17 research outputs found
Effects of Surface Treatments and Cement Type on Shear Bond Strength between Titanium Alloy and All-Ceramic Materials.
This study aimed to evaluate the effects of surface treatments and resin cement on the adhesion of ceramic and ceramic-like materials to titanium. A total of 40 specimens (5 mm diameter) of each material (lithium disilicate glass ceramic (LDGC-IPS e.maxCAD), lithium silicate glass ceramic (LSGC-VITA Suprinity) and a polymer-infiltrated ceramic network (PICN-Vita Enamic)) were fabricated using CAD/CAM technologies. In total, 120 titanium (Ti) specimens were divided into 12 groups, and half of the titanium specimens were tribochemically coated using CoJet. The titanium and all-ceramic specimens were cemented using either Self-curing adhesive cement (SCAC-Panavia 21) or a Self-curing luting composite (SCLC-Multilink Hybrid Abutment). After 5000 cycles of thermal aging, the shear bond strength (SBS) test was conducted using a universal testing machine. The failure modes of the specimens were analyzed using stereomicroscopy, and additionally, the representative specimens were observed using Scanning Electron Microscopy. ANOVA was used for the statistical analysis (p < 0.05). The post-hoc Duncan test was used to determine significant differences between the groups. The mean SBS values (mean ± STD) ranged from 15 ± 2 MPa to 29 ± 6 MPa. Significantly higher SBS values were acquired when the titanium surface was tribochemically coated (p < 0.05). The SCLC showed higher SBS values compared to the SCAC. While the LDGC showed the highest SBS values, the PICN presented the lowest. The tribochemical coating on the cementation surfaces of the titanium increased the SBS values. The specimens cemented with the SCLC showed higher SBS values than those with the SCAC. Additionally, the SCLC cement revealed a more significant increase in SBS values when used with the LDGC. The material used for restoration has a high impact on SBS than those of the cement and surface conditioning
Effects of Surface Treatments and Cement Type on Shear Bond Strength between Titanium Alloy and All-Ceramic Materials
This study aimed to evaluate the effects of surface treatments and resin cement on the adhesion of ceramic and ceramic-like materials to titanium. A total of 40 specimens (5 mm diameter) of each material (lithium disilicate glass ceramic (LDGC-IPS e.maxCAD), lithium silicate glass ceramic (LSGC-VITA Suprinity) and a polymer-infiltrated ceramic network (PICN-Vita Enamic)) were fabricated using CAD/CAM technologies. In total, 120 titanium (Ti) specimens were divided into 12 groups, and half of the titanium specimens were tribochemically coated using CoJet. The titanium and all-ceramic specimens were cemented using either Self-curing adhesive cement (SCAC-Panavia 21) or a Self-curing luting composite (SCLC-Multilink Hybrid Abutment). After 5000 cycles of thermal aging, the shear bond strength (SBS) test was conducted using a universal testing machine. The failure modes of the specimens were analyzed using stereomicroscopy, and additionally, the representative specimens were observed using Scanning Electron Microscopy. ANOVA was used for the statistical analysis (p < 0.05). The post-hoc Duncan test was used to determine significant differences between the groups. The mean SBS values (mean ± STD) ranged from 15 ± 2 MPa to 29 ± 6 MPa. Significantly higher SBS values were acquired when the titanium surface was tribochemically coated (p < 0.05). The SCLC showed higher SBS values compared to the SCAC. While the LDGC showed the highest SBS values, the PICN presented the lowest. The tribochemical coating on the cementation surfaces of the titanium increased the SBS values. The specimens cemented with the SCLC showed higher SBS values than those with the SCAC. Additionally, the SCLC cement revealed a more significant increase in SBS values when used with the LDGC. The material used for restoration has a high impact on SBS than those of the cement and surface conditioning
Resolution Of Anterior Scleritis After Periodontal Therapy
Scleritis is a chronic inflammation that involves the outermost coat and the skeleton of the eye. Scleritis may be associated with a systemic or immune mediated disease and it might be caused by an infection, trauma or drug reaction. This case presents a patient with generalized chronic periodontitis and anterior diffuse scleritis. A 30-year-old female complained of pain and persistent scleritis in the left eye was referred to the Periodontology department due to her periodontal problems. She was treated with oral non steroidal anti-inflammatory drugs and topical medications (corticosteroid) for her scleritis during last two years. However, these treatments failed to control the progression of the disease. After periodontal examination, deep periodontal pockets and serious bone loss was detected radiographically. She was treated by flap procedures and 3 teeth were extracted. After a 4-month healing period, scleritis was resulted in rapid resolution.PubMe
