19 research outputs found

    Osteitis Pubis After TURP: A Rare Complication Difficult to Recognize

    No full text
    TURP is a widespread urologic procedure that is performed by many urologists. This report describes a rare complication that causes serious morbidity because it is not recognized in time. This is also the first report of a prostatosymphyseal fistula treated without major surgery. Eventually diagnosis is made by a MRI 5 months after surgery. Decompressive surgery was necessary to treat pubic osteïtis with invalidating pain. Culture results revealed Escherichia coli but eventually the diagnosis was made by fistulography. Treatment consisted of bladder drainage and long-term antibiotic treatment and these could eventually heal the fistula

    Objective preclinical measures for bone conduction implants

    No full text
    The study evaluates the accuracy of predicting intracochlear pressure during bone conduction stimulation using promontory velocity and ear canal pressure, as less invasive alternatives to intracochlear pressure. Stimulating with a percutaneous bone conduction device implanted in six human cadaveric ears, measurements were taken across various intensities, frequencies, and stimulation positions. Results indicate that intracochlear pressure linearly correlates with ear canal pressure (R2 = 0.43, RMSE = 6.85 dB), and promontory velocity (R2 = 0.47, RMSE = 6.60 dB). Normalizing data to mitigate the influence of stimulation position leads to a substantial improvement in these correlations. R2 values increased substantially to 0.93 for both the ear canal pressure and the promontory velocity, with RMSE reduced considerably to 2.02 (for ear canal pressure) and 1.94 dB (for promontory velocity). Conclusively, both ear canal pressure and promontory velocity showed potential in predicting intracochlear pressure and the prediction accuracy notably enhanced when accounting for stimulation position. Ultimately, these findings advocate for the continued use of intracochlear pressure measurements to evaluate future bone conduction devices and illuminate the role of stimulation position in influencing the dynamics of bone conduction pathways

    Hydrogel impregnation of bone chips allows prolonged cefazolin release

    No full text
    Introduction To prevent infections after orthopedic surgery, intravenous antibiotics are administered perioperatively. Cefazolin is widely used as the prophylactic antibiotic of choice. Systemic antibiotic therapy may however be less effective in longstanding surgery where bone allografts are used. Bone chips have been shown to be an effective carrier for certain types of antibiotics. Bone allografts impregnated with antibiotics may therefore provide the necessary local antibiotic levels for prophylaxis. To be efficient, a prolonged release from these bonechips is required. In contrast to vancomycin, for which prolonged release has clearly been proven effective from Osteomycin®, a commercially available impregnated bone allograft, no prolonged release bone chip preparations have been described so far for cefazolin. We developed a protocol to bind cefazolin in the porous structure of bone chips by means of a hydrogel composed of proteins naturally present in the human body. Material and methods Three types of bone chips were evaluated: fresh frozen, decellularized frozen and decellularized lyophilized. Bone chips were incubated with 20 mg/ml cefazolin or treated with liquid hydrogel containing either 1 mg/ml fibrin or 1 mg/ml collagen and 20 mg/ml cefazolin. The cefazolin hydrogel was distributed in the porous structure by short vacuum treatment. Bone chips with cefazolin but without hydrogel were either incubated for 20 min- 4h or also treated with vacuum. Cefazolin elution of bone chips was carried out in fetal bovine serum and analyzed by Ultra Performance Liquid Chromatography – Diode Array Detection. Results Soaking of bone chips without hydrogel resulted in a quick release of cefazolin, which was limited to 4 hours. When vacuum was applied elution of >1 µg/ml cefazolin was measured for up to 36 hours. Combination with collagen hydrogel resulted in a higher cefazolin concentration released at 24 hours (3.9 vs 0.3 µg/ml), but not in a prolonged release. However, combination of decellularized frozen bone chips with fibrin hydrogel resulted in an initial release of 533 µg/ml followed by a gradual decline reaching the minimal inhibitory concentration for S. aureus at 72 hours (1.7 µg/ml), while not measurable anymore after 92 hours. Discussion Processed bone chips with hydrogel-cefazolin showed a markedly prolonged cefazolin release. When combined with a fibrin hydrogel, high initial peak levels of cefazolin were obtained, followed by a decreasing release over the following three days. This elution profile is desirable, since high initial levels are important to maximize anti-bacterial action whereas low levels of antibiotic for a limited time may stimulate osteogenesis. It is important that antibiotic release is ending after a few days as prolonged low levels of antibiotics are not clinically helpful and may lead to antibiotic resistance. Further preclinical studies are warranted to show effectiveness of hydrogel-cefazolin impregnated bone chips.status: publishe

