7 research outputs found

    Left ventricular strain values using 3D speckle-tracking echocardiography in healthy adults aged 20 to 72 years

    Get PDF
    Three dimensional speckle tracking echocardiography (3D-STE) is a novel modality for the assessment of left ventricular strain (LVS). The aim of our study is to provide single vendor normative strain values measured with 3D-STE in healthy adult caucasians. One hundred fifty-five healthy subjects aged 20 to 72 years (≥ 28 subjects per decile) were prospectively included and examined with 2D and 3D transthoracic echocardiography. In 105 both 3D and 2D-STE were feasible (71%, mean age 44 ± 14 years, 51% female). Mean 3D tangential strain (3D-TS) was − 32 ± 2.9%. 3D global longitudinal strain (3D-GLS) demonstrated a significant but not very strong correlation with 2D-GLS values (− 19.7 ± 1.8% vs − 20.4 ± 2.2%, r = 0.462, p < 0.001). No gender difference was observed in 3D strain parameters. 3D-GLS decreased with increasing age stratum (p = 0.024). LVEF was associated with 3D-TS and 3D-GLS (r = − 0.819, p ≤ 0.001 for 3D-TS, p = − 0.477, r < 0.001, p = 0.001 for 3D-GLS). In this single vendor study age and gender-specific normative LV 3D-TS values were reported for healthy adult caucasians. In a significant proportion of the subjects 3D-STE was not feasible, but when feasible, 3D-STE shows excellent association with LVEF, and is therefore a promising novel modality for the assessment of the myocardial function, provided that issues of limited feasibility and temporal resolution are addressed

    In-depth echocardiographic analysis of left atrial function in healthy adults using speckle tracking echocardiography and volumetric analysis

    Get PDF
    Purpose: Left atrial (LA) dilatation is predictive for complications in a multitude of cardiac diseases; therefore, adequate assessment is essential. Technological advances have made it possible to quantify LA function with Speckle Tracking Echocardiography (STE); however, there are currently no recommendations for normal values with regard to LA function. We aimed to assess LA myocardial and volumetric function in a healthy cohort and investigate correlations with baseline characteristics. Methods: This prospective cohort study included 147 (aged 20–72) healthy individuals and assessed LA volumetric function using maximum, minimum and pre-a-wave volumes and myocardial function using reservoir function using peak strain in LA relaxation (LA-strain), conduit function using peak strain rate in early LA contraction (LA-SRe) and pump function using peak strain rate in late LA contraction (LA-SRa). Results: Mean LA-strain was 39.7 ± 6.2%, LA-SRe −2.78 ± 0.62 s−1 and LA-SRa −2.56 ± 0.62 s−1. Subjects were divided into 5 age decades (each 50% female). LA-strain and LA-SRe were lower in the oldest groups, whereas LA-SRa was higher. LA-SRa was higher in males(−2.69 ± 0.68 s−1 vs −2.42 ± 0.52 s−1). Age-specific values are provided. Age proved to be an independent predictor for LA-SRa after correction for blood pressure and heart rate. LA expansion index and passive emptying fraction decreased with age, while active emptying fraction increased with age. LA maximum volume did not increase with age. Conclusion: This study provides normal values for the three phasic functions of the LA, assessed with STE and volumetric function. Our results suggest the need for age-specific reference ranges, and normal values for this cohort have been calculated

    Influence of age and sex on left ventricular diastolic strain analysis

    Get PDF
    Speckle tracking analysis (STE) of the left ventricle offers a new method to assess left ventricular (LV) diastolic function. LV diastolic strain measurements offer a non-invasive, global and direct measure of LV diastolic function. However, there is little data on normal values and the influence of anthropomorphic factors which is crucial in clinical practice for new techniques. The aims of this study were to formulate reference values for LV diastolic strain rate, elucidate effects of age and sex on LV diastolic strain analysis and compare STE measurements with conventional LV diastolic measurements. One-hundred-forty-seven healthy subjects aged 20–72 years (≥ 28 subjects per age decade) were prospectively included (Mean age 44 ± 13.7 years, 50% female) and examined with electrocardiography and 2D-echocardiography, including speckle tracking. Left ventricular peak early diastolic strain rate (Sre) was measured in the apical windows, using STE. Men had significantly lower LV Sre values than women (1.02 ± 0.22 vs. 1.18 ± 0.23, p value < 0.001). Left ventricular Sre was inversely associated with age, with values decreasing with ageing. An inverse relation was also found with blood pressure and body surface area. Linear regression analysis showed that LV Sre was independently associated with both age and sex. A multivariable linear regression analysis for LV Sre with conventional LV diastolic variables accounted for 70.9% of the variation of LV Sre, showing good model performance. Reference values for LV Sre are reported and found to be both age- and sex-dependent. Therefore we recommend age- and sex-specific references values to be used in daily clinical practice

