78 research outputs found

    Multimodality Imaging in Carotid Web

    Get PDF
    Purpose: Carotid web (CaW) is an underrecognized cause of cryptogenic stroke in young patients. The optimal imaging for CaW is unknown. We aim to evaluate the diagnostic accuracy of diverse imaging modalities for the diagnosis of CaW.Methods: Retrospective analysis of institutional neurovascular database was performed to identify patients with multimodal (CT angiogram–CTA, digital subtraction angiogram–DSA, and/or ultrasound–US) imaging diagnosis of CaW or atherosclerosis. Baseline clinical demographics were recorded. Blinded image analysis was performed for each imaging modality by separate readers. Discrepancies were settled by consensus. Two-sided Cohen's Kappa (κ) coefficient was used to evaluate the inter-rater agreement for the etiological diagnosis between imaging modalities.Results: Thirty patients/60 carotids were evaluated by CTA and 55 carotids were included. Patients with symptomatic CaW (n = 20), compared to individuals with atherosclerosis (n = 10), were younger (49 ± 9 vs. 60 ± 8 years; p < 0.01), more commonly female (75% vs. 30%; p = 0.01), and less frequently presented vascular risk factors: Hypertension (40% vs. 100%; p < 0.01), hyperlipidemia (0% vs. 50%; p < 0.01), diabetes (10% vs. 40%; p = 0.05), and smoking (5% vs. 70%; p < 0.01). High inter-rater correlation strength existed for CTA (n = 55; κ = 0.88; p < 0.0001) and DSA (n = 28; κ = 0.86, p < 0.0001) readers for lesion diagnosis while US inter-rater agreement was lower (κ = 0.553; p = 0.001). Across modalities CTA and DSA shared very high strength of agreement (κ = 0.92; p < 0.0001), compared to a less pronounced agreement between US and CTA (κ = 0.553; p = 0.001). The strength of correlation between DSA-CTA was significantly more robust as compared to US-CTA (Z = 3.58; p = 0.0003).Conclusion: CTA and DSA demonstrated comparable and superior performance as compared to US in the diagnosis of CaW

    Looking the Part: Social Status Cues Shape Race Perception

    Get PDF
    It is commonly believed that race is perceived through another's facial features, such as skin color. In the present research, we demonstrate that cues to social status that often surround a face systematically change the perception of its race. Participants categorized the race of faces that varied along White–Black morph continua and that were presented with high-status or low-status attire. Low-status attire increased the likelihood of categorization as Black, whereas high-status attire increased the likelihood of categorization as White; and this influence grew stronger as race became more ambiguous (Experiment 1). When faces with high-status attire were categorized as Black or faces with low-status attire were categorized as White, participants' hand movements nevertheless revealed a simultaneous attraction to select the other race-category response (stereotypically tied to the status cue) before arriving at a final categorization. Further, this attraction effect grew as race became more ambiguous (Experiment 2). Computational simulations then demonstrated that these effects may be accounted for by a neurally plausible person categorization system, in which contextual cues come to trigger stereotypes that in turn influence race perception. Together, the findings show how stereotypes interact with physical cues to shape person categorization, and suggest that social and contextual factors guide the perception of race

    Hyperacute unilateral contrast-induced parotiditis during cerebral angiography

    No full text
    An uncommon complication of iodinated contrast administration is the development of bilateral sialadenitis. We report a unique case of hyperacute unilateral parotiditis during diagnostic cerebral angiography of the external carotid artery, which mimicked possible iatrogenic vascular event associated with cerebral endovascular procedures. Discussion includes the differential diagnosis, diagnostic studies, and treatments for this unusual condition

    Cervical Carotid Pseudo-occlusions And False Dissections: Intracranial Occlusions Masquerading As Extracranial Occlusions