    Hydrogel impregnation of bone chips allows prolonged cefazolin release

    No full text
    Introduction To prevent infections after orthopedic surgery, intravenous antibiotics are administered perioperatively. Cefazolin is widely used as the prophylactic antibiotic of choice. Systemic antibiotic therapy may however be less effective in longstanding surgery where bone allografts are used. Bone chips have been shown to be an effective carrier for certain types of antibiotics. Bone allografts impregnated with antibiotics may therefore provide the necessary local antibiotic levels for prophylaxis. To be efficient, a prolonged release from these bonechips is required. In contrast to vancomycin, for which prolonged release has clearly been proven effective from Osteomycin®, a commercially available impregnated bone allograft, no prolonged release bone chip preparations have been described so far for cefazolin. We developed a protocol to bind cefazolin in the porous structure of bone chips by means of a hydrogel composed of proteins naturally present in the human body. Material and methods Three types of bone chips were evaluated: fresh frozen, decellularized frozen and decellularized lyophilized. Bone chips were incubated with 20 mg/ml cefazolin or treated with liquid hydrogel containing either 1 mg/ml fibrin or 1 mg/ml collagen and 20 mg/ml cefazolin. The cefazolin hydrogel was distributed in the porous structure by short vacuum treatment. Bone chips with cefazolin but without hydrogel were either incubated for 20 min- 4h or also treated with vacuum. Cefazolin elution of bone chips was carried out in fetal bovine serum and analyzed by Ultra Performance Liquid Chromatography – Diode Array Detection. Results Soaking of bone chips without hydrogel resulted in a quick release of cefazolin, which was limited to 4 hours. When vacuum was applied elution of >1 µg/ml cefazolin was measured for up to 36 hours. Combination with collagen hydrogel resulted in a higher cefazolin concentration released at 24 hours (3.9 vs 0.3 µg/ml), but not in a prolonged release. However, combination of decellularized frozen bone chips with fibrin hydrogel resulted in an initial release of 533 µg/ml followed by a gradual decline reaching the minimal inhibitory concentration for S. aureus at 72 hours (1.7 µg/ml), while not measurable anymore after 92 hours. Discussion Processed bone chips with hydrogel-cefazolin showed a markedly prolonged cefazolin release. When combined with a fibrin hydrogel, high initial peak levels of cefazolin were obtained, followed by a decreasing release over the following three days. This elution profile is desirable, since high initial levels are important to maximize anti-bacterial action whereas low levels of antibiotic for a limited time may stimulate osteogenesis. It is important that antibiotic release is ending after a few days as prolonged low levels of antibiotics are not clinically helpful and may lead to antibiotic resistance. Further preclinical studies are warranted to show effectiveness of hydrogel-cefazolin impregnated bone chips.status: publishe

    Posterior pelvic ring involvement detected with CT taken within a week of admission in acute fragility fractures of the pelvis (FFP) does not predict failure of conservative treatment: a retrospective cohort study