    Quantitative assessment of systolic left ventricular function with speckle-tracking echocardiography in adult patients with repaired aortic coarctation

    Get PDF
    Despite successful aortic coarctation (CoA) repair, systemic hypertension often recurs which may influence left ventricular (LV) function. We aimed to detect early LV dysfunction using LV global longitudinal strain (GLS) in adults with repaired CoA, and to identify associations with patient and echocardiographic characteristics. In this cross-sectional study, patients with repaired CoA and healthy controls were recruited prospectively. All subjects underwent echocardiography, ECG and blood sampling within 1 day. With speckle-tracking echocardiography, we assessed LV GLS on the apical four-, three- and two-chamber views. We included 150 subjects: 75 patients (57 % male, age 33.4 ± 12.8 years, age at repair 2.5 [IQR: 0.1–11.1] years) and 75 healthy controls of similar sex and age. LV GLS was lowe

    Exploring the Prognostic Value of Novel Markers in Adults With a Systemic Right Ventricle

    Get PDF
    Background-—Adults with a systemic right ventricle (sRV) have a high risk of cardiac complications. This study aimed to identify prognostic markers in adults with sRV based on clinical evaluation, echocardiography, and blood biomarkers. Methods and Results-—In this prospective cohort study, consecutive clinically stable adults with sRV caused b

    Echocardiographic parameters of severe pulmonary regurgitation after surgical repair of tetralogy of Fallot

    Get PDF
    Aims: Reliable evaluation of the severity and consequences of pulmonary regurgitation (PR) in patients with repaired tetralogy of Fallot (TOF) is crucial to timely identify the need for pulmonary valve intervention. We aimed to identify the accuracy of echocardiographic parameters to differentiate between moderate and severe PR, using phase contrast cardiac magnetic resonance imaging (CMR) as gold standard. Methods and results: In this cross-sectional study, 45 TOF patients with both echocardiographic and CMR measurements of PR were enrolled. All quantitative and semiquantitative echocardiographic measurements such as pressure half time (PHT), Color flow jet width (CFJW), ratio CFJW/right ventricle outflow tract (RVOT) diameter, PR index and the presence of early termination of the PR jet, end-diastolic antegrade flow and diastolic backflow in main pulmonary artery (MPA), and PA branches correlated significantly with PR fraction on CMR. Qualitative assessment with color flow on echocardiography overestimated PR Multivariate linear regression analysis identified the ratio of CFJW/RVOT diameter and PHT as independent predictors of PR fraction. Accuracy of echo parameters was tested to differentiate between mild-to-moderate and severe PR Combining different echocardiographic parameters increased sensitivity and specificity. The addition of diastolic flow reversal in the PA branches to PHT below 167 milliseconds increased the NPV from 87% to 89% and PPV from 62% to 76%. Conclusions: Comparison with CMR confirms that echocardiographic parameters are reliable in predicting PR severity. Combined measurement of diastolic flow reversal in the pulmonary artery branches and PHT is reliable in the detection of severe PR in the follow-up of TOF patients

    Left ventricular global longitudinal strain in bicupsid aortic valve patients: head-to-head comparison between computed tomography, 4D flow cardiovascular magnetic resonance and speckle-tracking echocardiography

    Get PDF
    Left ventricular global longitudinal strain (LVGLS) analysis is a sensitive measurement of myocardial deformation most often done using speckle-tracking transthoracic echocardiography (TTE). We propose a novel approach to measure LVGLS using feature-tracking software on the magnitude dataset of 4D flow cardiovascular magnetic resonance (CMR) and compare it to dynamic computed tomography (CT) and speckle tracking TTE derived measurements. In this prospective cohort study 59 consecutive adult patients with a bicuspid aortic valve (BAV) were included. The study protocol consisted of TTE, CT, and CMR on the same day. Image analysis was done using dedicated feature-tracking (4D flow CMR and CT) and speckle-tracking (TTE) software, on apical 2-, 3-, and 4-chamber long-axis multiplanar reconstructions (4D flow CMR and CT) or standard apical 2-, 3-, and 4-chamber acquisitions (TTE). CMR and CT GLS analysis was feasible in all patients. Good correlations were observed for GLS measured by CMR (− 21 ± 3%) and CT (− 20 ± 3%) versus TTE (− 20 ± 3%, Pearson’s r: 0.67 and 0.65, p 0.61, p < 0.001). Feature-tracking GLS analysis is feasible using the magnitude images acquired with 4D flow CMR. GLS measurement by CMR correlates well with CT and speckle-tracking 2D TTE. GLS analysis on 4D flow CMR allows for an integrative approach, integrating flow and functional data in a single sequence. Not applicable, observational study
    corecore