324 research outputs found

    Single Molecule Experiments Challenge the Strict Wave-Particle Dualism of Light

    Get PDF
    Single molecule techniques improve our understanding of the photon and light. If the single photon double slit experiment is performed at the “single photon limit” of a multi-atom light source, faint light pulses with more than one photon hamper the interpretation. Single molecules, quantum dots or defect centres in crystals should be used as light source. “Single photon detectors” do not meet their promise—only “photon number resolving single photon detectors” do so. Particularly, the accumulation time argument, the only safe basis for the postulate of a strictly particle like photon, has so far not yet been verified

    Photoluminescence of single colour defects in 50 nm diamond nanocrystals

    Full text link
    We used optical confocal microscopy to study optical properties of diamond 50 nm nanocrystals first irradiated with an electron beam, then dispersed as a colloidal solution and finally deposited on a silica slide. At room temperature, under CW laser excitation at a wavelength of 514.5 nm we observed perfectly photostable single Nitrogen-Vacancy (NV) colour defects embedded in the nanocrystals. From the zero-phonon line around 575 nm in the spectrum of emitted light, we infer a neutral NV0 type of defect. Such nanoparticle with intrinsic fluorescence are highly promising for applications in biology where long-term emitting fluorescent bio-compatible nanoprobes are still missing.Comment: proceedings of ICDS 23 conference (23rd International Conference on Defects in Semiconductors, July 24 - July 29, 2005, Awaji Island, Hyogo, Japan); to appear in "Physica B

    The Role of Gamma-Band Activity in the Representation of Faces: Reduced Activity in the Fusiform Face Area in Congenital Prosopagnosia

    Get PDF
    Congenital prosopagnosia (CP) describes an impairment in face processing that is presumably present from birth. The neuronal correlates of this dysfunction are still under debate. In the current paper, we investigate high-frequent oscillatory activity in response to faces in persons with CP. Such neuronal activity is thought to reflect higher-level representations for faces.Source localization of induced Gamma-Band Responses (iGBR) measured by magnetoencephalography (MEG) was used to establish the origin of oscillatory activity in response to famous and unknown faces which were presented in upright and inverted orientation. Persons suffering from congenital prosopagnosia (CP) were compared to matched controls.Corroborating earlier research, both groups revealed amplified iGBR in response to upright compared to inverted faces predominately in a time interval between 170 and 330 ms and in a frequency range from 50-100 Hz. Oscillatory activity upon known faces was smaller in comparison to unknown faces, suggesting a "sharpening" effect reflecting more efficient processing for familiar stimuli. These effects were seen in a wide cortical network encompassing temporal and parietal areas involved in the disambiguation of homogenous stimuli such as faces, and in the retrieval of semantic information. Importantly, participants suffering from CP displayed a strongly reduced iGBR in the left fusiform area compared to control participants.In sum, these data stress the crucial role of oscillatory activity for face representation and demonstrate the involvement of a distributed occipito-temporo-parietal network in generating iGBR. This study also provides the first evidence that persons suffering from an agnosia actually display reduced gamma band activity. Finally, the results argue strongly against the view that oscillatory activity is a mere epiphenomenon brought fourth by rapid eye-movements (micro saccades)

    Impact of 123 I-MIBG scintigraphy on clinical decision making in pheochromocytoma and paraganglioma

    Full text link
    CONTEXT Cross sectional imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is regarded as a first-choice modality for tumor localization in patients with pheochromocytoma and paraganglioma (PPGL). 123I-labeled metaiodobenzylguanidine (123I-MIBG) is widely used for functional imaging but the added diagnostic value is controversial. OBJECTIVE To establish the virtual impact of adding 123I-MIBG scintigraphy to CT or MRI on diagnosis and treatment of PPGL. DESIGN International multicenter retrospective study. INTERVENTION None. PATIENTS 236 unilateral adrenal, 18 bilateral adrenal, 48 unifocal extra-adrenal, 12 multifocal and 26 metastatic PPGL. MAIN OUTCOME MEASURES Patients underwent both anatomical imaging (CT and/or MRI) and 123I-MIBG scintigraphy. Local imaging reports were analyzed centrally by two independent observers who were blinded to the diagnosis. Imaging-based diagnoses determined by CT/MRI only, 123I-MIBG only, and CT/MRI combined with 123I-MIBG scintigraphy were compared with the correct diagnoses. RESULTS The rates of correct imaging-based diagnoses determined by CT/MRI only versus CT/MRI plus 123I-MIBG scintigraphy were similar: 89.4 versus 88.8%, respectively, (P=0.50). Adding 123I-MIBG scintigraphy to CT/MRI resulted in a correct change in the imaging-based diagnosis and ensuing virtual treatment in four cases (1.2%: two metastatic instead of non-metastatic, one multifocal instead of single, one unilateral instead of bilateral adrenal) at the cost of an incorrect change in seven cases (2.1%: four metastatic instead of non-metastatic, two multifocal instead of unifocal and one bilateral instead of unilateral adrenal). CONCLUSIONS For the initial localization of PPGL, the addition of 123I-MIBG scintigraphy to CT/MRI rarely improves the diagnostic accuracy at the cost of incorrect interpretation in others, even when 123I-MIBG scintigraphy is restricted to patients who are at risk for metastatic disease. In this setting, the impact of 123I-MIBG scintigraphy on clinical decision-making appears very limited

    Ácidos naftĂȘnicos no petrĂłleo

    Full text link
    Brazilian petroleum is known by its high acidity due to the presence of acidic constituents, especially naphthenic acids (NA). The total characterization of the NA in petrochemical samples has been receiving special attention in research and comprises an analytical challenge, mainly due to the complexity of their mixtures. Gas chromatography with mass detector (GC/MS) is the technique of analysis more used, but recently comprehensive two-dimensional gas chromatography (GC × GC) has been used, due to its high resolution, peak capacity and sensitivity. The goal of this article is to discuss the techniques for sample preparation and analysis of NA in petroleum

    An Antiproton Decelerator in the CERN PS Complex

    Get PDF
    The present CERN PS low-energy antiproton complex involves 4 machines to collect, cool, decelerate and supply experiments with up to 1010 antiprotons per pulse and per hour of momenta ranging from 0.1 to 2 GeV/c. In view of a possible future physics programme requiring low energy antiprotons, mainly to carry out studies on antihydrogen, a simplified scheme providing at low cost antiprotons at 100 MeV/c has been studied. It requires only one machine, the present Antiproton Collector (AC) converted into a cooler and decelerator (Antiproton Decelerator, AD) and delivering beam to experiments in the hall of the present Antiproton Accumulator Complex (AAC) [1]. This paper describes the feasibility study of such a scheme [2]

    The antiproton decelerator: AD

    Get PDF
    A simplified scheme for the provision of antiprotons at 100 MeV/c based on fast extraction is described. The scheme uses the existing production target area and the modified Antiproton Collector Ring in their current location. The physics programme is largely based on capturing and storing antiprotons in Penning traps for the production and spectroscopy of antihydrogen. The machine modifications necessary to deliver batches of 1 107 /min at 100 MeV/c are described. Details of the machine layout and the experimental area in the existing AAC Hall are given

    The antiproton decelerator (AD), a simplified antiproton source (feasibility study)

    Get PDF
    In view of a possible future physics programme concerning antihydrogen a simplified scheme for the provision of antiprotons of a few MeV has been studied. It uses the present target area and the modified Antiproton Collector (AC) in its present location. In this report all the systems are reviewed and their modifications discussed
    • 

    corecore