The Relationship Between Maxillary Sinus Lateral Wall Thickness, Alveolar Bone Loss, And Demographic Variables: A Cross-Sectional Cone-Beam Computerized Tomography Study
Objectives: Sinus floor elevation and augmentation surgery is widely used as a reliable procedure to increase insufficient bone height in the posterior maxillary area. The purpose of the present clinical study was to determine the associations between periodontal bone loss (PBL), maxillary sinus lateral bone wall thickness, age, and gender using cone-beam computerized tomography (CBCT). Materials and Methods: The current retrospective study consists of 716 maxillary sinus CBCT images of 358 patients. The CBCT scans were assessed to detect the relationship between lateral wall thickness and PBL. ANOVA and Student t test analysis were used to determine the influence of PBL on sinus lateral wall thickness. Results: Sinus lateral wall thickness was significantly associated with PBL (p 0.05). However, there was a significant association between lateral wall thickness at 3 and 13 mm and age (p < 0.05). There were significant associations between PBL and age (p < 0.001), and PBL and gender (p < 0.05). Conclusions: PBL might have an association with maxillary sinus lateral bone wall thickness. Further studies are needed to confirm this possible relationship. (C) 2018 The Author(s) Published by S. Karger AG, BaselWoSScopu
Effect of Anti-Rotational Abutment Features and Novel Computerized Fabrication Techniques on the Marginal Fit of Implant-Supported Metal Copings
Purpose: An in vitro study to compare the marginal fit of cobalt-chromium (Co-Cr) metal copings fabricated with selective laser melting (SLM), computer-aided design and computer-aided manufacturing (CAD/CAM) milling, and lost-wax (LW) techniques, on abutments with two different antirotational features. Materials and Methods: A total of 60 stainless steel abutments with the same length and convergence angles were fabricated using a numerical control machining. Half of the abutments had one flat plane, while the other half had three grooves as an antirotation feature. Thirty abutments of each kind were then divided into three subgroups, and metal copings were fabricated with SLM, CAD/CAM milling, or the LW technique (n = 10). The metal copings were cemented with polycarboxylate cement. Marginal gap measurements were performed using a stereomicroscope at a magnification of × 45 and data were analyzed with two-way analysis of variance (ANOVA) tests. Results: The LW (p = 0.002) and CAD/CAM (p < 0.001) techniques exhibited increased marginal gaps on the abutments with a three groove antirotational feature; however, no significant difference was detected with the SLM technique (p = 0.259). The copings fabricated with the SLM technique demonstrated significantly lower gap values in both abutment types (p < 0.001). Conclusion: While all marginal gap values were within the clinically acceptable range (<120 µm), abutments with more antirotational grooves exhibited wider marginal gaps with the LW and CAD/CAM techniques. © 2020 by the American College of Prosthodontist
Evaluation Of Gingival Crevicular Fluid And Peri-Implant Sulcus Fluid Levels Of Periostin: A Preliminary Report
BackgroundPeriostin is a protein present in alveolar bone and periodontal ligament whose function is related to response to external forces. The aims of this study are to detect levels of periostin in peri-implant sulcular fluid (PISF) and gingival crevicular fluid (GCF) and to evaluate the relationship between periostin, pyridinoline cross-linked carboxyterminal telopeptide of Type I collagen (ICTP), and C-terminal cross-linked telopeptide of Type I collagen (CTX) levels and clinical inflammatory symptoms and duration of functional loading. MethodsThe study population comprised nine women and four men with mean age 43.23 12.48. Twenty bone-level designed dental implants (DIs) placed in molar or premolar sites, without any signs of peri-implant bone loss and with a restoration in function for at least 12 months, were included in the study with 20 contralateral natural teeth (NT) as controls. Clinical parameters and restoration dates of the implants were recorded. PISF, GCF, ICTP, CTX, and periostin levels were evaluated using enzyme-linked immunosorbent assay. ResultsICTP, CTX, and periostin levels were similar between DI and NT groups. There were no statistically significant differences between PISF and GCF values. When implants were grouped as healthy (gingival index [GI]=0) and inflamed (GI0), ICTP levels and PISF volume were lower in healthy implants compared with the inflamed group. Both periostin and CTX levels were negatively correlated with functioning time, suggesting less bone remodeling around DIs at later stages of functioning. ConclusionFindings of this study suggest collagen breakdown products may be used as markers to evaluate peri-implant metabolism.Wo
Effect of Anti-Rotational Abutment Features and Novel Computerized Fabrication Techniques on the Marginal Fit of Implant-Supported Metal Copings.
