512 research outputs found

    Multiple-ionization of xenon atoms by positron impact

    Get PDF
    Previously the cross sections were measured for positronium formation and single ionization by positron impact for He and H2. With the same apparatus, slightly modified, the single and multiple ionization of xenon is now investigated. The principle of the method is the detection of ion and positron in time correlation which allows the discrimination of positronium formation (whereby the positron vanishes) and the destinction of single, double and triple impact ionization (which lead to different ion flight times from the gas target to the ion detector). By using secondary electrons from the positron moderator, similar measurements were performed on electron impact ionization. By comparing with literature values for electron multiple ionization cross sections, the detection-probability ratios were determined for the differently charged ions

    Surface topography of microtubule walls decorated with monomeric and dimeric kinesin constructs

    Get PDF
    The surface topography of opened-up microtubule walls (sheets) decorated with monomeric and dimeric kinesin motor domains was investigated by freeze-drying and unidirectional metal shadowing. Electron microscopy of surface-shadowed specimens produces images with a high signal/noise ratio, which enable a direct observation of surface features below 2 nm detail. Here we investigate the inner and outer surface of microtubules and tubulin sheets with and without decoration by kinesin motor domains. Tubulin sheets are flattened walls of microtubules, keeping lateral protofilament contacts intact. Surface shadowing reveals the following features: (i) when the microtubule outside is exposed the surface relief is dominated by the bound motor domains. Monomeric motor constructs generate a strong 8 nm periodicity, corresponding to the binding of one motor domain per beta -tubulin heterodimer. This surface periodicity largely disappears when dimeric kinesin motor domains are used for decoration, even though it is still visible in negatively stained or frozen hydrated specimens, This could be explained by disorder in the binding of the second (loosely tethered) kinesin head, and/or disorder in the coiled-coil tail. (ii) Both surfaces of undecorated sheets or microtubules, as well as the inner surface of decorated sheets, reveal a strong 4 nm repeat (due to the periodicity of tubulin monomers) and a weak 8 nm repeat (due to slight differences between alpha- and beta -tubulin). The differences between alpha- and beta -tubulin on the inner surface are stronger than expected from cryo-electron microscopy of unstained microtubules, indicating the existence of tubulin subdomain-specific surface properties that reflect the surface corrugation and hence metal deposition during evaporation. The 16 nm periodicity visible in some negatively stained specimens (caused by the pairing of cooperatively bound kinesin dimers) is not detected by surface shadowing

    Spiritual Dryness as a Measure of a Specific Spiritual Crisis in Catholic Priests: Associations with Symptoms of Burnout and Distress

    Get PDF
    Spirituality/religiosity is recognized as a resource to cope with burdening life events and chronic illness. However, less is known about the consequences of the lack of positive spiritual feelings. Spiritual dryness in clergy has been described as spiritual lethargy, a lack of vibrant spiritual encounter with God, and an absence of spiritual resources, such as spiritual renewal practices. To operationalize experiences of ``spiritual dryness'' in terms of a specific spiritual crisis, we have developed the ``spiritual dryness scale'' (SDS). Here, we describe the validation of the instrument which was applied among other standardized questionnaires in a sample of 425 Catholic priests who professionally care for the spiritual sake of others. Feelings of ``spiritual dryness'' were experienced occasionally by up to 40%, often or even regularly by up to 13%. These experiences can explain 44% of variance in daily spiritual experiences, 30% in depressive symptoms, 22% in perceived stress, 20% in emotional exhaustion, 19% in work engagement, and 21% of variance of ascribed importance of religious activity. The SDS-5 can be used as a specific measure of spiritual crisis with good reliability and validity in further studies

