4,788 research outputs found
On-chip integrated nanowire device platform with controllable nanogap for manipulation, capturing, and electrical characterization of nanoparticles
Cataloged from PDF version of article.We propose and demonstrate nanowire (NW) device
platforms on-chip integrated using electric-field-assisted
self-assembly. This platform integrates from nanoprobes to microprobes,
and conveniently allows for on-chip manipulation, capturing,
and electrical characterization of nanoparticles (NPs).
Synthesizing segmented (Au–Ag–Au) NWs and aligning them
across predefined microelectrode arrays under ac electric field,
we controllably form nanogaps between the self-aligned end (Au)
segments by selectively removing the middle (Ag) segments. We
precisely control and tune the size of this middle section for
nanogap formation in the synthesis process. Using electric field
across nanogaps between these nanoprobes, we capture NPs to electrically
address and probe them at the nanoscale. This approach
holds great promise for the construction of single NP devices with
electrical nanoprobe contacts
Metamaterial based telemetric strain sensing in different materials
Cataloged from PDF version of article.We present telemetric sensing of surface strains on different industrial materials using split-ring-resonator based metamaterials. For wireless strain sensing, we utilize metamaterial array architectures for high sensitivity and low nonlinearity-errors in strain sensing. In this work, telemetric strain measurements in three test materials of cast polyamide, derlin and polyamide are performed by observing operating frequency shift under mechanical deformation and these data are compared with commercially-available wired strain gauges. We demonstrate that hard material (cast polyamide) showed low slope in frequency shift vs. applied load (corresponding to high Young's modulus), while soft material (polyamide) exhibited high slope (low Young's modulus). (C) 2010 Optical Society of America
Pearling: stroke segmentation with crusted pearl strings
We introduce a novel segmentation technique, called Pearling, for the semi-automatic extraction of idealized models of networks of strokes (variable width curves) in images. These networks may for example represent roads in an aerial photograph, vessels in a medical scan, or strokes in a drawing. The operator seeds the process by selecting representative areas of good (stroke interior) and bad colors. Then, the operator may either provide a rough trace through a particular path in the stroke graph or simply pick a starting point (seed) on a stroke and a direction of growth. Pearling computes in realtime the centerlines of the strokes, the bifurcations, and the thickness function along each stroke, hence producing a purified medial axis transform of a desired portion of the stroke graph. No prior segmentation or thresholding is required. Simple gestures may be used to trim or extend the selection or to add branches. The realtime performance and reliability of Pearling results from a novel disk-sampling approach, which traces the strokes by optimizing the positions and radii of a discrete series of disks (pearls) along the stroke. A continuous model is defined through subdivision. By design, the idealized pearl string model is slightly wider than necessary to ensure that it contains the stroke boundary. A narrower core model that fits inside the stroke is computed simultaneously. The difference between the pearl string and its core contains the boundary of the stroke and may be used to capture, compress, visualize, or analyze the raw image data along the stroke boundary
3D printing of PVA/hexagonal boron nitride/bacterial cellulose composite scaffolds for bone tissue engineering
In this study, a novel Polyvinyl Alcohol (PVA)/Hexagonal Boron Nitride (hBN)/Bacterial Cellulose (BC) composite, bone tissue scaffolds were fabricated using 3D printing technology. The printed scaffolds were characterized by fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), tensile testing, swelling behaviour, differential scanning calorimetry (DSC), and in vitro cell culture assay. Results demonstrated that bacterial cellulose addition affected the characteristic properties of the blends. Morphological studies revealed the homogenous dispersion of the bacterial cellulose within the 12 wt%PVA/0.25 wt%hBN matrix. Tensile strength of the scaffolds was decreased with the incorporation of BC and 12 wt%PVA/0.25 wt%hBN/0.5 wt%BC had the highest elongation at break value (93%). A significant increase in human osteoblast cell viability on 3D scaffolds was observed for 12 wt%PVA/0.25 wt%hBN/0.5 wt%BC. Cell morphology on composite scaffolds showed that bacterial cellulose doped scaffolds appeared to adhere to the cells. The present work deduced that bacterial cellulose doped 3D printed scaffolds with well-defined porous structures have considerable potential as a suitable tissue scaffold for bone tissue engineering (BTE)
A novel bio-microelectromechanical system for in vivo diagnostic monitoring of facture healing
[No abstract available
The Role Of Diffusion-Weighted Mr Imaging And Adc Values In The Diagnosis Of Gastric Tumors
