13 research outputs found

    Economic impact of remote monitoring on ordinary follow-up of implantable cardioverter defibrillators as compared with conventional in-hospital visits: a single-center prospective and randomized study

    Get PDF
    Few data are available on actual follow-up costs of remote monitoring (RM) of implantable defibrillators (ICD). Our study aimed at assessing current direct costs of 1-year ICD follow-up based on RM compared with conventional quarterly in-hospital follow-ups. Methods and results Patients (N=233) with indications for ICD were consecutively recruited and randomized at implant to be followed up for 1 year with standard quarterly inhospital visits or by RM with one in-hospital visit at 12 months, unless additional in-hospital visits were required due to specific patient conditions or RM alarms. Costs were calculated distinguishing between provider and patient costs, excluding RM device and service cost. The frequency of scheduled in-hospital visits was lower in the RM group than in the control arm. Follow-up required 47 min per patient/year in the RM arm versus 86 min in the control arm (p=0.03) for involved physicians, generating cost estimates for the provider of USD 45 and USD 83 per patient/- year, respectively. Costs for nurses were comparable. Overall, the costs associated with RM and standard follow-up were USD 103±27 and 154±21 per patient/year, respectively (p=0.01). RM was cost-saving for the patients: USD 97±121 per patient/year in the RM group versus 287± 160 per patient/year (p=0.0001). Conclusion The time spent by the hospital staff was significantly reduced in the RM group. If the costs for the device and service are not charged to patients or the provider, patients could save about USD 190 per patient/year while the hospital could save USD 51 per patient/year

    Economic analysis of remote monitoring in patients with implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators in the Trento area, Italy

    Get PDF
    Introduction: Remote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). Methods: Clinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. Results: In the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of −€4,771 and −€6,752 per patient in 2 years, in the payer and hospital perspective, respectively. Conclusion: RM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services

    Standard versus strict stability criteria in radiofrequency paroxysmal atrial fibrillation ablation using ablation index

    No full text
    Purpose: To compare the outcome of paroxysmal atrial fibrillation (AF) ablation via pulmonary vein isolation using Ablation Index (AI) with strict or standard stability criteria. Methods: We enrolled 130 consecutive naive patients affected by paroxysmal AF who underwent PVI at two high-volume centers. AI target was ≥380 at the posterior wall and ≥500 at the anterior wall. Strict versus standard stability criteria were set for Group 1 (65 patients) and Group 2 (65 patients), respectively. We compared those strategies with a historical cohort of 72 consecutive patients treated at same centers in the VISITALY study, using average force ≥10 g and strict stability criteria as target parameters. Interlesion distance target was <6 mm. Recurrence was defined as any AF, atrial tachycardia (AT) or atrial flutter (AFL) during the 12 months after ablation, excluding a 90-days blanking period. Results: Procedure duration (224.05 ± 47.21 vs. 175.61 ± 51.29 min; p <.001), fluoroscopy time (11.85 ± 4.38 vs. 10.46 ± 6.49 min; p =.019) and pericardial effusion rate (9.23% vs. 0%; p =.01) were higher in Group 1 than in Group 2. Freedom from AF/AT/AFL at 12 months was not significantly different (Group 1: 86.15%; Group 2: 90.77%; p =.42). Compared to VISITALY study, there were not significant differences in terms of recurrences. Conclusion: A strategy of PVI using AI with standard stability criteria performed the best in terms of procedure efficiency and safety. Twelve-months arrhythmia-free survival rate was comparable with other strategies pursuing an interlesion distance target <6 mm, regardless of the use of AI

    Temporary transvenous cardiac pacing: a survey on current practice

    No full text
    BACKGROUND: Temporary transvenous cardiac pacing (TTCP) is a standard procedure in current practice, despite limited coverage in consensus guidelines. However, many authors reported several complications associated with TTCP, especially development of infections of cardiac implantable electronic devices (CIED). The aim of this survey was to provide a country-wide picture of current practice regarding TTCP. METHODS: Data were collected using an online survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing. RESULTS: We collected data from 102 physicians, working in 81 Italian hospitals from 17/21 regions. Our data evidenced that different strategies are adopted in case of acute bradycardia with a tendency to limit TTCP mainly to advanced atrioventricular block. However, some centers reported a greater use in elective procedures. TTCP is usually performed by electrophysiologists or interventional cardiologists and, differently from previous reports, mainly by a femoral approach and with nonfloating catheters. We found high inhomogeneity regarding prevention of infections and thromboembolic complications and in post-TTCP management, associated with different TTCP volumes and a strategy for management of acute bradyarrhythmias. CONCLUSION: This survey evidenced a high inhomogeneity in the approaches adopted by Italian cardiologists for TTCP. Further studies are needed to explore if these divergences are associated with different long-term outcomes, especially incidence of CIED-related infections

    Differences between familial and sporadic dilated cardiomyopathy: ESC EORP Cardiomyopathy & Myocarditis registry