    No full text
    Abstract Background Acute low energy pubic rami fractures in the elderly receive primarily conservative treatment. There is debate to what extent posterior ring involvement, which is detected superiorly by CT compared to X-ray, has an impact on outcome and may require modified treatment. We want to demonstrate if posterior ring involvement has an influence on different types of outcome in primarily conservatively treated acute FFP, questioning the usefulness of early CT. Additionally we analysed the early fracture pattern in cases where conservative treatment failed with need for secondary surgery. Methods A retrospective cohort study of 155 consecutive patients, recruited between 2009 and 2016, aged over 65 years diagnosed with an acute LE-PFr on X-ray at the emergency department of a single, level-one trauma centre and receiving an early CT. A set of outcome parameters was compared between patients with an isolated pubic rami fracture (CTia) and patients who had a combined posterior pelvic ring fracture (CTcp). Results There were 155 patients of whom 85.2% were female with a mean age of 83 years. 76.8% of patients living at home returned home and 15.5% moved to a nursing home. Mortality rate during hospitalisation was 6.4% and 14.8% at one year post-trauma. Secondary fracture displacement occurred in 22.6%. Secondary surgery was performed in 6 cases (3.9%). Median hospitalisation length of stay was 21 days (range 0 to 112 days). There was no significant association between the subgroups and change in residential status (p = 0.65), complications during hospitalisation (p = 0.75), mortality rate during admission (p = 0.75) and at 1 year (p = 0.88), readmission within 30 days (p = 0.46) and need for secondary surgery (p = 0.2). There was a significant increased median length of stay (p = 0.011) and rate of secondary displacement (p = 0.015) in subgroup CTcp. Secondary displacement had no impact on in-hospital complications (p = 0.7) nor mortality rate during admission (p = 0.79) or at 1 year (0.77). Early CT in patients who underwent secondary surgery showed stable B2.1 lesions in 4 of 6 cases. Conclusions Our data suggest that early CT in patients with conservatively treated acute LE-PFr in order to detect posterior lesions, has limited value in predicting failure of conservative treatment

    Reducing Artifacts in Intracochlear Pressure Measurements to Study Sound Transmission by Bone Conduction Stimulation in Humans

    No full text
    HYPOTHESIS: Intracochlear pressure (ICP) measurements during bone conduction (BC) stimulation may be affected by motion of the pressure sensor relative to the cochlear promontory bone, demonstrating the need to cement the sensor firmly to the cochlear bone. BACKGROUND: ICP is a promising measurement tool for investigating the cochlear drive in BC transmission, but its use is not yet standardized. Previous ICP studies have reported artificially increased pressure due to motion of the sensor relative to the temporal bone. The artifact can be reduced by firmly cementing the sensor to the bone, but this is destructive for the sensor. Previous studies used a custom-made sensor; the use of commercially available sensors, however, is more generic, but also more challenging to combine with the cement. Therefore, the goals of the current study are: firstly, to evaluate a non-destructive cementing method suitable for a commercially available sensor, and secondly, to investigate ICP measurements during BC stimulation in more detail. METHODS: To study the effect of sensor cementing, three fixation conditions were investigated on six fresh-frozen temporal bones: 1) alginate, 2) alginate and dental composite, 3) alginate and dental composite, released from micromanipulators. Pressures in scala tympani and vestibuli were measured simultaneously, while velocity measurements were performed on the cochlear promontory and sensor. The ratio between sensor and promontory bone velocity was computed to quantify the relative motion. RESULTS: For air conduction stimulation, results were in line with those from previous ICP studies, indicating that baseline measurements were valid and could be used to interpret the results obtained with BC stimulation. Results showed that cementing the sensors and releasing them from the micromanipulators is crucial for valid ICP measurements. When the sensors were only sealed with alginate, the pressure was overestimated, especially at low and mid-frequencies. When the sensors were cemented and held in the micromanipulators, the pressure was underestimated. Compared with the scala tympani measurements, ICP measurements showed a lower scala vestibuli pressure below 1 kHz, and a higher pressure above 1 kHz. CONCLUSION: Dental composite is effective as a cement to attach commercially available sensors to the cochlear promontory bone. When sensors are firmly attached, valid ICP measurements can be obtained with BC stimulation.status: publishe

    Atypical femoral fractures : three cases and a review of literature

    No full text
    In recent years, bisphosphonates and RANK-ligand inhibitors have become the mainstay of treatment for multiple types of osteoporosis, as well as several other metabolic bone diseases. Although rare, atypical femoral fracture is a recent but clearly defined complication of antiresorptive therapy with bisphosphonates, and likely also with denosumab. In this article, we present 3 different cases of atypical femoral fracture: an incomplete fracture linked to a bisphosphonate, an incomplete fracture linked to denosumab, and a complete atypical femoral fracture. Specific diagnostic steps and therapy are described. We also offer a complete overview of available literature concerning diagnosis, epidemiology, pathogenesis, treatment and future outlooks concerning this entity. Although antiresorptive therapy offers a very significant benefit in the prevention of osteoporotic fractures, clinicians should be aware of the possible complications, especially with long-term therapy