702 research outputs found

    The inverse relation between psychopathy and faking good: not response bias but true variance in psychopathic personality

    Get PDF
    The possibility to assess psychopathy through self-report is debated, amongst others, because psychopathic individuals may deliberately under-report psychopathic features (fake good). Meta-analytic research has shown an inverse relation between faking good and self-reported psychopathy, possibly indicating that faking good lowered psychopathy scores (response bias). Low faking good scores, could, however, also reflect true variance in psychopathic personality to the extent that it reflects a disregard of social conventions. Through a secondary analysis (n = 675), we show that controlling for faking good significantly weakens, rather than strengthens, the associations between psychopathy scores and antisocial behavior (alcohol and drug abuse, indirect aggression, and delinquency). These findings indicate that the inverse relation between faking good and self-reported psychopathy reflects true variance in psychopathy personality (i.e. low social desirability), not a response bias

    Lower leukotriene C4 levels in bronchoalveolar lavage fluid of asthmatic subjects after 2.5 years of inhaled corticosteroid therapy

    Get PDF
    Long-term treatment with inhaled corticosteroids has been shown to result in improvement of symptoms and lung function in subjects with asthma. Arachidonic acid (AA) metabolites are thought to play a role in the pathophysiology of asthma. It was assessed whether differences could be found in bronchoalveolar lavage (BAL) AA metabolite levels between subjects with asthma who were treated for 2.5 years with inhaled bronchodilators alone or in combination with inhaled corticosteroids. Prostaglandin (PG)D2, PGF2α, 6-keto-PGF1α, thromboxane B2, leukotriene (LT)C4 and LTB4 levels and cell numbers were assessed in BAL fluid from 22 non-smoking asthmatic subjects. They were participating in a randomized, double-blind multicentre drug trial over a period of 2.5 years. Results of the group treated with inhaled corticosteroids (CS+: beclomethasone 200 μg four times daily) were compared with the other group (CS−) which was treated with either ipratropium bromide (40 μg four times daily) or placebo. BAL LTC4 levels of asthmatic subjects were significantly lower after 2.5 years inhaled corticosteroid therapy (CS+, 9(1–17) pg/ml vs. CS−, 16(6-53) pg/ml; p = 0.01). The same trend was observed for the PGD2 levels. The results suggest that inhaled corticosteroids may exert their beneficial effect on lung function via a mechanism in which inhibition of LTC4 synthesis in the airways is involved

    Direct and Regioselective Di-alpha-fucosylation on the Secondary Rim of beta-Cyclodextrin

    Get PDF
    A straightforward glycosylation method is described to regio- and stereoselectively introduce two alpha-L-fucose moieties directly to the secondary rim of beta-cyclodextrin. Using NMR and MS fragmentation studies, the nonasaccharide structure was determined, which was also visualized using molecular dynamics simulations. The reported glycosylation method proved to be robust on gram-scale, and may be generally applied to directly glycosylate beta-cyclodextrins to make well-defined multivalent glycoclusters.</p

    Quantification of Movement in Stroke Patients under Free Living Conditions Using Wearable Sensors:A Systematic Review

    Get PDF
    Stroke is a main cause of long-term disability worldwide, placing a large burden on individuals and health care systems. Wearable technology can potentially objectively assess and monitor patients outside clinical environments, enabling a more detailed evaluation of their impairment and allowing individualization of rehabilitation therapies. The aim of this review is to provide an overview of setups used in literature to measure movement of stroke patients under free living conditions using wearable sensors, and to evaluate the relation between such sensor-based outcomes and the level of functioning as assessed by existing clinical evaluation methods. After a systematic search we included 32 articles, totaling 1076 stroke patients from acute to chronic phases and 236 healthy controls. We summarized the results by type and location of sensors, and by sensor-based outcome measures and their relation with existing clinical evaluation tools. We conclude that sensor-based measures of movement provide additional information in relation to clinical evaluation tools assessing motor functioning and both are needed to gain better insight in patient behavior and recovery. However, there is a strong need for standardization and consensus, regarding clinical assessments, but also regarding the use of specific algorithms and metrics for unsupervised measurements during daily life

    Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    Get PDF
    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. METHODS: Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. RESULTS: Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. CONCLUSION: The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments
    • …
    corecore