8 research outputs found

    Contrast-to-noise ratios and thickness-normalized, ventilation-dependent signal levels in dark-field and conventional in vivo thorax radiographs of two pigs

    Get PDF
    Lung tissue causes significant small-angle X-ray scattering, which can be visualized with grating-based X-ray dark-field imaging. Structural lung diseases alter alveolar microstructure, which often causes a dark-field signal decrease. The imaging method provides benefits for diagnosis of such diseases in small-animal models, and was successfully used on porcine and human lungs in a fringe-scanning setup. Micro- and macroscopic changes occur in the lung during breathing, but their individual effects on the dark-field signal are unknown. However, this information is important for quantitative medical evaluation of dark-field thorax radiographs. To estimate the effect of these changes on the dark-field signal during a clinical examination, we acquired in vivo dark-field chest radiographs of two pigs at three ventilation pressures. Pigs were used due to the high degree of similarity between porcine and human lungs. To analyze lung expansion separately, we acquired CT scans of both pigs at comparable posture and ventilation pressures. Segmentation, masking, and forward-projection of the CT datasets yielded maps of lung thickness and logarithmic lung attenuation signal in registration with the dark-field radiographs. Upon correlating this data, we discovered approximately linear relationships between the logarithmic dark-field signal and both projected quantities for all scans. Increasing ventilation pressure strongly decreased dark-field extinction coefficients, whereas the ratio of lung dark-field and attenuation signal changed only slightly. Furthermore, we investigated ratios of dark-field and attenuation noise levels at realistic signal levels via calculations and phantom measurements. Dark-field contrast-to-noise ratio (CNR) per lung height was 5 to 10% of the same quantity in attenuation. We conclude that better CNR performance in the dark-field modality is typically due to greater anatomical noise in the conventional radiograph. Given the high physiological similarity of human and porcine lungs, the presented thickness-normalized, ventilation-dependent values allow estimation of dark-field activity of human lungs of variable size and inspiration, which facilitates the design of suitable clinical imaging setups

    Optimization of tube voltage in X-ray dark-field chest radiography

    Get PDF
    Grating-based X-ray dark-field imaging is a novel imaging modality which has been refined during the last decade. It exploits the wave-like behaviour of X-radiation and can nowadays be implemented with existing X-ray tubes used in clinical applications. The method is based on the detection of small-angle X-ray scattering, which occurs e.g. at air-tissue-interfaces in the lung or bone-fat interfaces in spongy bone. In contrast to attenuation-based chest X-ray imaging, the optimal tube voltage for dark-field imaging of the thorax has not yet been examined. In this work, dark-field scans with tube voltages ranging from 60 to 120 kVp were performed on a deceased human body. We analyzed the resulting images with respect to subjective and objective image quality, and found that the optimum tube voltage for dark-field thorax imaging at the used setup is at rather low energies of around 60 to 70 kVp. Furthermore, we found that at these tube voltages, the transmission radiographs still exhibit sufficient image quality to correlate dark-field information. Therefore, this study may serve as an important guideline for the development of clinical dark-field chest X-ray imaging devices for future routine use

    Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography

    Get PDF
    The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-to-noise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms. The projected area in the object plane of the inflated lung was measured in dark-field images to quantify the collapse of lung parenchyma due to a pneumothorax. Means and standard deviations for lung sizes and signal intensities from dark-field and transmission images were tested for statistical significance using Student’s two-tailed t-test for paired samples. The contrast-to-noise ratio between the air-filled pleural space of lateral pneumothoraces and lung tissue was significantly higher in the dark-field (3.65 ± 0.9) than in the transmission images (1.13 ± 1.1; p = 0.002). In case of dorsally located pneumothoraces, a significant decrease (−20.5%; p > 0.0001) in the projected area of inflated lung parenchyma was found after a pneumothorax was induced. Therefore, the detection of pneumothoraces in x-ray dark-field radiography was facilitated compared to transmission imaging in a large animal model

    Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography

    Get PDF
    The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-tonoise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms. The projected area in the object plane of the inflated lung was measured in dark-field images to quantify the collapse of lung parenchyma due to a pneumothorax. Means and standard deviations for lung sizes and signal intensities from dark-field and transmission images were tested for statistical significance using Student's two-tailed t-test for paired samples. The contrast-to-noise ratio between the air-filled pleural space of lateral pneumothoraces and lung tissue was significantly higher in the dark-field (3.65 +/- 0.9) than in the transmission images (1.13 +/- 1.1;p = 0.002). In case of dorsally located pneumothoraces, a significant decrease (-20.5%;p > 0.0001) in the projected area of inflated lung parenchyma was found after a pneumothorax was induced. Therefore, the detection of pneumothoraces in x-ray dark-field radiography was facilitated compared to transmission imaging in a large animal model

    In-vivo X-ray Dark-Field Chest Radiography of a Pig

    Get PDF
    X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the first in-vivo XDF full-field chest radiographs (32 x 35 cm(2)) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 mu Sv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking

    X-ray dark-field imaging of the human lung-A feasibility study on a deceased body

    Get PDF
    Disorders of the lungs such as chronic obstructive pulmonary disease (COPD) are a major cause of chronic morbidity and mortality and the third leading cause of death in the world. The absence of sensitive diagnostic tests for early disease stages of COPD results in under-diagnosis of this treatable disease in an estimated 60-85% of the patients. In recent years a grating-based approach to X-ray dark-field contrast imaging has shown to be very sensitive for the detection and quantification of pulmonary emphysema in small animal models. However, translation of this technique to imaging systems suitable for humans remains challenging and has not yet been reported. In this manuscript, we present the first X-ray dark-field images of in-situ human lungs in a deceased body, demonstrating the feasibility of X-ray dark-field chest radiography on a human scale. Results were correlated with findings of computed tomography imaging and autopsy. The performance of the experimental radiography setup allows acquisition of multi-contrast chest X-ray images within clinical boundary conditions, including radiation dose. Upcoming clinical studies will have to demonstrate that this technology has the potential to improve early diagnosis of COPD and pulmonary diseases in general

    Contrast-to-noise ratios and thickness-normalized, ventilation-dependent signal levels in dark-field and conventional in vivo thorax radiographs of two pigs.

    Get PDF
    Lung tissue causes significant small-angle X-ray scattering, which can be visualized with grating-based X-ray dark-field imaging. Structural lung diseases alter alveolar microstructure, which often causes a dark-field signal decrease. The imaging method provides benefits for diagnosis of such diseases in small-animal models, and was successfully used on porcine and human lungs in a fringe-scanning setup. Micro- and macroscopic changes occur in the lung during breathing, but their individual effects on the dark-field signal are unknown. However, this information is important for quantitative medical evaluation of dark-field thorax radiographs. To estimate the effect of these changes on the dark-field signal during a clinical examination, we acquired in vivo dark-field chest radiographs of two pigs at three ventilation pressures. Pigs were used due to the high degree of similarity between porcine and human lungs. To analyze lung expansion separately, we acquired CT scans of both pigs at comparable posture and ventilation pressures. Segmentation, masking, and forward-projection of the CT datasets yielded maps of lung thickness and logarithmic lung attenuation signal in registration with the dark-field radiographs. Upon correlating this data, we discovered approximately linear relationships between the logarithmic dark-field signal and both projected quantities for all scans. Increasing ventilation pressure strongly decreased dark-field extinction coefficients, whereas the ratio of lung dark-field and attenuation signal changed only slightly. Furthermore, we investigated ratios of dark-field and attenuation noise levels at realistic signal levels via calculations and phantom measurements. Dark-field contrast-to-noise ratio (CNR) per lung height was 5 to 10% of the same quantity in attenuation. We conclude that better CNR performance in the dark-field modality is typically due to greater anatomical noise in the conventional radiograph. Given the high physiological similarity of human and porcine lungs, the presented thickness-normalized, ventilation-dependent values allow estimation of dark-field activity of human lungs of variable size and inspiration, which facilitates the design of suitable clinical imaging setups
    corecore