    VADER - A Satellite Mission Concept For High Precision Dark Energy Studies

    Get PDF
    We present a satellite mission concept to measure the dark energy equation of state parameter w with percent-level precision. The Very Ambitious Dark Energy Research satellite (VADER) is a multi-wavelength survey mission joining X-ray, optical, and IR instruments for a simultaneous spectral coverage from 4microns (0.3eV) to 10keV over a field of view (FoV) of 1 square degree. VADER combines several clean methods for dark energy studies, the baryonic acoustic oscillations in the galaxy and galaxy cluster power spectrum and weak lensing, for a joint analysis over an unrivalled survey volume. The payload consists of two XMM-like X-ray telescopes with an effective area of 2,800cm^2 at 1.5keV and state-of-the-art wide field DEPFET pixel detectors (0.1-10keV) in a curved focal plane configuration to extend the FoV. The X-ray telescopes are complemented by a 1.5m optical/IR telescope with 8 instruments for simultaneous coverage of the same FoV from 0.3 to 4 microns. The 8 dichroic-separated bands (u,g,r,z,J,H,K,L) provide accurate photometric galaxy redshifts, whereas the diffraction-limited resolution of the central z-band allows precise shape measurements for cosmic shear analysis. The 5 year VADER survey will cover a contiguous sky area of 3,500 square degrees to a depth of z~2 and will yield accurate photometric redshifts and multi-wavelength object parameters for about 175,000 galaxy clusters, one billion galaxies, and 5 million AGN. VADER will not only provide unprecedented constraints on the nature of dark energy, but will additionally extend and trigger a multitude of cosmic evolution studies to very large (>10 Gyrs) look-back times.Comment: 14 pages, 7 figures, accepted for publication in the SPIE conference proceeding

    Recognition of double-stranded DNA using energetically activated duplexes with interstrand zippers of 1-, 2-or 4-pyrenyl-functionalized O2 '-alkylated RNA monomers

    Get PDF
    Despite advances with triplex-forming oligonucleotides, peptide nucleic acids, polyamides and - more recently - engineered proteins, there remains an urgent need for synthetic ligands that enable specific recognition of double-stranded (ds) DNA to accelerate studies aiming at detecting, regulating and modifying genes. Invaders, i.e., energetically activated DNA duplexes with interstrand zipper arrangements of intercalator-functionalized nucleotides, are emerging as an attractive approach toward this goal. Here, we characterize and compare Invaders based on 1-, 2- and 4-pyrenyl-functionalized O2′-alkylated uridine monomers X–Z by means of thermal denaturation experiments, optical spectroscopy, force-field simulations and recognition experiments using DNA hairpins as model targets. We demonstrate that Invaders with +1 interstrand zippers of X or Y monomers efficiently recognize mixed-sequence DNA hairpins with single nucleotide fidelity. Intercalator-mediated unwinding and activation of the double-stranded probe, coupled with extraordinary stabilization of probe-target duplexes (ΔT(m)/modification up to +14.0 °C), provides the driving force for dsDNA recognition. In contrast, Z-modified Invaders show much lower dsDNA recognition efficiency. Thus, even very conservative changes in the chemical makeup of the intercalator-functionalized nucleotides used to activate Invader duplexes, affects dsDNA-recognition efficiency of the probes, which highlights the importance of systematic structure-property studies. The insight from this study will guide future design of Invaders for applications in molecular biology and nucleic acid diagnostics

    Circulating endothelial cells demonstrate an attenuation of endothelial damage by minimizing the extracorporeal circulation

    Get PDF
    ObjectiveDetachment of endothelial cells may represent serious injury of the endothelium after cardiopulmonary bypass. We investigated whether the extent of endothelial injury is related to the type of cardiopulmonary bypass system used (conventional or minimized) and determined circulating endothelial cells as well as von Willebrand factor and soluble thrombomodulin.MethodsTwenty patients scheduled for elective coronary bypass grafting were randomly assigned to either the minimal extracorporeal circulation system or the standard cardiopulmonary bypass. Ten healthy volunteers served as controls. Circulating endothelial cells per milliliter of full blood were perioperatively determined by immunomagnetic cell separation technique. Endothelial plasma markers were measured by enzyme-linked immunosorbent assay.ResultsPreoperative circulating endothelial cell numbers did not differ between the experimental groups, but were significantly higher than in the healthy controls (18.6 ± 5.6 vs 7.2 ± 3.8, P < .001). At 6 hours, circulating endothelial cell numbers increased significantly compared with baseline in both experimental groups and peaked at 12 hours after cardiopulmonary bypass initiation, each time with significantly lower values in the minimal extracorporeal circulation group (6 hours: 44.0 ± 9.9 vs 29.6 ± 9.8, P = .007; 12 hours: 48.1 ± 6.8 vs 31.8 ± 7.1, P < .001). Likewise, von Willebrand factor and soluble thrombomodulin postoperatively increased in both groups with a tendency toward lower levels in the minimal extracorporeal circulation group. Although circulating endothelial cells gradually declined, continually with lower numbers in the minimal extracorporeal circulation group, the endothelial plasma markers remained elevated during observation time.ConclusionsCirculating endothelial cells represent a novel marker of the intrinsic endothelial damage caused by cardiopulmonary bypass. Its analysis facilitates the evaluation of cardiopulmonary bypass modifications as the minimal extracorporeal circulation system could be proven to be less injurious to endothelium and myocardium