Background: The aim of this study was to investigate the role of diffusion-weighted MR imaging (DWI) in the diagnosis of gastric tumors by means of measuring the apparent diffusion coefficient (ADC) values of these lesions, and making a comparison with the endoscopic biopsy results. Subjects and Methods: Seventy patients having gastric tumor constituted the case group. For the control group 30 healthy individuals were included. Abdominal MRI examinations were performed with a 1,5 Tesla unit. DWI examinations were obtained by single shot spin echoplanar imaging. The ADC was measured based on the tissue of the gastric tumoral entities and normal gastric mucosa in the control group. Results: Mean ADC values were 0,84 ± 0,17 × 10-3 mm2/s and 1,79 ± 0,08 × 10-3 mm2/s in gastric tumor group and in control group, respectively, being statistically significant (p < 0.05). There was no significance among ADC values of adenocarcinoma subgroups. The comparison of the ADC values in the adenocarcinoma and lymphoma cases were also found to be statistically significant. Conclusions: DWI is beneficial in the diagnosis of malignant gastric lesions by the aid of ADC measurements. Although ADC quantification seems to be invaluable in the evaluation of histopathologic subgroups of adeno - carcinoma, it can help in the diagnosis of gastric lymphoma
Bio-implantable passive on-chip RF-MEMS strain sensing resonators for orthopaedic applications
One out of ten bone fractures does not heal properly due to improper load distribution and strain profiles during the healing process. To provide implantable tools for the assessment of bone fractures, we have designed novel, bio-implantable, passive, on-chip, RF-MEMS strain sensors that rely on the resonance frequency shift with mechanical deformation. For this purpose, we modeled, fabricated and experimentally characterized two on-chip sensors with high quality factors for in vivo implantation. One of the sensors has an area of ∼0.12 mm2 with a quality factor of ∼60 and the other has an area of ∼0.07 mm2 with a quality factor of ∼70. To monitor the mechanical deformation by measuring the change in the resonance frequencies with the applied load, we employed a controllable, point load applying experimental setup designed and constructed for in vitro characterization. In the case of the sensor with the larger area, when we apply a load of 3920 N, we obtain a frequency shift of ∼330 MHz and a quality factor of ∼76. For the smaller sensor, the frequency shift and the quality factor are increased to 360 MHz and 95, respectively. These data demonstrate that our sensor chips have the capacity to withstand relatively high physiologic loads, and that the concomitant and very large resonant frequency shift with the applied load is achieved while maintaining a high signal quality factor. These experiments demonstrate that these novel sensors have the capacity for producing high sensitivity strain readout, even when the total device area is considerably small. Also, we have demonstrated that our bio-implantable, passive sensors deliver a telemetric, real-time readout of the strain on a chip. Placing two more resonators on the sides of the sensor to serve as transmitter and receiver antennas, we achieved to transfer contactless power and read out loads in the absence of direct wiring to the sensor. With this model, where telemetric measurements become simpler due to the fact that all sensor system is built on the same chip, we obtain a frequency shift of ∼190 MHz with an increase in the quality factor from ∼38 to ∼46 when a load of 3920 N is applied. Therefore, as a first proof of concept, we have demonstrated the feasibility of our on-chip strain sensors for monitoring the mechanical deformation using telemetry-based systems. © 2008 IOP Publishing Ltd
Metamaterial-based wireless RF-MEMS strain sensors
Approximately 10% of the fractures do not heal properly because of the inability to monitor fracture healing. Standard radiography is not capable of discriminating whether bone healing is occurring normally or aberrantly. We propose and develop an implantable wireless sensor that monitors strain on implanted hardware in real time telemetrically. This enables clinicians to monitor fracture healing. Here we present the development and demonstration of metamaterial-based radiofrequency (RF) micro-electro-mechanical system (MEMS) strain sensors for wireless strain sensing to monitor fracture healing. The operating frequency of these sensors shifts under mechanical loading; this shift is related to the surface strain of the implantable test material. In this work, we implemented metamaterials in two different architectures as bio-implantable wireless strain sensors for the first time. These custom-design metamaterials exhibit better performance as sensors than traditional RF structures (e.g., spiral coils) because of their unique structural properties (splits). They feature a low enough operating frequency to avoid the background absorption of soft tissue and yield higher Q-factors compared to the spiral structures (because their gaps have much higher electric field density). In our first metamaterial architecture of an 5x5 array, the wireless sensor shows high sensitivity (109kHz/kgf, 5.148kHz/microstrain) with low nonlinearity-error (<200microstrain). Using our second architecture, we then improved the structure of classical metamaterial and obtained nested metamaterials that incorporate multiple metamaterials in a compact nested structure and measured strain telemetrically at low operating frequencies. This novel nested metamaterial structure outperformed classical metamaterial structure as wireless strain sensors. By employing nested metamaterial architecture, the operating frequency is reduced from 529.8 MHz to 506.2 MHz while the sensitivity is increased from 0.72 kHz/kgf to 1.09 kHz/kgf. ©2010 IEEE
- …