    Get PDF
    Aims: Dilated cardiomyopathy (DCM) is a complex disease where genetics interplay with extrinsic factors. This study aims to compare the phenotype, management, and outcome of familial DCM (FDCM) and non-familial (sporadic) DCM (SDCM) across Europe. Methods and results: Patients with DCM that were enrolled in the prospective ESC EORP Cardiomyopathy & Myocarditis Registry were included. Baseline characteristics, genetic testing, genetic yield, and outcome were analysed comparing FDCM and SDCM; 1260 adult patients were studied (238 FDCM, 707 SDCM, and 315 not disclosed). Patients with FDCM were younger (P\ua0<\ua00.01), had less severe disease phenotype at presentation (P\ua0<\ua00.02), more favourable baseline cardiovascular risk profiles (P\ua0 64\ua00.007), and less medication use (P\ua0 64\ua00.042). Outcome at 1\ua0year was similar and predicted by NYHA class (HR 0.45; 95% CI [0.25\u20130.81]) and LVEF per % decrease (HR 1.05; 95% CI [1.02\u20131.08]. Throughout Europe, patients with FDCM received more genetic testing (47% vs. 8%, P\ua0<\ua00.01) and had higher genetic yield (55% vs. 22%, P\ua0<\ua00.01). Conclusions: We observed that FDCM and SDCM have significant differences at baseline but similar short-term prognosis. Whether modification of associated cardiovascular risk factors provide opportunities for treatment remains to be investigated. Our results also show a prevalent role of genetics in FDCM and a non-marginal yield in SDCM although genetic testing is largely neglected in SDCM. Limited genetic testing and heterogeneity in panels provides a scaffold for improvement of guideline adherence

    Safety and efficacy of coronary sinus narrowing in chronic refractory angina: Insights from the RESOURCE study

    No full text
    Introduction: Refractory angina (RA) is considered the end-stage of coronary artery disease, and often has no interventional treatment options. Coronary sinus Reducer (CSR) is a recent addition to the therapeutic arsenal, but its efficacy has only been evaluated on small populations. The RESOURCE registry provides further insights into this therapy. Methods: The RESOURCE is an observational, retrospective registry that includes 658 patients with RA from 20 centers in Europe, United Kingdom and Israel. Prespecified endpoints were the amelioration of anginal symptoms evaluated with the Canadian Cardiovascular Society (CCS) score, the rates of procedural success and complications, and MACEs as composite of all-cause mortality, acute coronary syndromes, and stroke. Results: At a median follow-up of 502 days (IQR 225–1091) after CSR implantation, 39.7% of patients improved by ≥2 CCS classes (primary endpoint), and 76% by ≥1 class. Procedural success was achieved in 96.7% of attempts, with 3% of procedures aborted mostly for unsuitable coronary sinus anatomy. Any complication occurred in 5.7% of procedures, but never required bailout surgery nor resulted in intra- or periprocedural death or myocardial infarction. One patient developed periprocedural stroke after inadvertent carotid artery puncture. At the last available follow-up, overall mortality and MACE were 10.4% and 14.6% respectively. At one, three and five years, mortality rate at Kaplan-Meier analysis was 4%, 13.7%, and 23.4% respectively. Conclusions: CSR implantation is safe and reduces angina in patients with refractory angina

    Cardiac rehabilitation in very old patients: data from the Italian Survey onCardiac Rehabilitation-2008 (ISYDE-2008)--official report of the ItalianAssociation for Cardiovascular Prevention, Rehabilitation, and Epidemiology

    No full text
    BACKGROUND: Using data from the Italian SurveY on carDiac rEhabilitation-2008 (ISYDE-2008), this study provides insight into the level of implementation of cardiac rehabilitation (CR) in very old cardiac patients. METHODS: Data from 165 CR units were collected online from January 28 to February 10, 2008. RESULTS: The study cohort consisted of 2,281 patients (66.9 ± 11.8 years): 1,714 (62.4 ± 9.6 years, 78% male) aged<75 years and 567 aged ≥ 75 years (80.8 ± 4.5 years, 59% male). Compared with adults, a higher percentage of older patients were referred to CR programs after cardiac surgery or acute heart failure and showed more acute phase complications and comorbidity. Older patients were less likely discharged to home, more likely transferred to nursing homes, or discharged with social networks activation. Older patients had higher death rate during CR programs (odds ratio = 4.6; 95% confidence interval = 1.6-12.9; p = .004). CONCLUSION: The ISYDE-2008 survey provided a detailed snapshot of CR in very old cardiac patients

    Five waves of COVID-19 pandemic in Italy: results of a national survey evaluating the impact on activities related to arrhythmias, pacing, and electrophysiology promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)

    No full text
    Background: The subsequent waves of the COVID-19 pandemic in Italy had a major impact on cardiac care. Methods: A survey to evaluate the dynamic changes in arrhythmia care during the first five waves of COVID-19 in Italy (first: March–May 2020; second: October 2020–January 2021; third: February–May 2021; fourth: June–October 2021; fifth: November 2021–February 2022) was launched. Results: A total of 127 physicians from arrhythmia centers (34% of Italian centers) took part in the survey. As compared to 2019, a reduction in 40% of elective pacemaker (PM), defibrillators (ICD), and cardiac resynchronization devices (CRT) implantations, with a 70% reduction for ablations, was reported during the first wave, with a progressive and gradual return to pre-pandemic volumes, generally during the third–fourth waves, slower for ablations. For emergency procedures (PM, ICD, CRT, and ablations), recovery from the initial 10% decline occurred in most cases during the second wave, with some variability. However, acute care for atrial fibrillation, electrical cardioversions, and evaluations for syncope showed a prolonged reduction of activity. The number of patients with devices which started remote monitoring increased by 40% during the first wave, but then the adoption of remote monitoring declined. Conclusions: The dramatic and profound derangement in arrhythmia management that characterized the first wave of the COVID-19 pandemic was followed by a progressive return to the volume of activities of the pre-pandemic periods, even if with different temporal dynamics and some heterogeneity. Remote monitoring was largely implemented during the first wave, but full implementation is needed

    The Italian survey on cardiac rehabilitation-2008 (ISYDE-2008): a snapshot of current cardiac rehabilitation programmes and provides in Italy. Part 2: ISYDE-2008 investigators and directory of Italian cardiac rehabilitation centers.

    No full text
    corecore