    Time-dependent changes in pulmonary surfactant function and composition in acute respiratory distress syndrome due to pneumonia or aspiration

    Get PDF
    BACKGROUND: Alterations to pulmonary surfactant composition have been encountered in the Acute Respiratory Distress Syndrome (ARDS). However, only few data are available regarding the time-course and duration of surfactant changes in ARDS patients, although this information may largely influence the optimum design of clinical trials addressing surfactant replacement therapy. We therefore examined the time-course of surfactant changes in 15 patients with direct ARDS (pneumonia, aspiration) over the first 8 days after onset of mechanical ventilation. METHODS: Three consecutive bronchoalveolar lavages (BAL) were performed shortly after intubation (T0), and four days (T1) and eight days (T2) after intubation. Fifteen healthy volunteers served as controls. Phospholipid-to-protein ratio in BAL fluids, phospholipid class profiles, phosphatidylcholine (PC) molecular species, surfactant proteins (SP)-A, -B, -C, -D, and relative content and surface tension properties of large surfactant aggregates (LA) were assessed. RESULTS: At T0, a severe and highly significant reduction in SP-A, SP-B and SP-C, the LA fraction, PC and phosphatidylglycerol (PG) percentages, and dipalmitoylation of PC (DPPC) was encountered. Surface activity of the LA fraction was greatly impaired. Over time, significant improvements were encountered especially in view of LA content, DPPC, PG and SP-A, but minimum surface tension of LA was not fully restored (15 mN/m at T2). A highly significant correlation was observed between PaO(2)/FiO(2 )and minimum surface tension (r = -0.83; p < 0.001), SP-C (r = 0.64; p < 0.001), and DPPC (r = 0.59; p = 0.003). Outcome analysis revealed that non-survivors had even more unfavourable surfactant properties as compared to survivors. CONCLUSION: We concluded that a profound impairment of pulmonary surfactant composition and function occurs in the very early stage of the disease and only gradually resolves over time. These observations may explain why former surfactant replacement studies with a short treatment duration failed to improve outcome and may help to establish optimal composition and duration of surfactant administration in future surfactant replacement studies in acute lung injury

    Hydrogenation on palladium nanoparticles supported by graphene nanoplatelets

    Get PDF
    Pd nanoparticles (1 wt %; mean size ∼4 nm) were supported on ∼2 μm sized, but few nanometers thick, graphene nanoplatelets (GNPs) and compared to 1 wt % Pd on activated carbon or γ-alumina. Catalyst morphology, specific surface area, and Pd particle size were characterized by SEM, BET, and TEM, respectively. H2-TPD indicated that GNPs intercalated hydrogen, which may provide additional H2 supply to the Pd nanoparticles during C2H4 hydrogenation. Whereas the two types of Pd/GNPs (NaOH vs calcinated) catalysts were less active than Pd/C and Pd/Al2O3 below 40 °C, at 55 °C they were about 3–4 times more active. As for example Pd/GNPs (NaOH) and Pd/Al2O3 exhibited not too different mean Pd particle size (3.7 vs 2.5 nm, respectively), the higher activity is attributed to the additional hydrogen supply likely by the metal/support interface, as suggested by the varying C2H4 and H2 orders on the different supports. Operando XANES measurements during C2H4 hydrogenation revealed the presence of Pd hydride. The Pd hydride was more stable for Pd/GNPs (NaOH) than for Pd/C, once more pointing to a better hydrogen supply by graphene nanoplatelets
    • …
    corecore