    No full text
    Background and Purpose Pseudo-occlusion (PO) of the cervical internal carotid artery (ICA) refers to an isolated occlusion of the intracranial ICA that appears as an extracranial ICA occlusion on computed tomography angiography (CTA) or digital subtraction angiography because of blockage of distal contrast penetration by a stagnant column of unopacified blood. We aim to better characterize this poorly recognized entity. Methods Retrospective review of an endovascular database (2010-2015; n=898). Only patients with isolated intracranial ICA occlusions as confirmed by angiographic exploration were included. CTA and digital subtraction angiography images were categorized according to their apparent site of occlusion as (1) extracranial ICA PO or (2) discernible intracranial ICA occlusion. Results Cervical ICA PO occurred in 21/46 (46%) patients on CTA (17 proximal cervical; 4 midcervical). Fifteen (71%) of these patients also had PO on digital subtraction angiography. A flame-shaped PO mimicking a carotid dissection was seen in 7 (33%) patients on CTA and in 6 (29%) patients on digital subtraction angiography. Patients with and without CTA PO had similar age (64.817.1 versus 60.2 +/- 15.7 years; P=0.35), sex (male, 47% versus 52%; P=1.00), and intravenous tissue-type plasminogen activator use (38% versus 40%; P=1.00). The rates of modified Treatment In Cerebral Ischemia 2b-3 reperfusion were 71.4% in the PO versus 100% in the non-PO cohorts (P<0.01). The rates of parenchymal hematoma, 90-day modified Rankin Scale score 0-2, and 90-day mortality were 4.8% versus 8% (P=0.66), 40% versus 66.7% (P=0.12), and 25% versus 21% (P=0.77) in PO versus non-PO patients, respectively. Multivariate analysis indicated that PO patients had lower chances of modified Treatment In Cerebral Ischemia 3 reperfusion (odds ratio 0.14; 95% confidence interval 0.02-0.70; P=0.01). Conclusions Cervical ICA PO is a relatively common entity and may be associated with decreased reperfusion rates.48377477

    Safety and efficacy of the Pipeline Flex embolization device with Shield Technology for the acute treatment of ruptured internal carotid artery pseudoaneurysms: a multi-institution case series

    No full text
    Objective: Ruptured blister, dissecting, and iatrogenic pseudoaneurysms are rare pathologies that pose significant challenges from a treatment standpoint. Endovascular treatment via flow diversion represents an increasingly popular option; however, drawbacks include the requirement for dual antiplatelet therapy and the potential for thromboembolic complications, particularly acute complications in the ruptured setting. The Pipeline Flex embolization device with Shield Technology (PED-Shield) offers reduced material thrombogenicity, which may aid in the treatment of ruptured internal carotid artery pseudoaneurysms. Methods: The authors conducted a multi-institution, retrospective case series to determine the safety and efficacy of PED-Shield for the treatment of ruptured blister, dissecting, and iatrogenic pseudoaneurysms of the internal carotid artery. Clinical, radiographic, treatment, and outcomes data were collected. Results: Thirty-three patients were included in the final analysis. Seventeen underwent placement of a single device, and 16 underwent placement of two devices. No thromboembolic complications occurred. Four patients were maintained on aspirin alone, and all others were treated with long-term dual antiplatelet therapy. Among patients with 3-month follow-up, 93.8% had a modified Rankin Scale score of 0-2. Complete occlusion at follow-up was observed in 82.6% of patients. Conclusions: PED-Shield represents a new option for the treatment of ruptured blister, dissecting, and iatrogenic pseudoaneurysms of the internal carotid artery. The reduced material thrombogenicity appeared to improve the safety of the PED-Shield device, as this series demonstrated no thromboembolic complications even among patients treated with only single antiplatelet therapy. The efficacy of PED-Shield reported in this series, particularly with placement of two devices, demonstrates its potential as a first-line treatment option for these pathologies

    Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: mid-term results

    No full text
    BACKGROUND: The off-label use of flow diverters in the treatment of distal aneurysms continues to be debated. OBJECTIVE: To report our multicenter experience in the treatment of complex anterior cerebral artery aneurysms with the Pipeline embolization device (PED). METHODS: The neurointerventional databases of the four participating institutions were retrospectively reviewed for aneurysms treated with PED between October 2011 and January of 2016. All patients treated for anterior cerebral artery aneurysms were included in the analysis. Clinical presentation, location, type, vessel size, procedural complications, clinical and imaging follow-up were included in the analysis. RESULTS: Twenty patients (13 female) with 20 aneurysms met the inclusion criteria in our study. Fifteen aneurysms were classified as saccular and five as fusiform (mean size 7.3 mm). Thirteen aneurysms were located in the anterior communicating region (ACOM or A1/2 junction), six were A2-pericallosal, and one was located in the A1 segment. Six patients had presented previously with subarachnoid hemorrhage and had their aneurysms initially clipped or coiled. There was one minor event (a small caudate infarct) and one major event (intraparenchymal hemorrhage). Sixteen of the 20 patients had angiographic follow-up (mean 10 months). Eleven aneurysms were completely occluded, one had residual neck, and four had residual aneurysm filling. CONCLUSIONS: The treatment of complex anterior cerebral artery aneurysms with the PED as an alternative for patients who are not good candidates for conventional methods is technically feasible and safe. Mid-term results are promising but larger series with long-term follow-up are required to assess its effectiveness
    • …
    corecore