological, and functional levels. FES of the terminal branches of the RLN reversed the effects of age-related changes and improved vocal efficiency

    A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats.

    Get PDF
    Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0-20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01-200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system

    Chronische Elektro-Stimulation des N. laryngeus recurrens zur Therapie der Altersstimme

    No full text

    Chronische Elektro-Stimulation des N. laryngeus recurrens zur Therapie der Altersstimme

    No full text
    corecore