Purpose: An in vitro study to compare the marginal fit of cobalt-chromium (Co-Cr) metal copings fabricated with selective laser melting (SLM), computer-aided design and computer-aided manufacturing (CAD/CAM) milling, and lost-wax (LW) techniques, on abutments with two different anti-rotational features.
Materials and methods: A total of 60 stainless steel abutments with the same length and convergence angles were fabricated using a numerical control machining. Half of the abutments had one flat plane, while the other half had three grooves as an anti-rotation feature. Thirty abutments of each kind were then divided into three subgroups, and metal copings were fabricated with SLM, CAD/CAM milling, or the LW technique (n = 10). The metal copings were cemented with polycarboxylate cement. Marginal gap measurements were performed using a stereomicroscope at a magnification of × 45 and data were analyzed with two-way analysis of variance (ANOVA) tests.
Results: The LW (p = 0.002) and CAD/CAM (p<0.001) techniques exhibited increased marginal gaps on the abutments with a three groove anti-rotational feature; however, no significant difference was detected with the SLM technique (p = 0.259). The copings fabricated with the SLM technique demonstrated significantly lower gap values in both abutment types (p<0.001).
Conclusion: While all marginal gap values were within the clinically acceptable range (<120μm), abutments with more anti-rotational grooves exhibited wider marginal gaps with the LW and CAD/CAM techniques. This article is protected by copyright. All rights reserved
Nanofilled And Conventional Resin-Modified Glass Ionomer Fillings Combined With Connective Tissue Grafts For Treatment Of Gingival Recessions With Non-Carious Cervical Lesions
The aim of this study was to evaluate the clinical root coverage results of subepithelial connective tissue grafts (SCTG) performed on teeth with gingival recessions and non-carious cervical lesions (NCCLs) that were restored with cervical fillings and compare the results of two different filling materials: resin-modified glass ionomer (RMGIC) and nanoionomer cements (NIC). A total of 54 teeth with Miller Class I gingival recessions with or without NCCLs in 36 patients (28 females, 8 males) were treated with SCTGs. Cervical lesions were randomly treated with RMGIC or MC restorations. Periodontal clinical parameters, height of gingival recession (HGR), width of gingival recession (WGR), height of keratinized tissue, and dentin sensitivity were measured at baseline and 3, 6, and 12 months postoperatively. HGR and WGR values were statistically significantly reduced at all time points when compared to baseline values in all groups. There were no statistically significant differences between the groups in any clinical periodontal parameter (P > 0.05). The percentage of root coverage at 12 months was 89.5%, 90.1%, and 96.2% in the RMGIC, NIC, and control groups, respectively. Successful root coverage with connective tissue grafts may be achieved on teeth restored with RMGIC or NIC cervical fillings.WoSScopu
What is the rate of tobacco usage among dental school students?
Kuru, Leyla/0000-0002-7599-2409;WOS: 000467864900002