5 research outputs found

    Association between Disease Severity, Heart Rate Variability (HRV) and Serum Cortisol Concentrations in Horses with Acute Abdominal Pain

    Get PDF
    Heart rate variability (HRV) is a noninvasive technique to detect changes in the autonomous nervous system. It has rarely been investigated in horses with colic. Therefore, the objective was to assess the evolution of HRV parameters and cortisol concentrations in horses with colic. The 43 horses included in this study were categorized into three groups according to the treatment (1, surgical; 2, conservative; 3, euthanized). The HRV and laboratory variables were measured at admission (T1), the day after admission (T2), and at discharge (T3) and compared between groups and over time with an ANOVA with Bonferroni correction. Relationships between the HRV parameters themselves and the laboratory variables was assessed by Pearson correlation coefficients. Evolution of the heart rate (HR) over time, mean normal to normal R intervals (meanNN) and cortisol concentrations indicate a decreased sympathetic stimulation over time in group 1 and 2, in contrast to group 3. For group 3, the meanNN and HR differed significantly to group 2 at T1 and to group 1 and 2 at T2. Treatment induced a change in the HRV and cortisol response in horses managed conservatively or surgically but not in horses that required euthanasia. However, further studies are required to assess the validity of HRV analyses in horses with colic

    Temporal metabolic profiling of bone healing in a caprine tibia segmental defect model

    Get PDF
    Bone tissue engineering is an emerging field of regenerative medicine, with a wide array of biomaterial technologies and therapeutics employed. However, it is difficult to objectively compare these various treatments during various stages of tissue response. Metabolomics is rapidly emerging as a powerful analytical tool to establish broad-spectrum metabolic signatures for a target biological system. Developing an effective biomarker panel for bone repair from small molecule data would provide an objective metric to readily assess the efficacy of novel therapeutics in relation to natural healing mechanisms. In this study we utilized a large segmental bone defect in goats to reflect trauma resulting in substantial volumetric bone loss. Characterization of the native repair capacity was then conducted over a period of 12 months through the combination of standard (radiography, computed tomography, histology, biomechanics) data and ultra-high-performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) metabolic profiling. Standard metrics demonstrated that samples formed soft callus structures that later mineralized. Small molecule profiles showed distinct temporal patterns associated with the bone tissue repair process. Specifically, increased lactate and amino acid levels at early time points indicated an environment conducive to osteoblast differentiation and extracellular matrix formation. Citrate and pyruvate abundances increased at later time points indicating increasing mineral content within the defect region. Taurine, shikimate, and pantothenate distribution profiles appeared to represent a shift toward a more homeostatic remodeling environment with the differentiation and activity of osteoclasts offsetting the earlier deposition phases of bone repair. The generation of a comprehensive metabolic reference portfolio offers a potent mechanism for examining novel biomaterials and can serve as guide for the development of new targeted therapeutics to improve the rate, magnitude, and quality of bone regeneration

    Screw removal torque data

    No full text
    This is an excel sheet with the peak removal torque values for each screw position in the plate. The peak removal torque values are divided between the non-self-tapping (NST) screws and self-tapping (ST) screws. Below the main table is the cortical fracture table with the frequencies of the cortical fracture occurrence during the screw placement of both screw types (NST and ST)

    Data from: Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model

    No full text
    Background Peak reverse torque (PRT) is a valid method to evaluate implants’ secondary stability in the healing bone. The secondary stability is achieved by the implant over time and it has been positively correlated with the implants’ osseointegration level. In other words, peak reverse torque is the force required to break the bone-implant interface. The purpose of this study was to compare the peak reverse torque for the self-tapping and non-self-tapping screws used in a dynamic compression plate–screw–bone construct after 60 days of loading when used to stabilize 2.5-cm defects in the tibia of goats. The second objective was to compare the peak removal torque of the screws placed in the different positions to evaluate the impact of construct biomechanics on implants osseointegration. Results In total, 176 non-self-tapping screws and 66 self-tapping screws were used to fix the 8-holes dynamic compression plates to the bones. The screws were placed in the tibiae from proximal (position sites 1,2, 3) to distal (position sites 4,5,6) and were removed 60 days post-implantation. The animals remained weight-bearing throughout the study period. The screws placed in the proximal diaphysis had significantly less peak reverse torque than screws placed in the distal diaphysis in both groups (p < 0.05). The peak reverse torque resistance was also significantly less for the non-self-tapping screws as compared with the self-tapping screws (p < 0.05). The intracortical fractures in the trans-cortex occurred significantly more frequently during the placement of non-self-tapping screws (p < 0.05) as compared with self-tapping screws (p < 0.05). Conclusions Based on these results, we concluded that self-tapping screws may be expected to maintain a more stable bone-implant interface during the first 60 days of loading as compared with non-self-tapping screws. This should be a consideration for orthopedic surgeons and scientists using bone plates to stabilize non-load sharing fractures when a stable plate-screw-bone interface is needed to ensure prolonged stability
    corecore