268 research outputs found

    Helping your partner with chronic pain: the importance of helping motivation, received social support, and its timeliness

    Get PDF
    Objective Like all intentional acts, social support provision varies with respect to its underlying motives. Greater autonomous or volitional motives (e.g., enjoyment, full commitment) to help individuals with chronic pain (ICPs) are associated with greater well-being benefits for the latter, as indexed by improved satisfaction of their psychological needs for autonomy, competence, and relatedness. The present study investigates the processes explaining why partners’ autonomous or volitional helping motivation yields these benefits. Methods A total of 134 couples, where at least one partner had chronic pain, completed a 14-day diary. Partners reported on their daily helping motives, whereas ICPs reported on their daily received support, timing of help, need-based experiences, and pain. Results On days when partners provided help for volitional motives, ICPs indicated receiving more help, which partially accounted for the effect of autonomous helping motivation on ICP need-based experiences. Timing of help moderated the effects of daily received support on ICP need-based experiences. Conclusions Findings highlight the importance of ICPs of receiving support in general and the role of timing in particular, which especially matters when there is little support being received.info:eu-repo/semantics/acceptedVersio

    An Injection System for the CHIME/FRB Experiment

    Full text link
    Dedicated surveys searching for Fast Radio Bursts (FRBs) are subject to selection effects which bias the observed population of events. Software injection systems are one method of correcting for these biases by injecting a mock population of synthetic FRBs directly into the realtime search pipeline. The injected population may then be used to map intrinsic burst properties onto an expected signal-to-noise ratio (SNR), so long as telescope characteristics such as the beam model and calibration factors are properly accounted for. This paper presents an injection system developed for the Canadian Hydrogen Intensity Mapping Experiment Fast Radio Burst project (CHIME/FRB). The system was tested to ensure high detection efficiency, and the pulse calibration method was verified. Using an injection population of ~85,000 synthetic FRBs, we found that the correlation between fluence and SNR for injected FRBs was consistent with that of CHIME/FRB detections in the first CHIME/FRB catalog. We also noted that the sensitivity of the telescope varied strongly as a function of the broadened burst width, but not as a function of the dispersion measure. We conclude that some of the machine-learning based Radio Frequency Interference (RFI) mitigation methods used by CHIME/FRB can be re-trained using injection data to increase sensitivity to wide events, and that planned upgrades to the presented injection system will allow for determining a more accurate CHIME/FRB selection function in the near future.Comment: 13 pages, 8 figures. Submitted to A

    A Search for Fast Radio Bursts with the GBNCC Pulsar Survey

    Get PDF
    We report on a search for Fast Radio Bursts (FRBs) with the Green Bank Northern Celestial Cap (GBNCC) Pulsar Survey at 350 MHz. Pointings amounting to a total on-sky time of 61 days were searched to a DM of 3000 pc cm3^{-3} while the rest (23 days; 29% of the total time) were searched to a DM of 500 pc cm3^{-3}. No FRBs were detected in the pointings observed through May 2016. We estimate a 95% confidence upper limit on the FRB rate of 3.6×1033.6\times 10^3 FRBs sky1^{-1} day1^{-1} above a peak flux density of 0.63 Jy at 350 MHz for an intrinsic pulse width of 5 ms. We place constraints on the spectral index α\alpha by running simulations for different astrophysical scenarios and cumulative flux density distributions. The non-detection with GBNCC is consistent with the 1.4-GHz rate reported for the Parkes surveys for α>+0.35\alpha > +0.35 in the absence of scattering and free-free absorption and α>0.3\alpha > -0.3 in the presence of scattering, for a Euclidean flux distribution. The constraints imply that FRBs exhibit either a flat spectrum or a spectral turnover at frequencies above 400 MHz. These constraints also allow estimation of the number of bursts that can be detected with current and upcoming surveys. We predict that CHIME may detect anywhere from several to \sim50 FRBs a day (depending on model assumptions), making it well suited for interesting constraints on spectral index, the log NN-log SS slope and pulse profile evolution across its bandwidth (400-800 MHz).Comment: 18 pages, 10 figures, Accepted for publication in Ap

    Disposable Platform Provides Visual and Color-Based Point-of-Care Anemia Self-Testing

    Get PDF
    Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, standalone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels. METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying degrees and etiologies and compared hematology analyzer Hgb levels with POC Hgb levels, which were estimated via visual interpretation using a color scale and an optional smartphone app for automated analysis. RESULTS. POC Hgb levels correlated with hematology analyzer Hgb levels (r = 0.864 and r = 0.856 for visual interpretation and smartphone app, respectively), and both POC test methods yielded comparable sensitivity and specificity for detecting any anemia (n = 178) (/dl) (sensitivity: 90.2% and 91.1%, specificity: 83.7% and 79.2%, respectively) and severe anemia (n = 10) (/dl) (sensitivity: 90.0% and 100%, specificity: 94.6% and 93.9%, respectively). CONCLUSIONS. These results demonstrate the feasibility of this POC color-based diagnostic test for self-screening/self-monitoring of anemia. TRIAL REGISTRATION. Not applicable. FUNDING. This work was funded by the FDA-funded Atlantic Pediatric Device Consortium, the Georgia Research Alliance, Children\u27s Healthcare of Atlanta, the Georgia Center of Innovation for Manufacturing, and the InVenture Prize and Ideas to Serve competitions at the Georgia Institute of Technology

    Perspectives on the chemical etiology of breast cancer.

    Get PDF
    Multiple factors, known and unknown, contribute to human breast cancer. Hereditary, hormonal, and reproductive factors are associated with risk of breast cancer. Environmental agents, including chemical carcinogens, are modifiable risk factors to which over 70% of breast cancers have been attributed. Polymorphisms of drug-metabolizing enzymes may influence risk of breast cancer from environmental chemicals, dietary agents, and endogenous steroids. The environmental factors discussed in this review include pollutants, occupational exposures, tobacco smoke, alcohol, and diet. Aromatic amines are discussed as potential mammary carcinogens, with a focus on heterocyclic amine food pyrolysis products. These compounds are excreted into the urine after consumption of meals containing cooked meats and have recently been detected in the breast milk of lactating women

    Detection of Repeating FRB 180916.J0158+65 Down to Frequencies of 300 MHz

    Get PDF
    We report on the detection of seven bursts from the periodically active, repeating fast radio burst (FRB) source FRB 180916.J0158+65 in the 300-400-MHz frequency range with the Green Bank Telescope (GBT). Emission in multiple bursts is visible down to the bottom of the GBT band, suggesting that the cutoff frequency (if it exists) for FRB emission is lower than 300 MHz. Observations were conducted during predicted periods of activity of the source, and had simultaneous coverage with the Low Frequency Array (LOFAR) and the FRB backend on the Canadian Hydrogen Intensity Mapping Experiment (CHIME) telescope. We find that one of the GBT-detected bursts has potentially associated emission in the CHIME band (400-800 MHz) but we detect no bursts in the LOFAR band (110-190 MHz), placing a limit of α>1.0\alpha > -1.0 on the spectral index of broadband emission from the source. We also find that emission from the source is severely band-limited with burst bandwidths as low as \sim40 MHz. In addition, we place the strictest constraint on observable scattering of the source, << 1.7 ms, at 350 MHz, suggesting that the circumburst environment does not have strong scattering properties. Additionally, knowing that the circumburst environment is optically thin to free-free absorption at 300 MHz, we find evidence against the association of a hyper-compact HII region or a young supernova remnant (age << 50 yr) with the source.Comment: Accepted for publication in ApJ
    corecore